Drayton Digistat+1 Bedienungsanleitung
Drayton
Thermostate
Digistat+1
Lesen Sie kostenlos die đ deutsche Bedienungsanleitung fĂŒr Drayton Digistat+1 (4 Seiten) in der Kategorie Thermostate. Dieser Bedienungsanleitung war fĂŒr 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/4
N L 1 2 3 4
50 mm
minimum
clearance
40 mm
minimum
clearance
40 mm
minimum
clearance
70 mm
minimum
clearance
N L 1 2 3
230V a.c.
Fused 3A
Common
Heating
satisfied
or call for
cooling
Call for
heat
Volt free contacts
Digistat+1 & Digistat+1RF
Room Thermostat
Models:
RF710/22190/22192
Invensys Controls Europe
Technical Helpline: +44 (0) 845 130 7722
www.draytoncontrols.co.uk
User Guide
What is a room thermostat?
... An explanation for householders
A room thermostat simply switches the heating system on
and off as necessary. It works by sensing the air temperature,
switching on the heating when the air temperature falls below
the thermostat setting, and switching it off once this set
temperature has been reached.
Turning a room thermostat to a higher setting will not make
the room heat up any faster. How quickly the room heats up
depends on the design of the heating system, for example, the
size of boiler and radiators.
Neither does the setting affect how quickly the room cools
down. Turning a room thermostat to a lower setting will result
in the room being controlled at a lower temperature, and saves
energy.
The heating system will not work if a time switch or programmer
has switched it off.
The way to set and use your room thermostat is to ïŹnd the
lowest temperature setting that you are comfortable with,
and then leave it alone to do its job. The best way to do this
is to set the room thermostat to a low temperature â say 18ÂșC
â and then turn it up by one degree each day until you are
comfortable with the temperature. You wonât have to adjust the
thermostat further. Any adjustment above this setting will waste
energy and cost you more money.
If your heating system is a boiler with radiators, there will
usually be only one room thermostat to control the whole
house. But you can have different temperatures in individual
rooms by installing thermostatic radiator valves (TRVs) on
individual radiators. If you donât have TRVs, you should choose
a temperature that is reasonable for the whole house. If you do
have TRVs, you can choose a slightly higher setting to make sure
that even the coldest room is comfortable, then prevent any
overheating in other rooms by adjusting the TRVs.
Room thermostats need a free ïŹow of air to sense the
temperature, so they must not be covered by curtains or
blocked by furniture. Nearby electric ïŹres, televisions, wall or
table lamps may prevent the thermostat from working properly.
Controls and Display Layout
* Temperature displayed while adjusting the settings. Once adjustment is
complete and after 5 seconds this will disappear. When the OFF button is
pushed the word âOFFâ is displayed here.
** When the OFF button is pushed the OFF temperature is displayed here.
Simple Setting or Operating
To set the required room temperature
î âąîTheîdisplayînormallyîshowsîtheîcurrentîroomîî î
î î temperatureîtoîwithinî0.5ÂșCî
î âąîîToîadjustîtheîrequiredîtemperature,îpressîthe
î î â+âîbuttonîtoîincreaseîtheîtemperatureîsetpoint
î î orîtheîâ-âîbuttonîtoîreduceîtheîtemperatureî
î î setpoint.îTheîLCDîwillîdisplayîtheîtemperatureî
î î setpointîasîitîisîbeingîadjustedîinîtheîbottomî
leftîofîtheîdisplay.
âąîAfterîaîfewîsecondsîtheîdisplayîwillîreturnî
to
î î normalîoperationîandîwillîdisplayîtheîactualîî î
î î roomîîtemperatureî&îtheîSunîsymbol.
Whileîadjustingîtheîtemperatureîduringînormalîîîî
îoperation,îwhenîyouîreachîtheîmaximumîorîî
îminimumîpossibleîsettingîtheîsetpointîwillîîashîtoî
îindicateîyouîcannotîadjustîtheîproductîfurther.
To turn the Thermostat Off
âąîPressîtheîâOFFâîbuttonîandîtheîdisplayîwillîbeîasîshown
âąîIfîtheîroomîtemperatureîfallsîbelowîtheîoffîsetpoint
î î temperature,îtheîproductîwillîcontrolîatîtheîOFFîî î
î î temperature.
