Hager VM11214SPD Bedienungsanleitung

Hager Schalten VM11214SPD

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hager VM11214SPD (3 Seiten) in der Kategorie Schalten. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 1
Consumer nit U
Design 30 Switch
Disconnector Incomer
with SPD
For the distribution of power in a residential
application, conforming to BS EN 61439-3
including Annex ZB (16kA rating).
Design 30 is the enhanced board for use in applications where the
consumer unit is located in a living area of the dwelling.
The range of consumer units with a 100A rated current (InA) have
been designed for installations where the upstream overcurrent
protection device (OCPD) is rated at 100A or below.
Design 0 consumer unit is an ntry level board esigned or all 1 e d f
applications and allows compliance with S 7671:2018; B
Regulation 21.1.201 within domestics (household) applications consumer 4
units and similar assemblies shall comply with S EN 61439-3 and hall B s
have their enclosure manufactured rom a on-combustible material. f n
Regulation 11.3.3 additional protection y means of a 0mA RCD s 4 b 3 i
provided y RCBOs. b
Regulation 14.1&2 segregation f circuits to avoid anger and minimise 3 o d
inconvenience in he event of a ault. t f
Regulation 22.6.202 protection f wiring concealed n walls or partitions. 5 o i
Regulation 31.3.3 Selection f appropriate RCD. Type A CBOs can 5 o R
d t petect and respond o both AC and ulsating DC components.
Regulation 36.4.3.2 & 36.4.202 overload protection f switches and 5 5 o
R iCCBs. For installations where the upstream overcurrent protection s less
than r equal to 100 A. o
Regulation 443.4 Protection st transient over voltages, provided by again
factory fitted type 2 SPD.
Description
Size Cat ref.
Cat ref.
with Knockouts
8 Way 100A Switch Disconnector Incomer with Factory Fitted SPD 4 VM108SPD VM108KSPD
12 Way 100A Switch Disconnector Incomer with Factory Fitted SPD 5 VM112SPD VM112KSPD
18 Way 100A Switch Disconnector Incomer with Factory Fitted SPD 7 VM118SPD VM118KSPD
8 + 10 Way Dual Row 100A Switch Disconnector Incomer with Factory Fitted SPD 4(2) VM10810SPD VM10810KSPD
12 +14 Way Dual Row 100A Switch Disconnector Incomer with Factory Fitted SPD 5(2) VM11214SPD VM11214KSPD
16 + 20 Way Dual Row 100A Switch Disconnector Incomer with Factory Fitted SPD 7(2) VM11820SPD VM11820KSPD
VM108SPD
Features & Benefits
- Cable clamp - Secures supply cables on entry to main incoming
device preventing any movement being transmitted through metertails
to device
- Square cable entry points top and bottom for use with cable trunking
(references available with or without knockouts)
- Rear Knockouts for ease of cable entry – Cable protector plate
provided
- Rigid top wall – Enhances rigidity to prevent distortion when removing
knockouts
- Locate and hold cover - allows use of both hands whilst xing cover
- Front cover retained screws – Prevents loss during installation
- Full metal DIN railSecure and stable attachment of devices
- Quick release clip on MCB/RCBO – Allows removal of MCB/RCBO
with busbar still in place
- Optimised cabling space DIN rail position allows maximum cabling
space
- Top mounted terminal rail makes the wiring of the neutral and earth
connections neat and simple.
- Health and Safety lock allows the door to be secured with circuits
isolated during construction (via accessory, see overleaf).
- Torque settings displayed inside front cover so they’re easily
accessible by the electrician.
- Lockable front door via an accessory (see overleaf).
Fa fitte type surge protectionctory d 2
-
Design 0 3
Switch isconnector ncomer onsumer nit D I C U with SPD
Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 2
Technical Characteristics
Standards BS EN 61439-3
Classication Consumer Unit
Rated & Operational Voltage (Un/Ue) 230V a.c 50 Hz
Rated Insulation Voltage (Ui) 320V a.c. 50Hz
Rated Frequency (fn) 50 Hz
Rated impulse withstand voltage (Uimp) 4kV
Rated Current of the Assembly (Ina) 63A/100A
Rated Current of an Outgoing Circuit I
nC RCBO A1**G- A - 45A (Marked Rated Current on Device) AD 40
RCBO - 6A - 32A (Marked Rated Current on Device)ADA3**G
