22.32
22.3 (022.33/022.35)2 +
• Open Type Device - Pollution degree 2 Installation Environment
• Maximum Surrounding Air Temperature 50°C
• Minimum distance among modular contactors 9 mm
• Field Wiring Terminals:
Use 60/75°C copper conductor only and wire ranges
No. 10-12-18-24 AWG, Solid only
Terminal tightening torque 7.0 lb.in. (0.8 Nm)
• Suitable for use on a circuit capable of delivering not more than
5000 ARMS Symmetrical, 240 V ac, when protected by Listed
Cartridge Fuses, rated K5 Class (No Current Limiting, Non-Time
Delay, max 600 Vac, 30 A, 50 kA A.I.C.) or RK5 Class (Current
Limiting, Time Delay, max 600 Vac, 15 A, 50 kA A.I.C.) or equivalent
• For use in a circuit protected by Type1 or Type2 Surge Protective
Devices with “Max Voltage Protection” rating of 3.7 kVpk and
“Minimum Nominal Discharge Current” of 5 kA (at 6 kV)
022.33 022.35
022.33 2 NO (DPST- NO)
022.35 1 NO (SPST- NO) + 1 NC (SPST- NC)
Ith 6 A
AC15 700 VA
(230 V AC)
22.32.0. .x x0xxx x
UN ( - - - - - )V AC (50/60 Hz) / DC12 24 48 60 120 230
Umin- Umax (0.8-1.1)UN
P 2 VA / 2.2 W
22.32...x x0 22.32...x x0 22.32...x x03 5 4
25 A 440 V AC (EN 61095)
AC AC-7a (250 V) 6250 VA1/
AC AC-7b 10 A3/
AC5a (250 V) 15 A
AC15 (230 V AC) 1800 VA
(230 V AC) 1 kW
DC1 (30/11 220 /1)A0/ )V (25/5
AC-7c - (10 A - ... )22.32 4xx0
800 W (2000 W - )22.32... xx04
300 W (800 W - )22.32... xx04
CFL–LED 100 W (200 W - )22.32... xx04
(–20...+50)°C
IP20
M
1 2
A
B
C
3
4
Utility Model - IB2232001 - 06/19 - Finder S.p.A. con unico socio - 10040 ALMESE (TO) - ITALY
22.32 MODULAR CONTACTORS 25 A
Contact gap ≥ 3 mm for NO contacts only; NC contacts ≥ 1.5 mm.
Compliant with EN 61095: 2009.
AC/DC silent coil (with varistor protection).
CONNECTION DIAGRAM
OUTLINE DRAWINGS
FRONT VIEW
A = Selector (22.32.0.xxx.xx40)
The three-position manual selector has the following functions:
ON position
The contacts are latched in the operated state (NO contacts -
closed and NC contacts - open), the mechanical indicator is visible
in its window, the LED is not illuminated.
AUTO position
The state of contacts, mechanical indicator and LED follow the coil
supply voltage.
OFF position
Even if terminals A1 - A2 are supplied with rated voltage, the coil
is not energized, and so the contacts remain in the non-operated
state, the mechanical indicator is not visible and the LED is not
illuminated.
B = LED
C = Mechanical indicator
ACCESSORIES
- Auxiliary contact module available, “Quick assembly” with the main
contactor 022.33/022.35
- It is not possible to assembly the auxiliary module on 22.32.0.xxx.x4x0
(2 NC versions)
OTHER DATA
It is suggested an air gap of 9 mm between adjacent relays for installations
and working conditions close to the limit (that is, ambient temperature
> 40°C, coil operated for a prolonged period of time, all contacts loaded
with current > 20 A).
1
2
3
4
ENGLISH


Produktspezifikationen

Marke: Finder
Kategorie: Nicht kategorisiert
Modell: 22.34.0.024.4720

Brauchst du Hilfe?

Wenn Sie Hilfe mit Finder 22.34.0.024.4720 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Finder

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-