06515065001 ISS B
Tear hereTear here
Digistat+1 & Digistat+1RF
Room Thermostat
Models:
RF710/22190/22192
Invensys Controls Europe
Technical Helpline: +44 (0) 845 130 7722
www.draytoncontrols.co.uk
InstallationîGuide
RFîPRODUCTîONLY
INSTALLATIONîOFîSCRî(RFîModelsîonly)
If you do not have the knowledge to install the SCR safely then you
must arrange for a competent electrician to install it for you. Wiring
must conform to the current IEE wiring regulations.
Prior to commencing the installation you must ensure the mains
supply is switched off.
InstallationîInstructions
Readîallîinstallationîandîcommissioningîinstructionsîbeforeî
proceeding.
Doînotîswitchîonîuntilîreadyîtoîcommission.
The system wiring must be able to be fully disconnected from the
mains supply by a switch incorporated in the ïŹxed wiring having a
contact separation of at least 3mm on both poles. Fused at 3A.
Location
The Digistat SCR (receiver) should be mounted in a convenient
position, close to the boiler or central heating system wiring centre.
(Care should be taken not to mount the SCR in a position where it
is surrounded by metal objects or mains voltage cable, as this may
interfere with the radio signal).
For the best performance install in an open space, at least 30cm
distance from any metal objects including wall boxes and boiler
housing.
It is recommended that the SCR is mounted on the wall nearest the
ïŹnal location of the Digistat +RF room thermostat and not less than
30cm from the boiler side panel.
Warning:îInstallingîtheîSCRîtooîcloseîtoîtheîmetalîsideîpanelî
orîmainsîcablesîmayîinterfereîwithîtheîradioîsignal.
Combiîboilerîbasicîwiringîlayout
Zoneîcontrolîbasicîwiringîlayout
COMMISSIONINGîTHEîâWIRELESSîSYSTEMâî(RFîModelsîonly)
Standard for all models
IMPORTANT: MULTIZONE INSTALLATIONS ONLY
If more than one âwireless systemâ is ïŹtted within the same property.
ie. for controlling 2 or more zones (multi-zone) it is essential that the
Digistat RF units are matched correctly to the relevant SCR. This is easily
achieved by commissioning each Digistat and SCR in turn.
1. Install (see installation instructions) and turn power on to the
SCR (receiver). If a separate programmer is ïŹtted, ensure that it is
switched on. The red LED should come on.
2. Push the âoverrideâ button on the SCR once. The green LED should
also come on. Check to see if the boiler and/or motorised valve
are working.
3. To enter âlearnâ mode push the button marked 1 followed by 2
(OVERRIDE) and hold both depressed together. The red LED
should ïŹash for 2 seconds and then go out signifying the SCR is in
learn mode. Release both buttons.
4. The red and green LEDâs should both now be on.
5. Take the Digistat RF and hold it within sight of the SCR (no closer
than one metre).
6. Remove the battery cover and ïŹt the batteries.
7. The Digistat RF should now display the actual room temperature.
If the unit has been stored in a cold place, it may take time to warm
up.
8. As soon as the batteries are ïŹtted, the red LED on the SCR should
ïŹash for 7 seconds and then go out.
The green LED may be on or off depending on the room temperature
at the time of commissioning.
9. If the red LED remains on, remove the batteries on the Digistat RF,
check the battery positions are correct, and once the display has
faded, repeat steps 6 to 8.
10. Increase the âSETâ temperature on the Digistat RF by pressing the
+ button until a ïŹame symbol appears, in the left hand segment of
the display.
11. The red LED on the SCR should ïŹash for 7 seconds. This conïŹrms
that the radio signal is being sent and received. After 7 seconds the
red LED should go out and the green one come on.
12. Check to conïŹrm that the boiler and/or motorised valves are
working.
13. Decrease the âSETâ temperature on the Digistat RF by pressing the
- button until the ïŹame symbol disappears.
14. The red LED on the SCR should ïŹash for 7 seconds. After 7 seconds
both the red and green LEDs should go out. Check that the boiler
and/or motorised valve have powered down.
15. Place the Digistat RF in the chosen operating position, (see Digistat
RF location section) and repeat steps 10 to 14. Once you have
conïŹrmed the system operates correctly, ïŹt and secure the Digistat RF
to the wall (see installation instructions).
During normal operation the red LED on the SCR will ïŹash for 7 seconds
each time a radio signal is received from the Digistat RF. This will occur
approximately every 5 minutes.
The green LED on the SCR denotes a call for heat (ON).
