CyberPower MBP30A5 Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr CyberPower MBP30A5 (14 Seiten) in der Kategorie Anbaustein. Dieser Bedienungsanleitung war fĂĽr 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/14
User’s Manual
MBP15A6
MBP20A6
MBP30A5
CyberPower Systems (USA), Inc.
4241 12th Avenue East Suite 400 Shakopee, MN 55379
Phone: 877-297-6937
Fax: 952-403-0009
www.CPSww.com
K01-0000 1-00 26
Copyright © 2014 CyberPower Systems, Inc.
IMPORTANT SAFETY INSTRUCTIONS
1
This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual
thoroughly before attempting to unpack, install, or operate the Maintenance Bypass PDU (MBP).
CAUTION! The MBP must be connected to a grounded AC power
outlet with fuse or circuit breaker protection. DO NOT plug the MBP into a
an outlet that is not grounded.
CAUTION! The MBP should be placed near the connected equipment
and easily accessible.
CAUTION! To prevent the risk of fire or electric shock, install in a
temperature and humidity controlled indoor area, free of conductive
contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! (No User Serviceable Parts): Risk of electric shock, do
not remove the cover. There are no user serviceable parts inside. Seek
service from qualified service personnel.
CAUTION! To reduce the risk of fire, connect the MBP to a branch
circuit with amperes (MBP15A6) / 20 amperes (MBP20A6) / 30 15
amperes (MBP30A5 maximum over-current protection in accordance )
with the National Electric Code, ANSI/NFPA 70.
CAUTION! The AC outlet, where the MBP is connected, should be
close to the unit and easily accessible.
CAUTION! Only use -marked power cords, (e.g. the power cords on UL
you equipment), to connect the MBP to AC outlet.an
CAUTION! Only use -marked power cords to connect any UL
equipment to the MBP.
CAUTION! Only qualified maintenance personnel should install a MBP.
CAUTION! Do not unplug the unit from AC Power during operation, as
this will remove the ground connection.
CAUTION! To avoid electric shock, turn off and unplug the unit before
installing the input/output power cord with a ground wire. Connect the
ground wire prior to connecting the line wires!
CAUTION! Do not use improper sized power cord as it may cause an
damage to your equipment and cause fire hazards.
CAUTION! Wiring must be done by qualified personnel.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT
EQUIPMENT! Under no circumstances should this unit should be used
for medical applications involving life support equipment and/or patient
care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce
the risk of fire, do not use with or near aquariums. Condensation from the
aquarium can come in contact with metal electrical contacts and cause
the equipment to short out.
CAUTION! The unit has a dangerous amount of voltage. When the
MBP indicators is on, the units may continue to supply power thus the
unit s outlets may have a dangerous amount of voltage even when it s not ’ ’
plugged in to the wall outlet.
CAUTION! Make sure everything is turned off and disconnected
completely before conducting any maintenance, repairs or shipment.
CAUTION! Connect the Protection Earth (PE) safety conductor before
any other cables are connected.
CAUTION! Never install a MBP, or associated wiring or equipment,
during a lightning storm.
CAUTION! Do not work alone under hazardous conditions.
DO NOT INSTALL THE MBP WHERE IT WOULD BE EXPOSED TO
DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR
DRYERS TO MBP OUTPUT SOCKETS!
Copyright © 2014 CyberPower Systems, Inc.
UNPACKING
2
15A / 20A or 30A MBP
(Maintenance Bypass PDU)
User’s manual Registration card
Rackmount brackets (2)
Flat head screws X8L (4) :M4
Pan head screws M5X12L (4) :


Produktspezifikationen

Marke: CyberPower
Kategorie: Anbaustein
Modell: MBP30A5
Gewicht: 2700 g
Produktfarbe: Schwarz
Stecker: NEMA L5-20P
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 0 - 90 %
Zertifizierung: UL60950_1, cUL
Kabellänge: 1.82 m
Gehäusematerial: Stahl
Abmessungen (BxTxH): 431.8 x 76.2 x 50.8 mm
Nachhaltigkeitszertifikate: RoHS
Anzahl der AC-Ausgänge: 5 AC-Ausgänge
AC-Steckertypen: NEMA 5–20R
Stromstärke (maximal): 30 A
Nominale Eingang Spannung: 100 - 120 V
Nominale Ausgang Spannung: 120 V
Rack-Kapazität: 1U

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower MBP30A5 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Anbaustein CyberPower

Bedienungsanleitung Anbaustein

Neueste Bedienungsanleitung fĂĽr -Kategorien-