Fetco HWD-2110 TOD Bedienungsanleitung

Fetco Wasserspender HWD-2110 TOD

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Fetco HWD-2110 TOD (12 Seiten) in der Kategorie Wasserspender. Dieser Bedienungsanleitung war für 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
Temperature On Demand US design patent applied for. Other Temperature On Demand US patents applied for.
FETCO®, is a trademark of Food Equipment Technologies Company.
© 2011 ood E uipment Techno ogies Compa yF q l n Part Number P118 April, 2013
NOTICE TO INSTALLER: Please leave this book with the machine.
®
t∫f Touch Function Selector Technology
HWD-2110 TOD
Four user selectable temperatures - ten gallon/hr
Tem
p
erature on Demand Hot Water Dis
p
enser
2
FETCO® Temperature on Demand
Temperature on Demand
Temperature on Demand
Temperature on Demand Temperature on Demand Hot Water Dispens
Hot Water Dispens
Hot Water Dispens
Hot Water Dispens Hot Water Dispenser
er
er
er er
Contact Information
Contact Information
Contact Information
Contact Information Contact Information
FETCO ®
Food Equipment Technologies Company
600 Rose Road
Lake Zurich • IL USA • • 60047-0429
Internet: www.fetco.com
Phone: (800) 338-2699 (US & Canada)
(847) 719-3000
Fax: (847) 719-3001
Email: sales@fetco.com
techsupport@fetco.com
Description & Features
Description & Features
Description & Features
Description & Features Description & Features
The following variables are adjustable:
Four sele t ble hot t r dispense temper ur s ---W ter tc a wa e at e a emperature se ect ble from 158°F/ 0°C to 20 °F/ °C l a 7 496
English and Metric temperature ranges selectable
Maximum single dispense is 22 ounces/700cc in 15 seconds maximum dispense time
Specifications
Specifications
Specifications
Specifications Specifications
.
Electrical Configurations-DOMESTIC
Configuration
Code
Heater
Configuration Voltage Phase Wires Electrical
Connection KW Maximum
Amp Draw Gallons/Hour
H211010 1 X 5 kW 20 -240 1 2+G NEMA 6-30P pl g 3. -5.1 1 . -21 .3-13. gallon*/3 -51 liter 0 u 6 7 4 956
Electrical Configurations-EXPORT & CANADA
H211020 1 X 5 kW 200-240 1 2+G Cord Only† 3.6-5.1 17.4-21 9.5-13.5gallon*/36-51 liter
* O :N TE Temperature ranges selectable from 158°-20 °F/70-9 °C based4 6 on 207 F/97°C hot water ta k tempe° n rature. † For EXPORT, Cord witho ut plug will be a ached tt
Temperature of dispensed hot water may vary up to 3 ½ % of displayed temperature selection.
*Flow rate per hour based on 65-70°F/18-21°C mains water supply temperature at lowest possible electrical supply current
*Factors affecting temperature accuracy include quantity of hot water dispensed, ambient air temperature, distance of container from hot water faucet (pouring over longer distance causes more cooling)
Power Plug Configurations
Pressure: 40-75 psig, (276-517kPa)
Minimum Flow Rate: 1½gpm (5.7lpm)
Water Requirements:
Water connection inlet: ¼ inch male flare fitting-Cold Water Only
Wei
g
hts and Ca
p
acities
Dispenser Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight
HWD-2110 TOD 24 1/2 in/62 cm 10 in/25.4 cm 19 1/2 in/49.5 cm 4.6 gallon/17.4 liter 30 lbs/13.6 kg 68.3 lbs/31 kg 44 lbs/20 kg
NEW TECHNOLOGICAL FEATURES
The FETCO hot water dispenser uses new t
t
t
tt∫
∫
∫
∫∫f
f
f
f f Touch Function Selector Technology to operate the hot water dispenser.
The t
t
t
tt∫
∫
∫
∫∫f
f
f
f f Touch Function Selector buttons (above and below display screen) alternately dim and brighten when selection is not active.
Dispensing and Feature Selections activate when touched. The front panel is clean and uncluttered.
The display screen shows four temperature selections and the readiness status of each level.
Programming, display and error codes are interactive and more intuitive.
Float indicator is built into drip tray to help simplify maintenance and cleaning.
NEMA PLUG CONFIGURATION
NEMA 6-30P
3
Dimensions & Utility Connections
Water inlet fitting: ¼ inch male flare fitting
Installation
Installation
Installation
Installation Installation
The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Utilize only
qualified beverage equipment service technicians for installation.
A Service Company Directory may be found on our website, http://www.fetco.com.
Setup
1. Before placing the unit, verify that it will fit in the space intended for it, and that
the counter or table will support the weight of the HWD-2110 when filled.
2. When the unit is in position, use a bubble level to level it front to back and side
to side by adjusting the legs.
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. Install a shut off valve near the unit to facilitate service.
3. Install a backflow prevention device, a spring loaded double check valve such as a
WATTS® SD-2 or SD-3, two models accepted by most zoning authorities.
The check valve should be as close to the water supply inlet as possible.
4. An inline water filter is highly recommended. It should be installed after the water
shutoff valve and in a position to facilitate filter replacement.
5. Flush the water supply line and filter before connecting it to the unit.
6. Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water
pr sure is etwe n 40-75 psig ( 7 -5 7kP . es b e 2 6 1 a) Use cold water only.
Electrical Connection
1. Check serial number plate for the maximum wattage and verify that the actual
voltage at the electrical outlet is compatible with the unit’s specifications.
2. Plug unit in. Note that the plug is NEMA 6-30P, for 30 amp 240 volt supply.
3. The temperature and water tank fill level are pre-set at the factory and there is
no need to turn off the heater during the installation process.
The heating process will start automatically when the tank is filled with enough
water to safely cover the heating element.
WARNING-Do not plug in this equipment or attempt to operate without all covers in place and all screws fastened.
Drawin
g
# 1201.00004.00
Back
p
anel of HWD-2110
Power
Switch
Water
Supply
Inlet
A
ppliance Inlet
(attach power cord)
Tank
Drain
Tank
Vent
Warning: Legs are to be adjusted
only to level the unit. Do not extend
them higher than necessary
!
Warning:
To prevent electrical shock, this
unit must be properly grounded.
!


Produktspezifikationen

Marke: Fetco
Kategorie: Wasserspender
Modell: HWD-2110 TOD

Brauchst du Hilfe?

Wenn Sie Hilfe mit Fetco HWD-2110 TOD benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wasserspender Fetco

Bedienungsanleitung Wasserspender

Neueste Bedienungsanleitung für -Kategorien-