Onceîtheîsystemîhasîbeenîsuccessfullyîcommissioned,îbuttonsî1î
andî2îonîtheîSCRîshouldînotîbeîpressedîsimultaneously,îunlessîaî
replacementîDigistatîRFîorîSCRîisîîtted.
Fixingî(minimumîwallîplateîclearancesîshown)
1. Loosen the securing screws, remove the wallplate, and if surface
wiring is to be used, snap out the cable entry strip on the bottom
edge of the wallplate with a pair of pliers.
2. Fix the wallplate, terminals at the top, either direct onto the ïŹat
wall using wall plugs and no 6 x1â wood screws or on a ïŹush
mounting single conduit box using M3.5 x 14 screws. Minimum
wallplate clearances are shown.
3. Complete the wiring to the SCR wallplate in accordance with the
relevant diagram, to comply with current IEE wiring regulations.
4. Place the SCR onto the wallplate and tighten the securing screws.
SCRîwallplateîclearances
Electrical
This product is double insulated and does not require an earth connection.
The SCR should be wired to the combi boiler or central heating wiring using
the correct type of cable or ïŹex. The SCR should be wired in to replace
hard wired room or programmable thermostats shown on the system or
boiler wiring diagrams. Always check other manufacturers instructions for
compatibility.
N L 1 2 3
SCR
L -
N -
Digistat + RF
Radio signals
to SCR - no wiring
Switched
230V a.c.
fused 3A,
Internal
boiler
electronics
External
controls
connections
N L 1 2 3
L
SCR
Switched live
from wiring
centre Motorised valve
N
To boiler
and/or
pump
Radio signals
to SCR - no wiring
230V a.c.
fused 3A
Digistat + RF
BOILER
îî
îî
îî
îî
30cm Min
Preferred side of boiler
The range may be affected by
composition/density and number of walls
between the Digistat +RF and SCR
Radio Signal Range:
30m pically Ty
SCR
06515065001 ISS B
Flame shows when calling for heat
Moon shows when in âOffâ
(setback) mode
Sun shows when in âOnâ (comfort) mode
**Room Temperature
*Setpoint
Temperature
OFF Button ON Button
+ or - buttons
for setting adjustments
To turn the Thermostat On
Youîcanîeither:
î 1.îPressîtheîâONâîbuttonîandîtheîdisplayîwill
î î showîtheîOnîsetpointîandîtheîroomî
î î temperature.
î î AfterîaîfewîsecondsîtheîOnîsetpointîwillî
î î disappearîfromîtheîdisplayîandîtheîproduct
î î willîcontrolîatîtheîOnîsetpointîtemperature.
î 2.îPressîtheîâ+âîorîâ-âîbuttonîandîtheîdisplayîwill
î î showîtheîOffîsetpointîandîtheîroomî
î î temperature.
î î Nowîpressîtheîâ+âîorîâ-âîbuttonsîuntilîtheî î
î î requiredîsetpointîtemperatureîisîshown.
î î Afterîaîfewîsecondsîtheîsetpointîwillî
î î disappearîfromîtheîdisplayîandîtheîproduct
î î willîcontrolîatîtheînewîtemperature.
Note:îTheîDigistat+1îRoomîThermostatîwillî
î î onlyîcontrolîtheîheatingîwhenîtheîTimeswitch
î î orîProgramerîisîinîaîtimedîOnîperiod.
On
Receive / Alarm
Override 2
1
Learn
Mode
Digistat SCR
Wireless System
FEATURES
Thisîproductîhasîtheîfollowingîuserîadjustableîsettings
î âąîRequiredîroomîtemperatureî(temperatureîsetpoint)î
î âąîOffîtemperatureîsetting
î âąîOnîtemperatureîsetting
î âąîMinimumî&îMaximumîtemperatureîsettings
ADVANCEDîFEATURES
AdjustingîtheîSetpointîusingîtheîOnîandîOffîbuttons
The âOffâ button can also be used to adjust the temperature setting
to a setback level and the âOnâ button can also be used to adjust the
temperature to a comfort level.
The setback feature is designed for those interested in saving energy
and have a varied lifestyle. It means that when leaving the house for
a shopping trip or a night out, the user can adjust the temperature
to a lower level by pressing the âOffâ button, with the comfort level
restored on their return by pushing the âOn âbutton.
NB. This feature can be used to quickly adjust the temperature
setpoint to a setback temperature for economy operation if for
example, âOffâ Temperature = 15ÂșC and the On temperature can
be used to quickly adjust the temperature setpoint to a comfort
temperature if for example âOnâ Temperature = 22ÂșC.
