Dri Eaz DriForce Bedienungsanleitung

Dri Eaz Heizung DriForce

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Dri Eaz DriForce (14 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/14
07 00274- L F211, F211-AK, F211- 1 Legend Brands, Inc. BU
Owner’s Manual
DriForce™ InterAir Drying System
Models , F211-AK, F211- F211 BU
Legend Brands, Inc.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800- -3030 Fax: 360- -7950 932 757 LegendBrandsRestoration.com
The DriForce InterAir Drying System allows the restorer to direct high-pressure air into wet walls,
behind cabinets, and into other hard- -reach structures with minimal disruption to materials. to
Provides fast, eective drying in all types of assemblies and materials.
Patents: www.LBpatents.com
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING! To reduce the risk of re or electric shock, do
not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an ex-
tension cord. Connect only to an outlet provided with a
ground fault interrupting device.
WARNING! Do not touch grills when unit is operating.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving unit.
WARNING: Do not allow children to play with or around the
unit. Be sure the unit is inaccessible to children when not
attended.
NOTICE: Always operate the unit on a stable, level surface
so it cannot fall and cause injury.
WARNING! Do not alter or modify your Dri-Eaz product in
any way. Use only replacement parts authorized by Legend
Brands Restoration, Inc. Modications or use of unapproved
parts could create a hazard and will void your warranty. Con-
tact your authorized Dri-Eaz distributor for assistance.
WARNING!
a) Do not operate any fan with a damaged cord or plug. Dis-
card fan or return to an authorized service facility for exami-
nation and/or repair.
Manifolds (×8)
Hose barbs (×5)
Crush-proof
hose (thirteen
7 ft./2 m sec-
tions)
Carry bags (×2)
DriForce muf-
er/lter
DriForce unit
Manifold T-con-
nectors (×2)
ADS tubing
(91 ft.)
Injectors (×100)
Manifold
endcaps (×4)
DRIFORCE AIR DRYING SYSTEM (ADS) COMPONENTS
07 00274- L F211, F211-AK, F211- 2 Legend Brands, Inc. BU
b) Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route cord
under furniture or appliances. Arrange cord away from trac
area and where it will not be tripped over.
WARNING: This product and other substances
that may become airborne from its use contain
chemicals, including lead and phthalates, known to
the State of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to
P65Warnings.ca.gov
BEFORE YOU BEGIN
Warranty registration
Please visit to register your purchase. warranty.drieaz.com
Registration allows us to better assist you with using, main-
taining or servicing your equipment and to contact you in
case we have important safety information concerning your
Dri-Eaz product. If you determine service is required, have
your equipment model, serial number and original proof of
purchase available and call your distributor for assistance
with obtaining a return material authorization (RMA).
OPERATING INSTRUCTIONS
IMPORTANT: Extract standing water before attempting
to dry. Do NOT use the DriForce to extract standing wa-
ter of any kind.
Tools
Pencil, tape measure, razor knife, drywall taping knife,
small pry bar, nail puller, screw driver, a carpet awl, a drill
with a 3⁄16 bit. An electronic stud nder is also useful. in.
Preparing Walls, Cabinets and other As-
semblies for Drying
Walls
Wall drying using an inter-air drying system can be accom-
plished with or without baseboards present. After inspect-
ing walls, insulation, and baseboards, and after evaluating
paint nish considerations, proceed in the manner that de-
livers the most value to the customer.
Remove baseboard or cove base. First, use a razor knife to
score along the top of the base where it meets the wall, to
reduce damage to the painted surfaces and make a profes-
sional re-installation easier. When prying base away from
the wall, protect the wall surface by inserting a drywall
knife between the pry bar and the wall. Pull remaining
nails out of the wall, or through the back of the base-
board. Write a number on the wall and the corre-
sponding base so you will know where to reinstall it.
However, drying success can also be achieved by
making the wall penetrations immediately above the
top of baseboard and proceeding to dry with the base-
boards in place. This a necessary procedure where
there is a desire to save a wall with a tiled wall base,
when value is added by avoiding the detachment of
wall baseboards.
Making air access holes
Punch holes with a carpet awl use a drill with a or
3⁄16 bit. Create at least one hole between each set in.
of studs and about 2 in. above the oor. An electronic
stud nder can be used to locate studs and nd the
center of the cavity .
Larger holes are more time-consuming to patch, and may
