Gardena Comfort Pump 8500 Bedienungsanleitung

Gardena Wasserpumpe Comfort Pump 8500

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Gardena Comfort Pump 8500 (14 Seiten) in der Kategorie Wasserpumpe. Dieser Bedienungsanleitung war für 15 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/14
DGBFNLSDKFINNIEPPLHCZSKGRRUSSLOHR
SRB
BIH
UAROTRBGALESTLTLV
GARDENA
®
DBetriebsanleitung
Tauchpumpe / Schmutzwasserpumpe
GB Operating Instructions
Submersible Pump / Dirty Water Pump
FMode d’emploi
Pompe d’évacuation pour eaux claires /
Pompe d’évacuation pour eaux chargées
NL Instructies voor gebruik
Dompelpomp / Vuilwaterpomp
SBruksanvisning
Dränkbar pump / Spillvattenpump
DK Brugsanvisning
Dykpumpe / Dykpumpe til urent vand
FIN Käyttöohje
Uppopumppu / likavesipumppu
NBruksanvisning
Lensepumpe / Lensepumpe for
urent vann
IIstruzioni per l’uso
Pompa sommersa / Pompa sommersa
per acqua sporca
EManual de instrucciones
Bomba sumergible /
Bomba para aguas sucias
PInstruções de utilização
Bomba submersível /
Bomba para águas sujas
PL Instrukcja obsługi
Pompa zanurzeniowa /
Pompa do brudnej wody
HHasználati utasítás
Merьlхszivattyъ / Szennyvнzszivattyъ
CZ Návod k použití
Ponornй иerpadlo / kalovй иerpadlo
SK Návod na použitie
Ponornй иerpadlo / kalovй иerpadlo
GR Οδηγίες χρήσεως
Βυθιζμενη αντλία /
Αντλία Ακαθάρτων
RUS Инструкция по эксплуатации
Погружной насос /
Насос для сточных вод
SLO Navodilo za uporabo
Potopna иrpalka /
иrpalka za umazano vodo
HR Upute za uporabu
Potopna crpka / crpka za otpadnu vodu
SRB Uputstvo za rad
BIH Potopna pumpa / Pumpa za prljavu vodu
UA Інструкція з експлуатації
Заглибний насос /
насос для брудної води
RO Instrucţiuni de utilizare
Pompa submersibilă /
Pompг de apг murdarг
TR Kullanma Kılavuzu
Dalgıç Pompa / Kirli Su Pompası
BG Инструкция за експлоатация
Потопяема дренажна помпа /
Помпа за мръсна вода
AL Manual përdorimi
Pompë zhytëse / Pompë për ujë të pisët
EST Kasutusjuhend
Uputatav pump / Reoveepump
LT Eksploatavimo instrukcija
Panardinamas siurblys /
Purvino vandens siurblys
LV Lietošanas instrukcija
Iegremdējamais sūknis /
Netīrā ūdens knis
9000
aquasensor
Art. 1783
13000
aquasensor
Art. 1785
8500
aquasensor
Art. 1797
13000
aquasensor
Art. 1799
Intended use
Liquids to be pumped
Please note
GARDENA
Submersible Pump 9000 / 13000 aquasensor /
Dirty Water Pump 8500 / 13000 aquasensor
Translation of the original instructions from German.
Please read these operating instructions carefully and observe the notes given. Use the
instructions to familiarise yourself with the pump, its correct use, and the notes on safety.
AFor safety reasons, children under 16 as well as persons not familiar with these operating
instructions should not use this pump. Persons with reduced physical or mental abilities
may use the hedge trimmer only if they are supervised or instructed by a responsible
person.
vKeep these operating instructions in a safe place.
1. Applications Range of Your GARDENA Pump . . . . . . . . . . . . . . . . 11
2. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. Putting into Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Service / Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1. Applications Range of Your GARDENA Pump
GARDENA Pumps have been designed for private use around
your house and garden. They are predominantly destinated for
drainage after flooding, transfer of liquids, draining containers,
taking water from wells and shafts, draining boats and yachts
as well as for water aeration and circulation for a limited period
of time.
Liquids which can be handled by the GARDENA Pump are the
following: clean and contaminated water (max. particle size
submersible pumps = 5 mm / dirty water pumps = 30 mm) and
swimming pool water (prerequisite is the recommended dosage
of additives). Dirty water with solid particles such as sand or
stones leads to wear of the turbine and of the pump base.
