HEATIT
Z-DIN 616 Ver 2021-A
Firmware 0.15
01.02.2021
Installers manual
1. INTRODUCTION
The Heatit Z-DIN 616, which is built upon the wireless Z-Wave
communication protocol, has 6 relay driven outputs and 6 digital
inputs. The unit is a multi-purpose Z-Wave I/O module, which can be
used for many applications. For example, the Heatit Z-DIN 616 provides
the possibility to control other systems via the Z-Wave network, by
utilizing the 6 outputs as a kind of hand-over function to another
automation system.
The relay outputs (controlled through the Z-Wave network) are suitable
for switching up to six 230VAC loads. In connection with simultaneous
connection to SELV (Safety Extra Low Voltage) and 230VAC power
circuits for relay outputs, relays must be considered as two groups,
where the first group includes output 1 to 3 and the second group
includes outputs 4 to 6. This ensures complete separation between
the SELV and 230VAC circuits. If one of the relays in the group is
connected to a SELV circuit, the remaining outputs are not allowed to
be connected to 230VAC or another circuit which is not a SELV circuit.
For example, the relay outputs of the Heatit Z-DIN 616 module can be
used to control the 230Vac power supply outlet, making it possible
to turn on and disconnect the electrical outlets directly through the
Z-Wave network. For safety reasons, however, it is not recommended
to use the Heatit Z-DIN 616 to connect electrical outlets that are
normally used for hazardous tools and machinery.
The 6 digital inputs of the Heatit Z-DIN 616 are useful for various
purposes, where potential-free contacts or Open Collector outputs
may be connected. The inputs may be configured to different trigger
modes; leading edge, trailing edge or level triggered. The Heatit Z-DIN
616’s inputs may be programmed to control other Z-Wave devices
when the inputs are activated, by sending Z-Wave commands over the
Z-Wave network to e.g. Z-Wave relay modules, dimmer units etc.
Heatit Z-DIN 616 allows sending different types of Z-Wave commands
by utilizing the different association groups for the 6 inputs. In addition,
the Heatit Z-DIN 616 also acts as a repeater, thus extending the range
of the Z-Wave network. By default, the Heatit Z-DIN 616s inputs and
outputs are set to operate as toggle-relays. Input 1 controls the output
1, input 2 controls the output 2, etc. This functionality can be modified
via the configuration parameters 3-8 and 13-18.
2. BEHAVIOR WITHIN THE Z-WAVE™ NETWORK
This device may be operated within any Z-Wave network with
Z-Wave-certified devices from other manufacturers. All non-battery-
operated nodes within the network will act as repeaters regardless of
manufacturer to increase the reliability of the network. On delivery, the
device does not belong to any Z-Wave network.
The device needs to be added to an existing network to communicate
with the other devices within it. Devices may also be removed from
a network. The add/remove processes are initiated by the primary
controller of the Z-Wave network.
3. INSTALLATION
Installation must be done by a qualified electrician in accordance with
the National Building codes. Before installation, disconnect any power
to the device mains. During installation of the device, power to the
device must be disconnected AT ALL TIMES!
The Heatit Z-DIN 616 must be connected to a 24 Volt AC or DC power
supply via the terminals labeled ”Vin. The polarity is of no importance.
The supply must be dimensioned to allow the supplied module with
enough power to enable all relays to be activated. Regarding power
consumption: see the technical details section.
3.1 Relay outputs
The 6 outputs of the Heatit Z-DIN 616 module consist of 1-pole SPST
connectors (Single-Pole Single-Throw).
As default the outputs are configured to be controlled by its
corresponding input (output 1 is controlled by input 1, etc.). This
functionality is changeable via configuration parameter 13 to 18.
3.2 Inputs
The digital inputs of the Heatit Z-DIN 616 module can be connected
to different types of control signals - switches, relays, open-collector
outputs, etc.
The inputs IN1, IN2, IN3, IN4, IN5 and IN6 which operates as active low,
are pr. default pulled up to 3V DC and must be pulled low in order to
work, by mounting e.g. a contact between [IN1..IN6] and 0V. The inputs
24V AC/DC
230V AC
230V AC
01
NO
01
C
02
NO
02
C
03
NO
03
Vin Vin IN1 IN2 IN3 0V C
IN4 0V IN5 04
0V IN6 0V NO
04
C
05
NO
05
C
06
NO
06
C
Z-DIN 616
Belastning
NO C
Load


Produktspezifikationen

Marke: Heatit
Kategorie: Nicht kategorisiert
Modell: Z-DIN 616
Produktfarbe: Grau
Stromverbrauch (Standardbetrieb): 0.6 W
Abmessungen (BxTxH): 105 x 60 x 85 mm
Nachhaltigkeitskonformität: Ja
Nachhaltigkeitszertifikate: CE, RoHS
Maximum Innenabstand: 40 m
Anzahl der Pole: 1
DIN-Schienen-Montage: Ja
AC-Ausgangsspannung: 250/360 V