Owner’s Manual
Plastic Shallow
Jet Pumps
General Safety . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . 3-5
Electrical . . . . . . . . . . . . . . . . . . . . . . . . .6
Operation . . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting . . . . . . . . . . . . . . . . . . . 8
Repair Parts . . . . . . . . . . . . . . . . . . . . . . 9
Jet/Tank Assembly . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . 11
TABLE OF CONTENTS
Safety: Need safety Info
1. Avoid Pressure Burns/Explosion
2. Avoid Electric Shock
Fill Pump with water: Ensure pump body is lled with water to discharge.
Motor’s Electrical Settings: Set motor to proper voltage,
i.e. voltage supplied to pump – See electrical section
Need Help: Call 1-877-326-3561 for assistance
Important Safety Instructions Safety Labels
Carefully read and follow all safety
instructions in this manual and on pump.
SAVE THESE INSTRUCTIONS – This manual
contains important instructions that should be
followed during installation, operation, and main-
tenance of the product. Save this manual for
future reference.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual,
look for one of the following signal words and be
alert to the potential for personal injury!
Indicates a hazard which, if
not avoided, will result in death or serious injury.
Indicates a hazard which,
if not avoided, could result in death or serious
injury.
Indicates a hazard which, if
not avoided, could result in minor or moderate
injury.
NOTICE indicates practices not related to
personal injury.
Keep safety labels in good condition. Replace
missing or damaged safety labels.
General Safety
Risk of burns. Do not
touch an operating motor. Motors are de-
signed to operate at high temperatures. To
avoid burns when servicing pump, allow it to
cool for 20 minutes after shut-down before
handling.
Do not allow pump or any system compo-
nent to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system com-
ponents.
Wear safety glasses at all times when work-
ing on pumps.
Risk of explosion. Pump
body may explode if used as a booster
pump.
GENERAL SAFETY
STOP Before you start
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
2
DEDICATED SHALLOW WELL PUMP INSTALLATIONS
REPLACING AN OLD PUMP
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Disconnect power to pump before
working on pump or motor.
1. Drain and remove the old pump. Check the old pipe for
scale, lime, rust, etc., and replace it if necessary.
2. Install the pump in the system. Make sure that all pipe
joints in the suction pipe are air-tight as well as water
tight. If the suction pipe can suck air, the pump will not
be able to pull water from the well.
3. Adjust the pump mounting height so that the plumbing
connections do not put a strain on the pump body.
Support the pipe so that the pump body does not take
the weight of piping or ttings.
!
(Figure 1)
Foot Valve
Stainer
Well Casing
Sanitary Well Seal
To Power Box
Suction Pipe
Priming Tee with
Priming Port, Plug
and Pressure
Gauge
To House
Water
System
3
Cased Well Installation (Figure 1)
1. Mount the pump as close to the well as possible.
2. Assemble the foot valve, strainer, and well pipe.
Make sure that the foot valve works freely.
3. Lower the pipe into the well until the strainer is ve
feet above the bottom of the well. It should also be at
least 10 feet below the well’s water level.
4. Install a sanitary well seal.
5. Install a priming tee, priming plug, and pressure gauge
to pump’s discharge port. Connect the pipe from the
well to the pump’s suction port, using the fewest
possible ttings-especially elbows – increase friction
in the pipe. The suction pipe should be at least
as large as the suction port on the pump. Support
the pipe so that there are no dips or sags in the pipe,
so not to strain the pump body, and so that it
slopes slightly upward from the well to the pump
(Note: Not doing so can create air locks preventing
the pump from working properly). Seal the suction
pipe joints with PTFE pipe thread sealant tape or a
PTFE-based pipe joint compound. Joints must be air-
and-water-tight. If the suction pipe can suck air,
the pump cannot pull water from well.
6. See instructions on page 8 for connecting discharge
pipe to tank.
Produktspezifikationen
Marke: | Eco-Flo |
Kategorie: | pomp |
Modell: | Plastic Shallow Jet Pump |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Eco-Flo Plastic Shallow Jet Pump benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Eco-Flo
31 August 2024
22 August 2024
22 August 2024
22 August 2024
22 August 2024
22 August 2024
22 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024