Installing
During Operation, when the power switch is on, if power on indicator is not lighted. Please
check the fuse in the converter. If the fuse is damaged; please replace the fuse for the same
value fuse.
Warning signal
Low battery pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Over load pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Caution
• When connected to any appliance, be sure to turn on converter first. And then turn on
the powerswitch of the appliance.
• If the total Watt of electrical appliances exceeds the output capacity of converter, or after
operating for a period of time and the temperature of the converter reaches 60ËšC, the con-
verter shall be reduced AC output by the protection circuit.
• Always place the converter in an environment which is:
- Well ventilated.
- Not exposed to direct sunlight or heat source.
- Out of reach from children.
- Away from water, moisture, oil or grease.
- Away from any flammable substance.
Troubleshooting
If the converter does not appear to be functioning properly, there are several reasons why
the converter may not be responding.
• Poor contact.
- Clean contacts parts thoroughly.
• Receptacle has no power.
- Check fuse, replace damaged fuse.
- Check receptacle wiring. Repair if necessary.
• Overload caused AC output reduce.
- Reduce the wattage of your load to lower than the maximum Watt.
• Thermal caused AC output reduce.
- Under heavy loads for extended periods of time, the AC converter will reduce output
to prevent damage to excess heat. If this happens, please proceed as below:
a) Switch off the powerswitch of the converter.
b) Decrease load of this machine i.e. disconnect some of the appliances or wait until this
converter becomes cool.
c) Switch on the powerswitch off the converter.
• Low-battery shutdown.
- Recharge your battery and resume operation.
GB
C 12100 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 100W
Peak power: 200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 15A x 1pcs
C 12150 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 150W
Peak power: 300W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 20A x 1pcs
C 12300 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 300W
Peak power: 600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 35A x 1pcs
C 12600 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 600W
Peak power: 1200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 3pcs
C 12800 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 800W
Peak power: 1600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 3pcs
C 12400 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 400W
Peak power: 800W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 1pcs
C 121000 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 1000W
Peak power: 2000W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 5pcs
Convertermanual 31-03-2005 08:48 Pagina 5
Produktspezifikationen
Marke: | Caliber |
Kategorie: | Autolautsprecher |
Modell: | C 12300 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Caliber C 12300 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Autolautsprecher Caliber
7 Oktober 2024
9 September 2024
8 September 2024
14 August 2024
1 August 2024
28 Juli 2024
27 Juli 2024
26 Juli 2024
24 Juli 2024
24 Juli 2024
Bedienungsanleitung Autolautsprecher
- Autolautsprecher Clatronic
- Autolautsprecher Exibel
- Autolautsprecher Philips
- Autolautsprecher Sony
- Autolautsprecher MarQuant
- Autolautsprecher Renkforce
- Autolautsprecher Blaupunkt
- Autolautsprecher Kenwood
- Autolautsprecher Autotek
- Autolautsprecher Pyle
- Autolautsprecher Auna
- Autolautsprecher Pioneer
- Autolautsprecher JBL
- Autolautsprecher JVC
- Autolautsprecher Hifonics
- Autolautsprecher Magnat
- Autolautsprecher ICES
- Autolautsprecher Alpine
- Autolautsprecher Renegade
- Autolautsprecher Rockford Fosgate
- Autolautsprecher Crunch
- Autolautsprecher AXTON
- Autolautsprecher Clarion
- Autolautsprecher Mac Audio
- Autolautsprecher ESX
- Autolautsprecher DNT
- Autolautsprecher Boss
- Autolautsprecher Hertz
- Autolautsprecher Kicker
- Autolautsprecher JL Audio
- Autolautsprecher DLS
- Autolautsprecher Dynex
- Autolautsprecher Emphaser
- Autolautsprecher Focal
- Autolautsprecher Fusion
- Autolautsprecher Infinity
- Autolautsprecher Lanzar
- Autolautsprecher Mtx Audio
- Autolautsprecher Radical Audio
- Autolautsprecher Rodek
- Autolautsprecher Soundstream
- Autolautsprecher AudioControl
- Autolautsprecher Metra
- Autolautsprecher Memphis Audio
- Autolautsprecher Aquatic AV
- Autolautsprecher SoundMAX
- Autolautsprecher Sinus Live
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
14 Oktober 2024
14 Oktober 2024
10 Oktober 2024
8 Oktober 2024
7 Oktober 2024
7 Oktober 2024
2 Oktober 2024
2 Oktober 2024
30 September 2024