Toîchangeîtheîuserîadjustableîsettingsî
A range of user settings can be adjusted,
1. Maximum Temperature
2. Minimum Temperature
3. Off Temperature
4. On Temperature
î âąîToîenterîtheîâUserâîmenu,îpressîandîholdîtheîâOnî&îOffâîbuttonîî
for more than 5 seconds â the display will show âHiâ and the
maximum setpoint.
î âąî
If the âOnâ button is pressed the display will show âLoâ and the
minimum setpoint.
î âąî
If the âOnâ button is pressed again the display will show âOFFâ and the
OFF setpoint.
î âąî
If the âOnâ button is pressed again the display will show Onâ and the
On setpoint.
ChangingîtheîMaximumîTemperatureîSetting
î âąîToîadjustîtheîmaximumîtemperatureîenterîtheîuserîmenuîasîî
described previously, then press the âOnâ button until âHiâ is shown.
î âąîPressîtheîâ+âîbuttonîtoîincreaseîtheîmaximumîtemperatureî
setting (max. 30oC) and the â-â button to reduce the maximum
temperature setting (min. 5oC or min temp setting).
Changing the Minimum Temperature Setting
î âąîToîadjustîtheîminimumîtemperatureîenterîtheîuserîmenuîasîî
described previously, then press the âOnâ button until âLoâ is shown.
î âąîPressîtheîâ+âîbuttonîtoîincreaseîtheîminimumîtemperatureîsettingîî
(max. 30oC or max. temp. setting) and the â-â button to reduce the
minimum temperature setting (min. 5oC).
Location
Room Thermostat
1.5m
Care should be taken to mount the thermostat in a position which is not
subject to direct sunlight or draughts. Preferably it should be mounted
on an inside wall about 1.5m (5ft) above the ïŹoor in a position where it
can respond to room temperature but away from the direct inïŹuence of
radiators or other appliances giving off heat.
SignalîStrengthî(RFîModels)
Before ïŹxing the to the wall it is recommended to ïŹrst check Digistat+RF
the signal strength from that location.
To do this, remove the batteries, press and hold the â+â button whilst
reïŹtting the batteries, the display will show ârFâ which indicates that the
Digistat+RF is continuously sending an OFF signal to the SCR (receiver).
Leave the in position and return to view the SCR. If the red Digistat+RF
LED is continuously ïŹashing, this indicates a good signal. If the red LED is
not ïŹashing, this indicates a poor signal and you need to reposition the
Digistat+RF until the red LED is ïŹashing.
When the signal strength has been conïŹrmed remove the batteries to
cancel the test and follow the installation instructions.
BeforeîInstallation
If you do not have the knowledge to install the thermostat safely then
you must arrange for a competent electrician to install it for you. Wiring
must conform to the current IEE regulations.
Prior to commencing the installation you must ensure the mains supply is
switched off.
1. Remove the front cover using a ïŹat screwdriver and separate from
back plate (Fig 1).
2. Fix the back plate directly onto the wall using suitable wall plugs and
screws or mount over existing wall box (Fig 2).
(Fig 1)
(Fig 2)
(Fig 3)
FAULTîDIAGNOSISî(AllîModels)
IfîtheîdisplayîshowsîE1,îtheîfollowingîfaultsîcouldîhaveîoccurred
1. Internal temperature sensor has failed.
2. Ambient temperature is outside product operating temperature range.
INSTALLERîOPTIONS
The following installer options can be adjusted,
1. Application Type
2. System Capability
âąîToîenterîtheîâInstallerâîmenu,îpressîandîholdîtheîâOffî&î+âîbuttonsîforîmoreî
than 5 seconds â the display will show âInstâ (Installer menu) as shown,
ApplicationîType
âąîPressîtheîâOnâîbuttonîuntilîâAp:tyâî(ApplicationîType)îisîshown,îwithîtheîcurrentî
setting.
âąîPressîîtheî+îorîâîbuttonsîtoîselectîbetween,
9 = Gas Boiler
0 = Oil Boiler
E = Electric Heat (Relay model only)
Once a value has been changed, pressing âOnâ before exiting the menu
will save the new setting.
System Capability
Adjust this setting to suit the heating system capability.
âąîPressîtheîâOnâîbuttonîuntilîâSystâî(SystemîCapability)îisîshown,îwithîtheî
current setting.
