Danfoss ECtemp Next Plus Bedienungsanleitung

Danfoss Thermostaat ECtemp Next Plus

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Danfoss ECtemp Next Plus (24 Seiten) in der Kategorie Thermostaat. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
Danfoss ECtemp Next Plus
Electronic Intelligent Timer
Thermostat
Installation Guide
electricheating.danfoss.com
Danfoss ECtemp Next Plus
Installation Guide2
1 Introduction � � � � � � � � � � � � � � � � � � � � � 2
1.1 Technical Specications . . . . . . . . . . . 3
1.2 Safety Instructions. . . . . . . . . . . . . . . 5
2 Mounting Instructions� � � � � � � � � � � � � � � 5
3 Symbols � � � � � � � � � � � � � � � � � � � � � � � � 8
4 Settings � � � � � � � � � � � � � � � � � � � � � � � 10
4.1 Power ON/OFF . . . . . . . . . . . . . . . . 11
4.2 Initial Settings . . . . . . . . . . . . . . . . 11
4.3 Advanced Programmable Timer . . . . . 13
4.4 Temperature Setting . . . . . . . . . . . . 15
4.5 Timer Setting . . . . . . . . . . . . . . . . . 16
4.6 Safety Lock. . . . . . . . . . . . . . . . . . . 17
4.7 Away Mode . . . . . . . . . . . . . . . . . . 17
4.8 Present Floor Temperature. . . . . . . . . 17
4.9 Change to Room control only . . . . . . 18
4.10 Extending Maximum oor temperature
limitation to 45°C . . . . . . . . . . . . . . 18
4.11 Table for 4.9 Change to Room control
only and 4.10 Extending Maximum Floor
temperature limitations to 45°C . . . . . 19
5 Error Codes � � � � � � � � � � � � � � � � � � � � � 20
6 Warranty� � � � � � � � � � � � � � � � � � � � � � � 21
7 Disposal Instruction � � � � � � � � � � � � � � � 21
Table of Contents
Danfoss ECtemp Next Plus
3Installation Guide
1 Introduction
The Danfoss ECtemp Next Plus is an electronic program-
mable timer thermostat used for controlling electrical oor
heating elements. The thermostat is designed for xed
installation only and can be used for both direct heating of
the entire room and for comfort heating of the oor.
More information on this product can also be found at:
electricheating�danfoss�com
1�1 Technical Specications
Operation voltage 85-250V~, 50/60 Hz
Standby power consumption 0,4 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Floor sensor Floor Sensor NTC 10 kΩ
at 25°C
Room Sensor NTC 10 kΩ
at 25°C
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kΩ
18 kΩ
6 kΩ
Control Hysteresis ± 1.0° C