User’s Manual
For Model
Aero-551
(Rev. A)
Document:551-100 Rev A
LOG OF REVISIONS
REV
NO.
PAGE
NO.
DATE
DESCRIPTION
APPROVED
Orig.
1
thru 5
12/4/06
Initial Release
ASH VIJ
A
2 and 3
10/22/06
Deleted word 553
from Page 2 and 3
and updated
Installation
drawing Rev. A
ASH VIJ
CO Guardian LLC
1951 Airport Dr
Tucson AZ 85706
2
Tel 520-889-1177 Tel 800-639-7139 Fax 520-889-8249
Email:support@coguardian.com www.coguardian.com
Background
Model 551 is a CO Detector that Display CO Level between 10PPM
(Parts per Million) to 999PPM. The detector consists of one
Red button that is used to test and silence the alarm. Every
time the unit is turned on or reset button is pressed in a non
alarm condition, the will test the entire circuit for
integrity. If the unit alarms, the unit can be silenced by
pressing the reset button. The lights and display continue Red
displaying till CO goes below 10 PPM.
Installation
Install Aero-551 per CO Guardian installation drawing number
01-551-01-Rev. A (Or later revision) for hardware and wiring
diagram installation.
SELF TEST SEQUENCE AT STARTUP:
When you power up the Aero-551, you will notice the following test
sequence:
The screen will show the word “CO Guardian, short beep and current
time will display. Internally in the background, the system will
check the sensor for 30 seconds and all internal components. If any
components fail, the display will show the word “Failed” and the unit
must be returned for repair.
CARBON MONOXIDE LEVEL INDICATION:
DISPLAY : CO LEVEL
Aero 551 can detect Carbon Monoxide from as low as 10 PPM. Aero 551 will
trigger an alarm for CO long before the pilot / passengers can be affected
by exposure to CO.
The effect of CO level on the human body is linked to the duration of
exposure to CO. Our units are designed to set off CO alarms in progressively
shorter durations as the concentration of CO increases. The intention is to
prevent a false alarm when the CO level poses no danger, but at the same
time ensure full protection when the level starts becoming dangerous.
3
Note: Picture of 552 Shown accidentally). 551 does not have any blue
buttons.
LAYOUT OF BUTTONS / CONTROLS:
The Aero 551 features a 1.75 x 1 inch LCD display. The display is backlit
continuously. There are basically 1 buttons which can controls the
detector. : The red button at the top ( marked RST ) is the Test / Re-set
button which can be used to test or re-set the unit.
CO LEVEL ALARM ACTIVATION:
CO level alarm activated after: in PPM (Parts per million)
PPM
11 - 50 Display only No alarm
50 – 70 04 minutes
70-100 03 minutes
200 02 minutes
300> 01 minutes
NOTE: Concentration of CO in air Inhalation time and toxic developed
50 parts per million (ppm) Safety level as specified by the FAA
200 PPM Slight headache within 2-3 hours
400 PPM Frontal headache within 1-2 hours
800 PPM Dizziness, nausea, convulsions within 45 minutes