âąîPressîîtheî+îorîâîbuttonsîtoîselectîbetween,
F = Fast â the house usually reaches setpoint in < 1 hour
S = Slow â the house usually reaches setpoint in > 1 hour
Once a value has been changed, pressing âOnâ before exiting the menu
will save the new setting.
To return to normal operation, either press and and hold the âOff & +â
buttons for more than 5 seconds or wait for 1 minute and it will return
automatically.
3. Replace the front cover by locating in position and pushing fully onto
the back cover (Fig 3).
Drayton
4. Remove the battery cover using a coin (Fig 4).
5. Install the 2 AA batteries provided (Fig 5).
6. Replace battery cover (ïŹg 6).
7. The Digistat +1RF is now installed and will automatically start to control the
room temperature.
WIRINGî(NotîRFîModels)
Drayton
Dray ton
Dray ton
Dray ton
(Fig 4)
(Fig 6)
(Fig 5)
Changing the Off Temperature
î âąîToîadjustîtheîâOffâîtemperatureîenterîtheîuserîmenuîasîdescribedîî î
previously, then press the âOnâ button until âOffâ is shown.
î âąîPressîtheîâ+âîbuttonîtoîincreaseîtheîOffîtemperatureî(max.î16ÂșC or max.
temp. setting) and the â-â button to reduce the Off temperature (min. 5ÂșC
or min. temp. setting).
Changing the On Temperature
î âąîToîadjustîtheîâOnâîtemperatureîenterîtheîuserîmenuîasîdescribedîî î
previously, then press the âOnâ button until âOnâ is shown.
î âąîPressîtheîâ+âîbuttonîtoîincreaseîtheîOnîtemperatureî(max.î30ÂșC or max.
temp. setting) and the â-â button to reduce the On temperature (min. 5ÂșC
or min. temp. setting).
While adjusting the settings within the menu, when you reach the maximum
or minimum possible setting the display will ïŹash to indicate you cannot
adjust the product further, e.g. you cannot set the on higher than the
maximum temperature setting.
To return to normal operation, either press the âon & offâ buttons for more
than 5 seconds or wait for 1 minute and it will return automatically.
TAMPERîPROOFINGî(AllîModels)
To tamper proof the product i.e. prevent unauthorised adjustment of the
product set the Min and Max temperatures to the same desired value.
FAULTîDIAGNOSISî(AllîModels)
IfîtheîdisplayîshowsîE1,îtheîfollowingîfaultsîcouldîhaveîoccurred
1. Internal temperature sensor has failed.
2. Ambient temperature is outside product operating temperature range.
BATTERYîREPLACEMENTî(Allîmodels)
HowîdoîIîknowîwhenîtoîchangeîtheîbatteries.
When the batteries start to run low a battery icon will ïŹash in the display, to
indicate âlow batteryâ during this time the Digistat +1RF will function normally
(see ïŹg 1).
Please replace batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries.
When the battery icon alone is shown in the display, the batteries are completely
exhausted and the Digistat +1RF will cease to function (see ïŹg 2). Re-activate by
replacing the batteries.
Howîtoîreplaceîtheîbatteriesîseeîfigî3.
Remove the battery cover using a coin. Replace the spent batteries with 2 x
1.5V IEC LR6 (AA) Alkaline batteries ensuring correct orientation. Replace the
battery cover pressing fully home.
Technical Data
DIGISTAT+,îDIGISTAT+RF
ROOMîUNIT
2 x AA Size, 1.5V alkaline batteriesPowerîSupply:
SwitchîTypeî&îRating:
î Relayîversion: SPDT 16(2)A 230V a.c. Volt free
Min.îrecommended
î current: 10mA@24V a.c. (inductive)
Radioîfrequency:
RFîversion: 433 MHz
Radio Signal Range: 30m typically. The range may be affected by
(RFîVersion) the composition / density and number of
walls between the Digistat RF and SCR.
Temperature Range: 5 to 30ÂșC
î ControlîAccuracy:î + 0.5K @ 20ÂșC
AmbientîTemperature: Operating 0ÂșC to 40ÂșC /
Storage â20ÂșC to 55ÂșC
Suitable for surface or conduit box Mounting:
mounting
Wiring:
Relay: Designed for ïŹxed wiring only, to comply
with current IEE wiring regulations (BS7671).
No wiring requiredRF:
BallîPressureîTest: 75ÂșC
PollutionîDegree: 2
DIGISTATî(SCR)
230V a.c.PowerîSupply:
SwitchîTypeî&îRating: SPDT (voltage free) 2(1)A 230V a.c. or
24V a.c./d.c.
