YOUR ULTIMATE ALLY IN POWER FEATURES SPECIFICATIONS
1. 120V AC outlet Model Number: CPS240PAU
POWERTRIPTM 240
AC MOBILE POWER INVERTER
CPS240PAU
USER MANUAL
2. USB Charging Port
3. LED Indicator Light
Power LED (Green), Input / Output Fault (Red)
4. ON/OFF Switch
5. DC Input Positive Terminal
6. DC Input Negative Terminal
7. Cooling Fan
Input Voltage:
Output Peak Power:
Output Continuous Power:
Output Voltage:
Output USB Voltage:
Output Frequency:
Output Waveform:
Input Fuse (internal):
Input Fuse (cigar plug);
11 to 15 V
240 W
200 W
120 V
5 V
60 Hz
Simulated Sine Wave
25 A
15 A
Protection Features: Overload, Overvoltage,
Overheating, Short-circuit
iWARNING: This product can expose you to chemicals including bisphenol A
(BPA) and styrene (ABS), which is known to the State of California to cause
reproductive harm and cancer. For more information, go to www.P65Warnings.
ca.gov.
IMPORTANT SAFETY WARNINGS
This guide contains important information regarding the safety, operation, maintenance, and storage of this product.
Failure to read this guide and follow the directions could result in injury and/or property damage.
Before installing and using the CyberPower power inverter, please read the manual. Misusing or incorrectly connecting the
Inverter may damage the equipment or create hazardous conditions for users. Read the 8 following safety instructions and
pay special attention to all CAUTION and WARNING statements in the manual.
CAUTION! Do not operate the inverter nearammable CAUTION! Always turn the inverter o when not in use by
materials, fumes, or gases. removing it from the DC accessory port.
CAUTION! Always use the inverter where there is adequate Check the warning labels on battery chargers CAUTION!
ventilation. Do not obstruct the ventilation slots. or adapters before connecting them to the inverter. Do not
connect battery chargers or adapters that have warnings
CAUTION! Never immerse the unit in water or other liquids. about using with inverters.
CAUTION! Proper cooling is essential when operating the
inverter. Refrain from placing the inverter near the vehicle’s
heat vent or in direct sunlight.
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
DC FUSE REPLACEMENT BASIC OPERATION - Loads Under 150W BASIC OPERATION - Loads Over 150W
The CPS480TG2U/B inverter contains protection fuses.
Two on the inverter body and the other on the cigar plug
cable to protect the unit against overloading. If the inverter
draws more than 150 watts via the cigar plug connection,
or more than 480 watts via the battery clamp connection,
the internal fuse may open to protect the inverter, vehicle
battery, and the connected equipment.
To replace the fuse, please followthe instructions below:
1. Turn o the inverter and disconnect any devices from
the inverter.
2. Disconnect the inverter from power source and remove
the leads.
3. Pull the fuse straight out of the holder.
4. Replace with a new 25-amp fuse in the inverter body or a
20-amp fuse located inline on the cigar plug cable.
Spring
Ring
Power plug
15A Fuse
TROUBLESHOOTING
Problem Possible Cause
DC input is below
11 Vdc or over 15 Vdc
Short Circuit
No AC output
Red LED lit
Overload
Inverter hot
Bad connection or
No AC output wiring
Green LED
not lit Fuse is blown
Excessive startup
load. If the start up
Motorized load exceeds the
power tool will inverters peak load
not operate. capability it will
not work.
Contact Pin
Contact Retainer
Solution
Check your battery volts and
recharge or replace the battery.
Disconnect the load.
Reduce the load.
Disconnect the load and operate
the inverter for a few minutes.
Tighten all DC connections
Check fuse and replace or call
service.
Disconnect the load until the
inverter operates normally and
connect the load again.
1. Place the inverter on a
at surface on your
vehicle oor.
2. Make sure the power switch
on the panel is o.
3. Take the power cord
equipped with the cigar
plug and place the ring
terminals over the two
cabling terminals on the
back of the inverter.
4. Place the inverter cigar
plug in the vehicle cigarette
lighter socket.
CAUTION
1. Connect the RED cable to
the POSITIVE terminal of
the inverter.
2. Connect the BLACK cable
to the NEGATIVE terminal
of the inverter.
5. Turn on the power switch. The green light indicates that the
inverter is operating normally and that AC power is available
at the outlet.
6. Verify that the connected device(s) draws less than 150
