Danfoss ECtemp Next Plus Bedienungsanleitung

Danfoss Thermostat ECtemp Next Plus

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Danfoss ECtemp Next Plus (24 Seiten) in der Kategorie Thermostat. Dieser Bedienungsanleitung war für 20 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
Danfoss ECtemp Next Plus
Electronic Intelligent Timer
Thermostat
Installation Guide
electricheating.danfoss.com
Danfoss ECtemp Next Plus
Installation Guide2
1 Introduction � � � � � � � � � � � � � � � � � � � � � 2
1.1 Technical Specications . . . . . . . . . . . 3
1.2 Safety Instructions. . . . . . . . . . . . . . . 5
2 Mounting Instructions� � � � � � � � � � � � � � � 5
3 Symbols � � � � � � � � � � � � � � � � � � � � � � � � 8
4 Settings � � � � � � � � � � � � � � � � � � � � � � � 10
4.1 Power ON/OFF . . . . . . . . . . . . . . . . 11
4.2 Initial Settings . . . . . . . . . . . . . . . . 11
4.3 Advanced Programmable Timer . . . . . 13
4.4 Temperature Setting . . . . . . . . . . . . 15
4.5 Timer Setting . . . . . . . . . . . . . . . . . 16
4.6 Safety Lock. . . . . . . . . . . . . . . . . . . 17
4.7 Away Mode . . . . . . . . . . . . . . . . . . 17
4.8 Present Floor Temperature. . . . . . . . . 17
4.9 Change to Room control only . . . . . . 18
4.10 Extending Maximum oor temperature
limitation to 45°C . . . . . . . . . . . . . . 18
4.11 Table for 4.9 Change to Room control
only and 4.10 Extending Maximum Floor
temperature limitations to 45°C . . . . . 19
5 Error Codes � � � � � � � � � � � � � � � � � � � � � 20
6 Warranty� � � � � � � � � � � � � � � � � � � � � � � 21
7 Disposal Instruction � � � � � � � � � � � � � � � 21
Table of Contents
Danfoss ECtemp Next Plus
3Installation Guide
1 Introduction
The Danfoss ECtemp Next Plus is an electronic program-
mable timer thermostat used for controlling electrical oor
heating elements. The thermostat is designed for xed
installation only and can be used for both direct heating of
the entire room and for comfort heating of the oor.
More information on this product can also be found at:
electricheating�danfoss�com
1�1 Technical Specications
Operation voltage 85-250V~, 50/60 Hz
Standby power consumption 0,4 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Floor sensor Floor Sensor NTC 10 kΩ
at 25°C
Room Sensor NTC 10 kΩ
at 25°C
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kΩ
18 kΩ
6 kΩ
Control Hysteresis ± 1.0° C


Produktspezifikationen

Marke: Danfoss
Kategorie: Thermostat
Modell: ECtemp Next Plus

Brauchst du Hilfe?

Wenn Sie Hilfe mit Danfoss ECtemp Next Plus benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermostat Danfoss

Bedienungsanleitung Thermostat

Neueste Bedienungsanleitung für -Kategorien-