Designed for ïŹxed wiring only, to comply Wiring:
with current IEE wiring regulations (BS7671).
îReceptionîFrequency: 433 MHz
RelevantîECîDirectives:îî2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility
Directive
1999/5/EC R&TTE Directive
2006/66/EC Battery Directive
AppliedîStandards: EN60730-1; EN60730-2-9
EN 300 220-2; EN 301 489-3
ElectricîHeat Combi Boiler
BasicîBoilerîwithîZoneîValve BasicîBoiler
RFîPRODUCTîONLY
SCRîRECEIVERî(RFîModelîonly)
SCRî(Receiver)îNormalîOperatingîMode
î âąîOnceîtheîâWirelessîSystemâîhasîbeenîcommissioned,îthereîshouldîbeîîî
little need for any user interaction with the SCR.
î âąîDuringînormalîîoperationîtheîredîandîgreenîLEDsîwillîoccasionallyîbeîî
on, these signify the following;
GreenîLED
The green LED will be on when there is a demand for heating, and off
when there is no demand.
RedîLED
The red LED will ïŹash for 7 seconds, approximately every 5 minutes.
This denotes that a radio signal is being received from the Digistat+RF
unit.
SituationsîRequiringîAttention
RedîLEDîcontinuallyîîashing
î âąîThisîdenotesîthatîtheîbatteriesîinîtheîDigistat+RFîunitîareîapproachingîî
the end of their life (see âbattery replacementâ).
RedîLEDîcontinuallyîon
î âąîThisîdenotesîthatîtheîSCRîhasîbeenîunableîtoîreceiveîaîradioîsignalîî î
from the Digistat+RF unit. This may be caused by the batteries being
dead (see âbattery replacementâ) or some temporary interference with
the radio signal.
î âąîToîresendîandîtestîtheîsignal,îgoîtoîtheîDigistat+1RFîunitîandîremoveîîî
the batteries, after a few seconds (the display will go blank) reïŹt
the batteries and then reset to your desired temperature. If the
radio signal has been successfully transmitted and received, the red
LED will ïŹash for 7 seconds then go off.
î âąîIfîtheîredîLEDîstaysîon,îthereîmayîbeîîsomeîotherîfaultîthatîwillîî î
require the attention of a heating engineer/electrician.
ManualîOveride
î âąîTheîheatingîcanîbeîmanuallyîswitchedîonîandîoffîbyîusingîthe
âOVERRIDEâ button on the SCR in a fault situation, even though
the red LED will stay on until a satisfactory signal is reinstated.
î âąîOnceîîtheîSCRîreceivesîaîsatisfactoryîsignalîagain,îitîwillîî î î
automatically reset itself for normal operation.
ProperîBatteryîRecycling
Electronic devices and batteries, rechargeable or not, should not be
disposed of into ordinary household waste. Instead, they must be
recycled properly to protect the environment and cut down the waste
of precious resources. Your local waste management authority can supply
details concerning the proper disposal of batteries.
In compliance with the EU Directive 2006/66/EC, the button cell battery
located on the printed circuit board inside this product, can be removed
at the end of product life, by professional personnel only.
Drayt on Drayt on
Drayt on
Drayt on
(Fig 3)
(Fig 2)
(Fig 1)
Drayton
Produktspezifikationen
Marke: | Drayton |
Kategorie: | Thermostate |
Modell: | Digistat+1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Drayton Digistat+1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostate Drayton
12 Oktober 2024
10 Oktober 2024
8 Oktober 2024
Bedienungsanleitung Thermostate
- Thermostate AEG
- Thermostate Siemens
- Thermostate EMOS
- Thermostate Vaillant
- Thermostate Honeywell
- Thermostate Zehnder
- Thermostate Theben
- Thermostate Sygonix
- Thermostate Eberle
- Thermostate BTicino
- Thermostate Delta Dore
- Thermostate Fantini Cosmi
- Thermostate GrÀsslin
- Thermostate Oventrop
- Thermostate Salus
- Thermostate Seitron
- Thermostate Emerson
- Thermostate ICY
- Thermostate Plieger
- Thermostate Watts
- Thermostate Horstmann
- Thermostate Heatmiser
- Thermostate White Rodgers
Neueste Bedienungsanleitung fĂŒr -Kategorien-
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
11 Oktober 2024
11 Oktober 2024
11 Oktober 2024