watts and plug into the AC outlet.
7. Always turn the inverter o when not in use.
CAUTION - Make sure you connect cable red to red and black to black, and make
sure you screw the nuts on tightly.
CAUTION - Use the cigar plug cable only when the vehicles engine is running.
CAUTION - Use the cigar plug cable with the engine o will cause excessive
TM480 User Guide battery drain.
OPERATING AND STORAGE TIPS
The inverter should only be operated under the
following conditions:
Dry - Do not allow water or other liquids to come into
contact with the inverter.
Moderate Temperature - Ambient air temperature should
be between 32 °F - 104 °F (0 °C - 40 °C). Keep the
inverter out of direct sunlight.
Free Air Flow - Keep the inverter’s ventilation slots
unobstructed to ensure air flow to the unit.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
1. Place the inverter on a
flat surface.
2. Make sure the power switch
on the panel is o.
3. Take the power cord equipped
with battery clamps on one end
and place the ring terminals over
the two cabling terminals on the
back of the inverter.
4. Fasten the positive (red)
clamp to the positive battery
post, and thenfasten the negative
(black) clamp to the negative
battery post.
5. Turn on the power switch. The
CAUTION
1. Connect the RED
cable to the POSITIVE
terminal of the battery.
2. Connect the BLACK
cable to the NEGATIVE
terminal of the battery.
green light indicates that the inverter is operating
normally and that AC power is available at the outlet.
6. Take device power cord plug into the inverter
AC outlet.
7. Always turn the inverter o when not in use.
CAUTION - A reverse polarity connection (positive to negative) will blow a fuse
in the inverter and may permanently damage the unit. Damage caused by a
reverse polarity connection is not covered by your warranty.
WARNING - Batteries contain corrosive materials and present an electrical shock
hazard. To prevent irritation and burns, wear protective eyewear and clothing
when you install the inverter or work with the batteries. Take special care to en-
sure that metal tools and personal metal objects like rings and bracelets do not
contact the battery terminals.
Do not place any items on or over the inverter during
operation. The unit will shut down if it overheats.
Proper storage temperature range is
32 °F - 122 °F (0 °C - 50 °C).
Store and use the inverter in a cool and dry environment.
Avoid exposing the inverter to heating elements, direct
sunlight, or high humidity.
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST
© 2023 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
CONFORMANCE APPROVALS equipment generates, uses, and can radiate radio frequency ener- • Reorient or relocate the receiving antenna.
This device complies with Part 15 of the FCC Rules. gy and, if not installed and used in accordance with the instruc- • Increase the separation between the equipment and receiver.
Operation is subject to the following two conditions: tions, may cause harmful interference to radio communications. • Connect the equipment into an outlet on a circuit dierent
(1) this device may not cause harmful interference, and (2) this However, there is no guarantee that interference will not occur from that to which the receiver is connected.
device must accept any interference received, including interfer- in a particular installation. If this equipment does cause harmful • Consult the dealer or an experienced radio/TV technician
ence that may cause undesired operation. interference to radio or television reception, which can be for help.
This equipment has been tested and found to comply with the determined by turning the equipment o and on, the user is
limits for a Class B digital device, pursuant to Part 15 of the FCC encouraged to try to correct the interference by one or more of WARNING: Changes or modifications not expressly approved
Rules. These limits are designed to provide reasonable protection the following measures: by the party responsible for compliance could void the user’s
against harmful interference in a residential installation. This authority to operate the equipment.


Produktspezifikationen

Marke: CyberPower
Kategorie: Akku
Modell: CPS240PAU

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower CPS240PAU benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Akku CyberPower

Bedienungsanleitung Akku

Neueste Bedienungsanleitung für -Kategorien-