RUNNING ORDER:
http://airways.endorphin.es
ENDORPHIN.ES® – RUNNING ORDER
Module design by Andreas Zhukovsky
Collection Spring/Summer 2021
Endorphin.es are made in Barcelona, Spain
Follow, like, post and tag us at instagram:
@endorphin.es
WARRANTY
RTFM – be so kind and read the manual. It will provide you with the information you need to fully indulge the module you justpurchased – for which we like to thank you.
Enjoy your sound experiences, dear sonic traveller. Beginning from the product's purchase date a 1-year warranty is guaranteed for each product in case of any manufacturing errors
or other functional deficiencies during runtime.
The warranty does not apply in case of:
• damage caused by misuse • mechanical damage arising from careless treatment (dropping, vigorous shaking, mishandling, etc.)
• damage caused by liquids or powders penetrating the device • heat damage caused by overexposure to sunlight or heating • electric damage caused by improper connecting
The warranty covers replacement or repair, as decided by us. Please contact us via email for a return authorization before sending anything. Shipping costs of sending a module back for
servicing is paid by the customer. Device complies with all EU regulations concerning RoHS lead-free manufacturing and WEEE disposal
Visit us:
http://endorphin.es
https://youtube.com/user/TheEndorphines
https://facebook.com/TheEndorphines
https://www.instagram.com/endorphin.es/
For technical requests: support@endorphin.es
For general requests: info@endorphin.es
FURTH BARCELONA, S.L.
VAT ID: ES B66836487
FIRMWARE UPDATE
Repeats I/II :
manual knobs
with CV inputs.
Set amount of active
trigger repeats or
Euclidean trigger fills
LISTEN TO THE HEART BEAT CAREFULLY
• 6 HP wide, 2-track trigger generator
• Zero-jitter clock generation: less than 50 microseconds internal clock jitter
• 101-style 16th note input mode (step/rest) with manual or CV controllable
amount of trigger repeats after the active trigger step happens.
• Euclidean mode enabled for each track, set total length and the number of fills
inside the Euclidean circle. Fill amount is also CV controllable.
• Individual reset inputs per track, reset for track 1 is normalled to reset of track 2
• Clock divider for incoming external clock allows to quickly obtain various
musical divisions on the fly incl. triplets of course, but more importantly tuplet
mode lets you stretch the desired amount of trigger repeats into a single bar.
• Dedicated mute buttons for each track
• 8 patterns of trigger sequences stored in the module and will be recalled on
each power cycle.
Depth: 30 mm (with plugged in ribbon cable)
Power requirements: +12V: 30 mA, -12V: 10 mA
red/brown pair of wires correspond
to negative -12V power connector
connect to the
power bus board
POWER CONNECTION
back side of the module
connect to the module
from the back side
-12V / red stripe
polarity marking
- If in live mode, the buttons
are individual Track I and II
MUTE buttons.
- If in step record mode,
the buttons are used for
adding steps and rests.
- If in Euclidean record mode,
the buttons set the length
of the Euclidean circle
(+1 step pressing STEP and
+16 steps by pressing REST)
Rate/divider knob:
- if no clock cable is inserted, then
this knob sets the speed of the internal
clock in BPM, from 30 to 300;
- if clock is inserted via cable, this knob
sets the speed of dividers/tuplets for
the repeats.
© Endorphin.es® 2011–2021
When a CV cable is inserted,
each Repeats knob acts as CV
attenuator; expected CV range: 0...+5V
power OFF you modular system:
hold STEP while powering your system again:
you will see the illuminati LED
slowly blink :BLUE
WAV
with simple mono or stereo cable connect
audio output from your computer headphones
output to REPEAT 1 CV IN input of the module
Press PLAY and wait 2+ minutes.
Illuminati LED will quickly blink .BLUE
The modue will reboot automatically blinking
FUCHSIA LED after new firmware is installed
Disable alarms and notifications during
the update process as they will most likely
interupt the update procedure, flight mode
on phones is recommended.
When Illuminati LED flashes RED
that means signal is too low or too high:
Just reset the firmware update process by
pressing once and regulating the signal levelREST
with RATE knob: full CCW: 1x amplification,
full CW: 10x amplification).
Video update guide: https://youtu.be/WKt7FdRGRYI
External clock
input, 16th
notes clock
expected (PPQN26)
(0...+5V or +10V,
0.65V threshold)
Reset/syncronization trigger inputs.
Each trigger applied resets a certain track’s
sequence to its first step.
‘Reset in I’ is normalled to ‘reset in II’, if no
cable is inserted into ‘reset in II’.
Track selector switch:
- record a trigger sequence or set
the Euclidean length by switching
to the left (track I) or right (track II);
- playback live mode in the middle
Output Output Output
track I and II trigger outputs,
trigger output length: 10 msec
Output range: 0...+10V
LED indicator:
- blinking to BPM in blue in live mode;
- lights up red in step recording,
- fuchsia in euclidean recording
Clock output:
- internal clock out jack: 30...300 BPM in 16th notes
(PPQN24÷6) when no external clock applied;
- external clock output in 16th notes after divider;
Output range 0...+10V
Output Output
results in
5-step long
infinitely repeating
trigger sequence:
OPERATING MODES
1.1 Recording the trigger sequence in step mode:
LED light up in standard step recording modeRED
if track selector is switched to the right or to the left
1.0 Step a.k.a. 'standard' mode
2.0 Euclidean mode
Record a trigger sequence to track I or II
using STEP and REST buttons Switching the
track select to the
middle
first step of recorded
5-steps sequence ...
last step of
recorded sequence
buttons pressed 5 times in total
the recorded sequence willre triggers
on 1st, 2nd and 4th step
repeating the
same sequence
again repeating the same
sequence of triggers
and so on
x1 x1 x1 x1 x1
1.2 Repeats in step mode
x1 x2 ...
Record a simple 3 step trigger sequence
1 2 3 4 5
1 2 3
with REPEATS I knob set to 0:
Adjusting REPEATS amount will add 0-7 trigger repeats after an active step in the sequence, thus increasing the total sequence length:
1 2 3 4
...
1
0
original first trigger
repeated trigger empty steps (rests) of the sequence
repeated same sequence
...
2
original first trigger
x2 times repeated trigger empty steps (rests) of the sequence
repeated same sequence
again same
repeating sequence, etc.
1 2 3 4 5
With CV applied we can
dynamially change
amount of repeats
2 sec 2 sec
Holding STEP (for track 1) or REST (for track 2) button for 2 seconds will enable (or disable) Euclidean mode:
2.1. Recording the sequence length in Euclidean mode:
Switch to the left to check if track I is in Euclidean mode or switch to the right to check if track II is in Euclidean mode.
LED lighs up
FUCHSIA
LED lighs up
FUCHSIA
x1
x1
each single press adds
+1 step to the Euclidean circle
each single press adds
+16 steps to the Euclidean circle
switching to the center,
saves the steps amount
step 1
step 2
step 3
step 4
step 5
step 6
step 7
step 8
step 9
step 10
step 11
step 12
step 13
step 14
step 15
step 16 Euclidean circle with default
count of 16 steps
with REPEATS knob we set
the number of fills (active
steps equally distanced
within the euclidean circle)
With CV applied we can
dynamially change
the amount of fills
0
no
triggers 1
1
trigger
22
triggers
3
3
triggers
4
4
triggers etc.
...
3. Live mode
Short press on STEP or REST
buttons will mute/unmute trigger
outputs on either Track I or II
In live mode both tracks
infinitely repeat their
trigger sequences. 4. Clock divider
With external clock applied, the
divider is set with rate/div knob
to be applied to trigger repeats
or Euclidean circle speed;
middle knob position (x1)
doesn't affect the clock divider.
6. Syncronization
In TUPLET mode (div knob fully CCW)
the number of trigger
repeats is streched into one bar.
Some particular cases of using tuplets
are triplets and – if used creatively –
becomes ratcheting.
5.Tuplets
clock output in 16th notes after divider
(PPQN24÷6)
Triggers applied to reset I or II
reset the according trigger sequence to the first step.
Reset in I is normalled to reset in II.
I.e. a reset is applied to both tracks, if a signal
is sent to reset in I only and no cable is plugged
into reset in II.
7. Patterns
Each track has 8 patterns selected by pressing both the STEP and the REST button and rotating the REPEATS (I or II) knob
at the same time. Patterns can be combined and are selected separately for track I and II. Pattern sequences and
last patterns selected are recalled on next power cycle.
Track I or II
pattern 1 pattern 2 pattern 8pattern 7
...
+
pattern 1
pattern 2
pattern 3
pattern 4 pattern 5
pattern 6
pattern 7
pattern 8
separate patten selection
for track I and track II
1 21 2 3 4 5 1 2 3 4 5
1 2 3 1 2 3 1 2
1 2 3 4 1 2 1 2 3 4 5 1 2 3 4 5 1 2
In this mode we set the length of the Euclidean
circle (by default 16 steps) and set the amount
of trigger FILLS with REPEATS knob or its CV.
again same
repeating sequence, etc.
© Endorphin.es® 2011–2021


Produktspezifikationen

Marke: Endorphin.es
Kategorie: Nicht kategorisiert
Modell: Running Order

Brauchst du Hilfe?

Wenn Sie Hilfe mit Endorphin.es Running Order benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Endorphin.es

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-