decrease eciency by leaking air. Try to reduce the need
for later repairs by placing the holes behind the rubber
wainscoting or cove base, or behind trim that is easily rein-
stalled over the holes.
Steel Studs
Steel studs are common in commercial buildings. They are
set in a channel that can hold large volumes of water. To
access these areas, drill holes approximately ½ inch from
The DriForce and the Air Drying System can deliver air to struc-
tural cavities in walls, ceilings, under and above cabinets, and
many other areas.
The ADS connects to the DriForce blower outlet and attaches
to a manifold with a standard hose cu. Supply tubes run from
the manifold to injectors that are inserted into a wall or other
structural cavity.
ON/OFF
switch in
base (not
shown)
DRIFORCE BLOWER
Vacuum IN
Blower OUT
Wrap cord
around unit
when not in
use.
07 00274- L F211, F211-AK, F211- 3 Legend Brands, Inc. BU
the oor at a downward angle. Take care, however, not to
immerse the ends of the tubes in any standing water that
may be present.
Ceilings and Cabinets
The larger lumber sizes and structural cavities in ceilings
will require more air airow to dry properly.
Moisture under and behind cabinets may be dicult to de-
tect, but it is safest to assume that moisture is present if
water has owed through these assemblies. Make sure to
provide as much airow as possible. you cannot properly If
access all interior spaces the cabinets may need to be re-,
moved.
NOTICE: Do not use the DriForce to extract liquid water or
debris of any kind. This may damage the unit and void the
warranty.
DriForce Blower Setup
The DriForce Blower is equipped with a blower outlet, a
vacuum inlet, a power switch and a power cord. Plug in unit
to an appropriate grounded 115V outlet rated for 15 amps.
Attach vacuum hoses to the vacuum inlet and/or blower
outlet.
Set the DriForce blower out of trac areas to minimize high
a trip- -fall hazard from the blower and the ADS. and
NOTE: The muer/lter supplied with the DriForce should
only be installed when using the DriForce in the Air Injec-
tion (Blower) mode, described under Phase 2 below. Do
not use the muer-lter when using with the DriForce in
the air extraction mode (Phase 1) e lter is not intended . Th
to be used on the inlet (vacuum) side of the DriForce.
Switch power on and o with the toggle switch, found in the
base of the unit.
Air Drying System (ADS) Setup
Manifold conguration
Next, determine the number of manifolds needed for the
job. The following setup will deliver 25 to 30 air exchanges
per hour in each cavity, which is eective for most situa-
tions. Use a formula of one manifold (each manifold has 12
injectors) for each 14 feet of interior 2 × 4 framed wall. For
2 × 6 exterior framed walls, common walls in apartments
and condos, double-sheeted re walls, and dense or water-
resistant covered walls, use a formula of one manifold (12
injectors) for each 7 feet of wall.
After determining the number and length hose assem-of
blies and manifolds, set up the ADS system. Pre-assem-
bling the manifolds, tubing and injectors will save consider-
able time.
Supply t congurationube
Two 200 ft. ( m) lengths in. (0.375 mm) ID air supply 60 of ⅜
tubing are provided. This tubing can be cut to length with a
pair of sturdy scissors or a utility knife. We recommend the
cutting following tubing lengths to create a setup suitable
for most standard wall-drying jobs:
1. Set up THREE manifolds with the following lengths
of tubing:
Manifold
no.
Tubing
quantity
Tubing
length
Tubing locations
on manifold outlets
1
4
4 ft.
1.2 m
Outlets 1, 2, 11
and 12
2
4
3 ½ ft.
1 m
Outlets 3, 4, 9 and 10
3
4
1 ft.
30 cm
Outlets 5, 6, 7 and 8
2. Set up the remaining FIVE manifolds with the follow-
ing lengths of tubing:
Manifold
no.
Tubing
quantity
Tubing
Length
Tubing locations
on manifold outlets
4
2
7 ½ ft.
2.3 m
Outlets 1 and 12
5
2
6 ½ ft.
2.0 m
Outlets 2 and 11
6
2
5 ½ ft.
1.7 m
Outlets 3 and 10
7
2
4 ½ ft.
1.4 m
Outlets 4 and 9
8
2
2 ½ ft.
0.8 m
Outlets 5 and 8
9
2
1 ft.
30 cm
Outlets 6 and 7
To install the tubing, slide the one end of the tubing over
the manifold outlet nipple and insert injector in the other an
end.
Tightly seal o the last manifold on each run of ADS with
an end-cap plug. Now place the injectors into the holes you
have drilled or punched in the wall, cabinet or other assem-
bly.
Diagram shows two inline ADS lines (left), and two double-ADS
lines running from a T-tting. It also shows tubing layouts for
one or two injectors into each wall cavity.


Produktspezifikationen

Marke: Dri Eaz
Kategorie: Heizung
Modell: DriForce

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dri Eaz DriForce benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Dri Eaz

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung fĂźr -Kategorien-