Gossen Metrawatt PROFITEST PV Bedienungsanleitung

Gossen Metrawatt Messung PROFITEST PV

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Gossen Metrawatt PROFITEST PV (36 Seiten) in der Kategorie Messung. Dieser Bedienungsanleitung war fĂĽr 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
Operating Instructions
PROFITESTď‚˝PV
Peak Power Meter and Curve Tracer for PV Modules and
Generators up to 1000 V DC, 20 A DC, 20 kW 3-349-633-03
3/3.16
2 GMC-I Messtechnik GmbH
Contents Page Contents Page
1 License Agreement .......................................................... 3
2 Introduction ...................................................................... 4
3 Use for Intended Purpose ................................................. 4
4 Safety Precautions ........................................................... 4
4.1 Safety Features and Precautions .....................................................4
5 Warnings .......................................................................... 5
6 Operating the PROFITEST PV ............................................ 6
6.1 Controls and Connectors ................................................................6
6.2 General Notes ...............................................................................6
6.3 Connecting Peripheral Devices .......................................................6
6.4 Power Supply ................................................................................7
6.5 Connection to a PC ........................................................................7
6.6 Connecting the Solar Generator ......................................................7
6.7 Measured Value Transducers for Temperature and
Irradiation ......................................................................................7
6.8 Switching the Instrument On ..........................................................8
6.9 Buttons .........................................................................................8
6.10 Measurement ................................................................................9
6.10.1 Entering Module, Customer and System Data ..................................9
6.10.2 Start Measurement ........................................................................9
6.10.3 Archive .........................................................................................9
6.10.4 Transfer ......................................................................................10
6.10.5 Results .......................................................................................10
6.11 Messages ...................................................................................10
7 1000 V / 32 A Load Disconnector ................................... 11
8 Influences on Measuring Accuracy ................................ 11
9 Installing PV Analyzer Transfer Software ....................... 12
10 Installing the USB Device Driver (CDM) .......................... 13
10.1 Installation via “Found New Hardware” ..........................................13
10.2 Uninstalling the CDM Driver ..........................................................14
11 Using PV Analyzer Transfer Software ............................ 15
11.1 The File Menu .............................................................................15
11.1.1 Open ..........................................................................................15
11.1.2 Save as ... ...................................................................................15
11.1.3 Browse .......................................................................................15
11.1.4 Export .........................................................................................16
11.1.5 Report .........................................................................................16
11.1.6 Analysis ......................................................................................17
11.1.7 Printer Setup ...............................................................................17
11.1.8 Exit .............................................................................................17
11.2 Edit .............................................................................................17
11.2.1 Cut .............................................................................................17
11.2.2 Copy ...........................................................................................17
11.2.3 Paste ..........................................................................................17
11.3 Extras .........................................................................................17
11.3.1 Start Measurement at the PROFITEST PV
(“Trace Curve” button). ................................................................17
11.3.2 Managing Files at the PROFITEST PV (“Data Transfer” button) ...18
11.3.3 Transfer Date and Time to the PROFITEST PV ..............................18
11.3.4 Continuous Measurement ............................................................18
11.3.5 Editing the PROFITEST PV Sensor Database .................................19
11.3.6
Managing Modules at the PROFITEST PV
(“Module List” button) ........................................................................19
11.3.7
Managing Measuring Tasks at the PROFITEST PV
(“Measuring Tasks” button) ................................................................19
11.3.8 Calculating Internal Series Resistance Rs ......................................19
11.3.9 Customer Database .....................................................................20
11.3.10 Module Database ........................................................................20
11.3.11 Settings ......................................................................................20
11.3.12 Setting Temperature Offset ..........................................................21
11.3.13 Firmware Update .........................................................................21
11.4 Using the Graphic Interface ..........................................................21
11.4.1 Measuring Points On/Off (“Measuring Points” button) ....................21
11.4.2 MPP On/Off (“Show MPP” button) ................................................21
11.4.3 Display Theoretical Curve On/Off ..................................................21
11.4.4 Display Characteristic STC Curve On/Off .......................................21
11.4.5 Power Display On/Off ...................................................................21
11.4.6 Key On/Off (“Key” button) .............................................................22
11.4.7 Stretch On /Off (“Max. Zoom” button) ...........................................22
11.4.8 To Clipboard (“Clipboard” button, main toolbar) .............................22
11.5 Results .......................................................................................22
11.6 Help ...........................................................................................22
11.6.1 Contents .....................................................................................22
11.6.2 Search ........................................................................................22
11.6.3 Using Help ..................................................................................22
11.6.4 Info .............................................................................................22
12 Technical Data ............................................................... 23
12.1 Unit of Measure ...........................................................................23
12.2 Sensor Connection Pin Allocations ................................................23
12.3 Computer Unit .............................................................................23
12.4 Display .......................................................................................23
12.5 Operation ....................................................................................23
12.6 Power Supply ..............................................................................23
