Fully Automatic Upper Arm
Blood Pressure Monitor
Model Number: C02 / FB160
USER’S MANUAL
CONTENTS
1 Introduction and Intended Use .............................................................................................................. 2
2 Important Information on Blood Pressure and its Measurement .......................................................... 3
3 Components of your blood pressure monitor ....................................................................................... 5
4 Using your Monitor for the First Time ................................................................................................... 6
5 Measurement Procedure ...................................................................................................................... 8
6 Care and Maintenance ........................................................................................................................ 15
7 Warranty/Service................................................................................................................................. 15
8 Certifications ....................................................................................................................................... 16
9 Technical Specifications ..................................................................................................................... 16
10 EMC Declaration ................................................................................................................................. 16
2
1 Introduction and Intended Use
It enables reliable measurement of systolic and diastolic blood pressure as well as pulse through the
oscillometric method.
Before using, please read this instruction manual carefully and then keep it in a safe place.
1.1 Remember
-Only a health care professional is qualified to interpret blood pressure measurements.
This device is NOT intended to replace regular medical checkups.
Blood pressure readings obtained by this device should be verified before prescribing or making
adjustments to any medications used to control hypertension. Under no circumstances should YOU
alter the dosages of any drugs prescribed by your physician.
This monitor is intended for use by adults only. Consult with a physician before using this instrument
on a child.
In cases of irregular heartbeat, measurements made with this instrument should only be evaluated
after consultation with a physician.
Host products, including accessories, shall be processed in accordance with local regulations after
reaching the life cycle.
1.2 Warnings and Precautions
Warning:
The use of other accessories other than those specified or provided by the equipment
manufacturer may cause electromagnetic radiation to increase or decrease
electromagnetic immunity resulting in operational failure
Warning:
This system may fail to yield specified measurement accuracy if operated or stored in
temperature or humidity conditions outside the limits stated in the specifications
section of this manual.
Warning:
The separate ac adapter which is intended to connect USB interface of Blood
Pressure Monitor has not been evaluated according to IEC 60601 1. The safety of the -
product shall be reappraised when it power supply by a separate ac adapter.
Warning: The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
Warning:
The device is not suitable for use in the presence of flammable anesthetic mixtures
with air or with oxygen or nitrous oxide.
Warning:
The patient is an intended operator, the functions of monitoring blood pressure and
pulse rate can be safely used by patient. The routine clean and changing batteries
can be performed by the patient.
Warning:
This device can not be used together with hf surgical equipment.
Warning: Use of power adapters
1. Adapter: input 100 240V, 50/60hz output DC 5V 1A-
2. Do not to position the device to make it difficult to operate the disconnection
device while using adaptor.
3. Avoid usage in wet, moisture, high temperature, corrosive gas environments and
in direct sunlight.
Warning:
Too frequent measurements can cause injury to the PATIENT due to blood flow
interference.