Draper LVC-IV Bedienungsanleitung

Draper Regler LVC-IV

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Draper LVC-IV (4 Seiten) in der Kategorie Regler. Dieser Bedienungsanleitung war für 27 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Draper, Inc. | 411 S. Pearl St. Spiceland, IN 47385
draperinc.com | 765.987.7999 | 800.238.7999
© 2017 All Rights Reserved
|
FORM: LVCIV_110_Wiring17
110-120V LVC-IV Low Voltage Control Module WIRING
INSTRUCTIONS
If you encounter any difficulties installing or servicing
your LVC-IV, call your dealer or contact Draper, Inc.
Figure 1
-Don't let the RF receiver touch metal objects; this could affect the maximum distance the transmitter can be from the RF receiver.
-Disconnect the power supply before installing the RF receiver.
-Avoid electrostatic interference: Static electricity will damage the electronic components.
-Make sure there is more than 5 feet (1.52 meters) between the RF receiver and ground.
-Make sure there is more than 1 foot (30.5cm) between the RF receiver and ceiling.
-Make sure there is more than 1 foot (30.5cm) between the RF receiver and transmitter.
-If using more than one receiver, make sure they are separated by more than 8" (20cm).
Please Note
Technical Specifications:
Power Supply: 110V-120V / 60Hz
Temperature: -40° C – 85° C
Frequency: 433 MHz
Power: <300W
Transmit Power: <10mW
Sensitivity: -110dBm
Fuse: 3.15 Amp
FUSE - 3.15 AMP
250 VAC 5x20mm
Low Voltage
Trigger 4-28 VDC
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Optional
IR Eye
RS232/485
or connection
to next LVC-IV
(universal-either jack)
(supplied by others)
RF Remote
Antenna
WALL SWITCH
AC Power
Input
WARNING
DRY CONTACT
CLOSURE ONLY.
APPLYING VOLTAGE
HERE WILL DAMAGE
CONTROLLER.
To screen/lift.
Seeindividual
productwiring
for details.
To 110V AC-Hot
110-120V LVC-IV Low Voltage Control Module page 2 of 4
InfraRed (IR) Remote Control
1. Plug Optional IR Eye into mini plug input provided on LVC-IV (see Figs. 1 and 3).
2. IR Remote Control transmitter does not need to be "learned" by the LVC-IV. Simply point and operate.
3. Maximum IR Eye cable length is 42" (106 cm).
Please Note: IR Transmitter Range is 26ft. (7.9 metera).
Figure 3
DC Low Voltage Trigger
The LVC-IV comes with built-in connection for sending a DC trigger (4-28 VDC) from the projector to the projection screen.
1. Connect remote trigger voltage from projector to the low voltage trigger cable.
2. Plug the mini-jack plug of the low voltage trigger cable to the LVC-IV (Figure 1 & 4).
3. When projector is the low voltage output of the projector will cause LVC-IV to deploy projection screen. 'ON'
When projector the low voltage is removed from LVC-IV and projection screen will retract into case.'OFF'
Figure 4
Radio Frequency (RF) Remote Control
The LVC-IV comes with built-in Radio Frequency Remote control capability (optional handheld transmitter NOT included).
To "Learn" a remote
1. Press receiver button on LVC-IV (see Fig. 2A).
2. Signal light will flash slowly.
3. Press transmitter's Up button within 10 seconds (see Fig. 2B).
4. Signal light flashes three times quickly.
To "Un-Learn" a remote
1. Press receiver button on LVC-IV (see Fig. 2A).
2. Signal light will flash slowly.
3. Press transmitter's Down button within 10 seconds (see Fig. 2C).
4. Signal light flashes three times quickly.
To "Un-Learn" all remotes
1. Press receiver button on LVC-IV until signal light flashes quickly, then release.
2. Press receiver button once while signal light is flashing.
3. Signal light will stop flashing.
Please Note: Operating range is 250ft (76 meters) open distance. RF Signal will degrade significantly with each wall it is required to penetrate.
If you are experiencing issues with RF signal strength, the RF antenna can be threaded out one of the knockouts for better reception.
Figure 2
Receiv
er
t
CBA
Receiver
Button
Signal
Light
External LVC-IV—Single or Multiple
Projection Screen Wiring Diagram
External LVC-IV—Single or Multiple
Wiring Diagram for and Ambassador Rolleramic
Receiver
Button 3 BUTTON WALL SWITCH
DOWN - BLACK
COM - WHITE
UP - RED
Wall Switch
To 110-120
VAC LINE
RED - to screen (directional)
BROWN - to screen (directional)
YELLOW - to 110V AC-Hot
BLACK - to 110V AC-Hot
WHITE - Common to screen & 110 AC Neutral
GREEN/YELLOW (Ground)
WHITE (Common)
BLACK (Up)
RED (Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
Dashed wiring by electrician
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
RS232/485 Inputs/Outputs
Low Voltage Trigger
4-28 VDC
IR Eye Input
RS232/485 Inputs/Outputs
Receiver
Button
Low Voltage Trigger
4-28 VDC
IR Eye Input
3 BUTTON WALL SWITCH
DOWN - BLACK
COM - WHITE
UP - RED
Wall Switch
To 110-120
VAC LINE
RED - to screen (directional)
BROWN - to screen (directional)
YELLOW - to 110V AC-Hot
BLACK - to 110V AC-Hot
WHITE - Common to screen & 110V AC Neutral
GREEN/YELLOW (Ground)
WHITE (Common)
RED (Up)
BLACK (Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
Dashed wiring by electrician
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
110-120V LVC-IV Low Voltage Control Module page 3 of 4


Produktspezifikationen

Marke: Draper
Kategorie: Regler
Modell: LVC-IV

Brauchst du Hilfe?

Wenn Sie Hilfe mit Draper LVC-IV benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Regler Draper

Bedienungsanleitung Regler

Neueste Bedienungsanleitung für -Kategorien-