12.7 Dimensions .................................................................................23
12.8 Operating Conditions ...................................................................23
12.9 Optionally Available .....................................................................23
13 List of Symbols Used in Formulas .................................. 24
14 Causes of Reduced Output and Yield ............................. 25
15 Characteristic IU Curves: Contexts ................................. 26
16 Sample Characteristic Curves from Actual
Practice (source: PVE) ..................................................... 29
17 Glossary ......................................................................... 30
18 Appendix A ..................................................................... 32
18.1 Charge Level Indicator for Integrated Rechargeable Battery ............32
18.2 Acoustic Signals ..........................................................................32
19 Maintenance and Recalibration ..................................... 33
19.1 Return and Environmentally Sound Disposal ..................................33
19.2 Recalibration ...............................................................................33
19.3 Repair and Replacement Parts Service
Calibration Center and Rental Instrument Service ..........................33
20 Product Support ............................................................. 34
GMC-I Messtechnik GmbH 3
1 License Agreement
The following conditions apply to the use of GMC-I Messtechnik
software by the end user, hereinafter referred to as “licensee”.
The subject matter of this agreement if the computer program
included on the data storage medium, the program description
and the instructions for use, as well as all other associated printed
materials, hereinafter referred to as “software”.
We draw the user’s attention to the fact that it is not possible, with
the current state-of-the-art, to produce computer software such
that it functions in an error-free fashion in all applications and
combinations. The subject matter of the license agreement is thus
once piece of software only, which is generally usable as set forth
in the program description and instructions for use.
For the duration of this agreement, GMC-I Messtechnik GmbH
grants you the non-exclusive personal right (hereinafter referred to
as “license”) to use the accompanying copy of GMC-I Messtech-
nik software on a single computer (i.e. with a single central pro-
cessing unit), and at a single location only. If this single computer
is a multi-user system, the right to use the software applies to all
users of the system.
As the licensee, you may transmit software in physical form (i.e.
stored to a data storage medium) from one computer to another,
on the condition that it will always be used on one computer at
any given point in time.
Any further use is impermissible.
The licensee is forbidden:
a) To forward the software or associated printed materials to any
third party, or otherwise make it accessible to any third party,
without prior written consent from GMC-I Messtechnik GmbH
b) To transfer the software from one computer to another via a
network or other data transmission lines
c) To modify, translate, reverse engineer, decompile or disas-
semble the software without prior written consent from
GMC-I Messtechnik GmbH
d) To produce other work derived from the software or to dupli-
cate the printed materials
e) To translate or modify it the printed materials, or to produce
other work derived from them
Upon purchasing the product, the licensee acquires ownership of
the physical data storage medium only, to which the software has
been recorded. Even in this case, the licensee does not acquire
any rights to the software. GMC-I MesstechnikGmbH reserves all
rights to the software, in particular regarding publication, duplica-
tion, editing and utilization rights.
The software and the associated printed materials are protected
by copyrights. Insofar as the software is not copy protected, you
are entitled to make a single backup copy for purposes of data
security. You are obligated to attach or record the copyright
notice of GMC-I Messtechnik to the backup copy. Any copyright
notice included in the software and registration numbers recorded
to it may not be removed. It is expressly prohibited to copy or oth-
erwise duplicate the software or the printed materials, either in
part or in their entirety, in their original or in any modified form, or
in any form involving mixing with, or inclusion in, other software.
The right to use the software can only be transferred to a third
party with prior written consent from GMC-I Messtechnik, and
only under the conditions set forth in this agreement. Giving away,
renting and loaning the software are expressly forbidden.
The license agreement is valid for an indefinite period of time. The
licensee’s right to use the software expires automatically without
notice in the event that he violates any of the conditions of this
agreement. Upon termination of the licensee’s right to use the
software, he is obligated to destroy the original data storage
medium, as well as all copies of the software, including any modi-
fied copies and the printed materials.
GMC-I Messtechnik draws attention to the fact that the licensee is
liable for all damages resulting from copyright violations incurred
by GMC-I Messtechnik due to any breach of the conditions of this
agreement committed by the licensee.
GMC-I Messtechnik is entitled to update the software at its own
discretion.
GMC-I Messtechnik is not obligated to automatically make any
software updates available to the licensee.
Guarantee:
a) GMC-I Messtechnik guarantees to the original licensee that, at
the time of delivery, the data storage medium to which the
software has been recorded, as well as the hardware supplied
with the software, demonstrate error-free material and work-
manship when used under normal operating conditions and
with normal maintenance.
b) In the event that the data storage medium or the hardware
delivered with it should be defective, the buyer is entitled to
demand replacement during the guarantee period of 6
months after delivery. The buyer must return the data storage
medium and any hardware supplied along with it to this end,
together with the backup copy, the printed materials and a
copy of the invoice to GMC-I Messtechnik.
c) If a defect as described in point b) is not eliminated within a
reasonable period of time by means of replacement, the buyer
is entitled to demand either a reduction of the purchase price
or cancellation of the sales contract at his own discretion.
d) GMC-I Messtechnik does not assume any liability for defects
in the software. In particular, GMC-I Messtechnik does not
guarantee that the software shall fulfill the buyer’s require-
ments and purposes, or that it functions together with other
software programs selected by the buyer. Responsibility for
correct selection and the consequences of use of the soft-
ware, as well as any intended or achieved results obtained
with the software, are borne by the buyer. The same applies
to the printed materials which accompany the software. If the
software is not generally usable in the spirit of the program
description and the instructions for use, the buyer has the
right to rescind the sales contract. GMC-I Messtechnik also
has the right to rescind the sales contract if such usability can-
not be restored at reasonable expense.
e) GMC-I Messtechnik assumes no liability for damages, unless
they result from gross negligence or malicious intent on the
part of GMC-I Messtechnik. Liability for gross negligence is
also excluded vis-Ă -vis merchants. Any liability resulting from
characteristics warranted by GMC-I Messtechnik remain unaf-
fected. Liability for consequential damages which are not cov-
ered by warranted characteristics is excluded.


Produktspezifikationen

Marke: Gossen Metrawatt
Kategorie: Messung
Modell: PROFITEST PV

Brauchst du Hilfe?

Wenn Sie Hilfe mit Gossen Metrawatt PROFITEST PV benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Messung Gossen Metrawatt

Bedienungsanleitung Messung

Neueste Bedienungsanleitung fĂĽr -Kategorien-