140WattACMobile PowerInverter
UserGuide
Figure1.ProductFeature
2004-5-075/front K
Output Power 140 Watts Continuous
Output Voltage 120 Volts +/- 10%
Output Frequency 60 Hz
Output Waveform Simulated Sine Wave
Input Voltage 10.8 to 15.8 volts
Low Voltage Shutdown 10.5 volt
Problem Possible Cause Suggested Solutions
No AC output power
(Power indicator is not
illuminated)
Poor contact with lighter socket
Automotive electrical systems
requires ignition to be on.
Car s lighter soc ket fuse blown
Over-heating
Vehicle s battery below 10.8
volts.
Ensure the inverter adapter is securely
plugged into vehicle s lighter socket.
Replace the lighter socket if necessary.
Turn the vehicle ignition key to the
Accessory position.
Check the vehicle fuse panel and replace
the damaged fuse.
Allow inverter to cool down. Ensure that
there is adequate ventilation around the
unit and load is no more than 140 watts for
continuous operation.
Unplug the inverter and charge the vehicle
battery.
Short/Long Beep Your vehicle s battery input
voltage is below than 10.8 volt.
Vehicle s battery input voltage
is higher than 15.8 volt.
Inverter is overload.
Check vehicle s battery and ensure its
capacity. Change vehicle s battery if
necessary.
Check for your vehicle s battery
manufacturer guideline.
Reduce load to 140 watts max to maintain
regulation.
ContactScrew
Spring
ContactPin
Fuse
DecorativeRing
LighterAdapter
CPS140BI contains a fuse inside in the Lighter Adapter (see Figure 2) to protect the unit against
overloading. If the inverter draws more than 140 watts, the internal fuse may be blownto protect
the inverter, vehicle battery and the connected equipment. To replace the fuse, please follow the
instruction below:
1. Unplug the inverter from the power source.
2. Remove the Contact Screw from the Lighter Adapter.
3. Replace the 15 ampere fuse.
4. Reassemble the fuse, contact pin and contact screw carefully.
5. Ensure all pieces showed in Figure 2 are installed in the sequence shown.
*Note: For in-warranty units, the replacement fuse can be obtained from CyberPower
Technical Support. For out-of-warranty units, the replacement 15 ampere fuse can be obtained
from most electronic supply retailers.
WARRANTY RETURN
C
2004-5-075/ Kback


Produktspezifikationen

Marke: CyberPower
Kategorie: Akku
Modell: CPS140BI

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower CPS140BI benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Akku CyberPower

Bedienungsanleitung Akku

Neueste Bedienungsanleitung für -Kategorien-