The pumps are fully submersible (waterproof sealed) and can be
immersed in the liquid down to a depth of 7 m.
The GARDENA Pumps are not designed for continuous
operation (e.g. continuous circulating operation) in a pond.
Your pump’s life will be shortened correspondingly by such
operation.
Corrosive, easily combustible or explosive substances
(e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water
and waste water of toilets and urinals must not be pumped.
The temperature of the liquid handled should not exceed
35 °C.
Contents
11
GB
12
GB
2. Safety Instructions
Electrical Safety
According to DIN VDE (German Electrical
Engineers’ Association) 0100, submersible
pumps and dirty water pumps may only be
used in swimming pools, garden ponds,
and fountains if the pump is operated via a
residual-current device with a residual-current
rating of 30 mA.
The pump must not be operated when there
are persons in the swimming pool or garden
pond.
For safety reasons we recommend that you
always operate the pump via a residual-
current device (DIN VDE 0100-702 and
0100-738).
vPlease contact your electrician.
According to DIN VDE (German Electrical
Engineers’ Association) 0620, mains power
cables must not have a smaller cross-section
than the rubber-sheathed cables of the
designation H05 RNF (for Art. Nos. 1783 /
1797) or H07 RNF (for Art. Nos. 1785 / 1799).
The cable length must be at least 10 m.
Data indicated on the type plate must match
technical data of the mains supply.
vTake care that the electrical connections
are made within dry area, protected from
flooding.
vKeep mains plug dry.
Protect plug and power cable from heat, oil
and sharp edges.
DANGER ! Electric shock !
With a cut off mains plug, moisture can get into
electrical parts via the mains cable and cause a
short circuit.
VNever cut the mains plug off (e.g. to
feed through wall).
vDon’t use the power cable for plugging off.
The power cable or the float switch must not
be used for mounting or relocating the pump.
For submerging or lifting/securing the pump,
fix a rope to the pump’s carrying handle.
Extension cables must meet the requirements
of DIN VDE 0620.
In Austria
In Austria, according to ÖVE B/EN 60 555
part 1 to 3, pumps which are used in swim-
ming pools and garden ponds, and equipped
with firm power cable should be fed via an
ÖVE approved isolating transformer rated
voltage must not exceed 230 V.
In Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a
residual-current device.
Visual check
vBefore operating the pump, first make
a visual check, if there is any damage
of the pump (esp. regarding power cable
and plug).
vObserve the minimum water level and
the max. delivery height (see 8. Technical
Data).
DANGER ! Electric shock !
A damaged pump must not be used.
vIn case of damage, please have the pump
checked by our GARDENA Service Centre.
Manual operation
During manual operation, the pump must
be switched off as soon as all the liquid has
been pumped away.
vObserve the pump at all times during
manual operation.
Notes on use
Dry-running operation causes increased
wear and is to be avoided. Therefore, in man-
ual operation the pump must be immediately
unplugged when water fails to flow.
Avoid running of the pump for more than
10 min. against closed delivery side of the
pump.
Sand and other abrasive substances cause
increased wear and reduce the pump’s output.
Take care that the pump is located where
the inlet openings at the suction base are
obstructed neither completely nor partly.
Stand the pump on a brick if using in a pond.


Produktspezifikationen

Marke: Gardena
Kategorie: Wasserpumpe
Modell: Comfort Pump 8500
Gewicht: 4000 g
Produktfarbe: Black, Blue
Max. Förderhöhe: 6 m
Eintauchtiefe (max): 7 m

Brauchst du Hilfe?

Wenn Sie Hilfe mit Gardena Comfort Pump 8500 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wasserpumpe Gardena

Bedienungsanleitung Wasserpumpe

Neueste Bedienungsanleitung für -Kategorien-