Gossen Metrawatt Metrahit H&E Car Bedienungsanleitung
Gossen Metrawatt
Multimeter
Metrahit H&E Car
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Gossen Metrawatt Metrahit H&E Car (28 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/28
Operating Instructions
METRA METRAHIT⏐27 and HIT⏐H+E CAR
METRA HIT 27M: Digital Multimeter and Milliohmmeter
METRA HIT 27I: Digital Multimeter, Milliohmmeter and Megohmmeter
METRA HIT H+E CAR: Mega Tester for Hybrid E-cars 3-349-207-02
15/2.19
2 GMC-I Messtechnik GmbH
1 Display (LCD)
2 ON|OFF key
Operating mode menu: open submenus / acknowledge entries
METRA HIT 27I: background illumination ON / OFF
3 DATA| CLEAR key for following functions: save measured value,
delete and MIN/MAX
Operating mode menu: Selection of individual menu items
against direction of flow / increase values
4 MAN|AUTO key for manual measuring range selection
Operating mode menu: Selection of individual menu items
in direction of flow, decrease values
5FUNC key for selecting functions, start key INS measurement
Operating mode menu: Exit menu level and return to a higher level/
exit parameters configuration without saving data
6 Rotary selector switch for measuring function
7 Connector jacks *
8 Connector jacks for mains power battery charger NA HIT 27
( )only with storage batteries inserted
*
⊥
Earthing input
S- Sense –, for 4-wire connection only with
Ω
/m
Ω
/m
Ω
@
1A
S+ Sense +, for 4-wire connection only with
Ω/
m
Ω
/m
Ω
@1A
V;
Ω
;
°
C, M
Ω
measurement input
Symbols used in the Digital Display
1 Main display with decimal point and polarity display
2 Auxiliary display with decimal point and polarity display
3 : Multimeter in continuous operation,
ON blinks at transmission frequency in transmission mode
4 REM: Memory mode operation, disappears after communication
via the interface is ended by means of key or switch operation
5 ZERO: Zero balancing
6 MAN: Manual measuring range selection
7 Unit of measure (if blinking, refer to chapter 11.2 on page 16 and
chapter 15 on page 26)
8 MIN/MAX: Display of smallest/largest recorded values
with time specification
9:Acoustic signal enabled,
beeper is activated for corresponding function
10 :
Low recharcheable battery voltage (< 3.3 V), recharge batteries
Standard Equipment
1
2
3
4
5
6
8
7
7
max. 600 V !
Type 27M 27I 27AS
27I Set
H+E
CAR
H+E
CAR
Set
Article Number M227A M227B M227C M227S M227T M227U
Instrument METRA HIT 27M 27I 27I 27I
H+E
CAR
H+E
CAR
3 size AA NiMH storage batteries
••••••
Measurement cable set
KS17-S KS17-S KS17-S KS17-2
— —
operating instructions ••••••
abbreviated operating instructions
••••••
GH18 protective rubber
cover with carrying strap green green green green orange orange
DAkkS calibration certificate
••••••
Charging unit NA HIT 27 — •••••
Kelvin clips KC4 (1 set = 2 each)
—•••— —
Kelvin prob. KC27 (1 set=2 each)
—— ———•
Hard case HC30 — — • • — —
Hybrid Diagnostic-Kit — — — — — •
1
10
9
64 53
7
8
2
GMC-I Messtechnik GmbH 3
Table of Contents
Page Page
1 Safety Features and Precautions ...............................4
2 Initial Start-Up ............................................................5
3 Selecting Measuring Functions and Measuring
Ranges .......................................................................6
3.1 Automatic Measuring Range Selection .....................................6
3.2 Manual Measuring Range Selection ......................................... 6
3.3 Quick Measurements .............................................................. 7
4 Triple Digital Display ..................................................7
5 Measured Value Storage ............................................8
5.1 Measured Value Storage – Key Function “DATA”
(Hold/Compare) ......................................................................8
6 Saving Minimum and Maximum Values
“MIN/MAX” with Time Stamp .....................................9
7 Voltage and Frequency Measurement ......................10
7.1 Voltage Measurement [V] ...................................................... 10
7.1.1 Zero Balancing in the 3 V DC Measuring Range ...................... 10
7.2 Frequency Measurement [Hz] ................................................ 10
8 Resistance and Diode Measurements ......................11
8.1 Resistance Measurement (2-wire connection) [Ω] .................. 11
8.1.1 Zero Balancing in the 300 Ω and 3 kΩ Measuring Ranges ..... 11
8.2 Continuity Test during Resistance Measurement .................... 12
8.3 Diode Measurements ........................................................... 12
9 Milliohm Measurement (4-Pole-Measurement) .......13
9.1 Compensation of Cable Resistance ........................................ 13
9.1.1 Measurement with Kelvin Probe KC27 ................................... 13
9.2 Thermovoltage Compensation ................................................ 13
9.3 Milliohm Measurement with 200 mA or 20 mA DC [mΩ] ........ 14
9.4 Milliohm Measurement with 1 A Pulsating Measuring
Current [mΩ@1 A]
(automatic thermovoltage correction in 3
…
300
m
Ω
range) ...........14
10 Temperature Measurement [°C] ..............................14
11 Insulation Resistance Measurement [MΩ@...V]
(METRA HIT 27I and METRA HIT H+E CAR only) ........15
11.1 Preparing for Measurement ................................................... 15
11.2 Insulation Resistance Measurement ....................................... 16
11.3 Ending the Measurement and Discharging .............................. 16
12 Using the Menus – from the Initial InFO Menu to
Operating and Measuring Parameters .....................17
12.1 Sampling rAtE ........................................................... 17
12.2 Saving Measured Values ....................................................... 17
12.2.1Memory Mode – DATA Key Function (see also chapter 5.1) ..... 17
12.2.2Memory Mode Operation – STORE Menu Function .................. 18
12.3 Querying Memory Occupancy – INFO MEMO/OCCUP ......... 18
12.4 Clearing the Memory – MEMO CLEAr ................................ 18
12.5 Activating the Default Values ................................................. 18
12.6 Transmission Mode Operation with RS 232 Interface .............. 19
13 Characteristic Values .....................................22
14 Maintenance ............................................................25
14.1 Storage Batteries and Batteries ............................................. 25
14.2 Fuses ................................................................................... 26
14.3 Housing ............................................................................... 26
14.4 Device Return and Environmentally Compatible Disposal ......... 26
15 Multimeter Messages .............................................. 26
16 Accessories .............................................................27
17 Repair and Replacement Parts Service,
Calibration Center* and Rental Instrument Service . 27
18 Guarantee ................................................................28
19 Product Support .......................................................28
20 Recalibration ............................................................28
Produktspezifikationen
Marke: | Gossen Metrawatt |
Kategorie: | Multimeter |
Modell: | Metrahit H&E Car |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Gossen Metrawatt Metrahit H&E Car benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Gossen Metrawatt
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
21 August 2024
21 August 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Velleman
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter EMOS
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
13 Oktober 2024
9 Oktober 2024
5 Oktober 2024
5 Oktober 2024
3 Oktober 2024