Rated Conditional Short Circuit of the Assembly (I
cc) Annex ZB: 16kA rms at 250V, power factor 0.6 with equipment and arrange-
ments specied in Hager's technical documentation/catalogue
Protection against electric shock Consumer Unit shall be installed in an electrical system conforming to IEC
60364 / BS 7671
Rated Diversity Factor (RDF) / Values of assumed loading 2 Way to 3 Way - 0.8, 4 Way to 5 Way - 0.7, 6 Way to 9 Way - 0.6, 10 Way and
above - 0.5
Note: RDF only applies to continuously and simultaneously loaded circuits.
In principle, this means adjacent circuit breakers having a load on time exceeding 30 minutes or where a load not exceeding 30 minutes has an 'off' time less than
the 'on' time will need to have the rated diversity factor applied as indicated.
Pollution Degree 2
Types of System Earthing for which the assembly is designed TNC-S and TN-S when installed in an electrical system conforming to BS 7671TT,
Intended locations Indoor use only
Stationary assembly
Degree of protection IP2XC with door open / closed and full compliment of devices / blanks tted.
Note: Where cables are installed through the top wall of the enclosure, gaps of
IP4X to be maintained.
Intended use Intended for use in domestic (residential) or similar premises
Electromagnetic compatibility (EMC) classication EMC environment B
External design Wall mounted, surface type, enclosed assembly.
Mechanical impact protection IK05
Type of construction Fixed parts
Incoming Line/Neutral terminal (80 - 100A board) 50mm²
Incoming Line/Neutral terminal (63A board) 25mm²
Incoming Earth Terminal 16mm²
Warranty - Hager undertakes to replace or repair at its discretion products should they become inoperable within the time periods as stated. - 2 Years
Height
Width
Depth
Design 30 Dimensions (mm)
Enclosure Size
4 5 7
Height 240 240 240
Width 293 364 472
Depth 102.5 102.5 102.5
Number of Knockouts
*Top Face 30 x 25 (mm) 2 2 2
*Top Face 40 x 30 (mm) 44 6
Back 100 x 50 (mm) 13 3
*Bottom Face 30 x 25 (mm) 44 5
Accessories
Cable protector plate Provides protection for cables entering from the rear of the board VM02CE
Health and safety lock Provides the ability to lock the consumer unit during the installation process VMHBL
Design 30 door locking kit Allows the board to be lockable VMLOCK
Grommet strip For protecting cables against damage when entering the board VM05GS
Rear stand off plates To stand consumer unit off wall allowing surface mounted cables to enter through rear of unit. VM01SP
Devices
Single Pole, Single Mod RCBO 6kA, 40A - 45A Type A ADA1**G
Single Pole, Single Mod Reduced Height RCBO 6kA, 6A - 32A Type A ADA3**G
* References with a ‘K’ sufx feature top and bottom square knockouts.
Design 0 3
Switch isconnector ncomer onsumer nit D I C U
with SPD
Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 3
Surge protection devices
Consumer units with SPD in the part reference come with a Type 2 (T2) surge protection device. All connections to and
from the surge protection device are made at the factory. The phase is protected by a Metal Oxide Varistor (MOV) and the
neutral by a spark gap device. The Metal Oxide Varistor will degrade each time it deals with high voltage or
electromagnetic disturbances, when it is end of life the flag will turn red and the cartridge will require to be changed. At
this point the cartridge will fail open circuit and the device will no longer provide surge protection. Simply remove the
cartridge and replace with a new cartridge (SPD015D). The rest of the installation will remain unaffected.
To remove a cartridge when the flag is red
Position of SPD in installation
Overcurrent protection (F1) is provided by the upstream
over current protection device (OCPD) which for a
consumer unit is generally the service cut-out fuse.
SPD Characteristics
Design 0 3
Switch Disconnector ncomer onsumer nit I C U
with SPD


Produktspezifikationen

Marke: Hager
Kategorie: Schalten
Modell: VM11214SPD

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager VM11214SPD benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalten Hager

Bedienungsanleitung Schalten

Neueste Bedienungsanleitung für -Kategorien-