Blebox gateBox Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Blebox gateBox (4 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂĽr 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Apply the safety systems described in the PN-EN 13241 standard
dening the safety requirements and operational requirements
for gates and barriers.
SAFETY RULES
Connect only in accordance with the diagram presented in the
manual. Improper connections may be dangerous, it can damage
the controller, and loss of the warranty.
Connecting the device to a power supply that does not meet the
quality requirements specied in EN 50081-1, EN 50082-1, UL508,
EN 60950 will invalidate the warranty.
DANGER! Risk of electric shock! Even with the device turned o,
the outputs may be live. All assembly work should be ALWAYS
performed with the disconnected power circuit.
GARAGE, SLIDING AND SWING GATES AND DOOR CONTROLLER
Disconnect the installation supply voltage before installing the controller.
Remember that any mounting works should be carried out when the mains
voltage is disconnected (switch o the mains fuse or disconnect the power
cord from the mains socket).
1INSTALLATION - BASICS
The controller should be installed in a place protected against adverse
environmental conditions, protected from third party access - in the ush box
or inside the enclosure of the controlled device. Remember that metallic
elements (wires, housing parts) have a negative inuence on the range of the
device, and consequently the comfort of use. It is recommended that the
device be mounted in a stable and xed position.
Read the diagram and then proceed to install the controller. Pay particular
attention to the designation of the controller connectors. Start by connecting
the + 12V / + 24V power wires (red or black with a white dotted line) and GND
(black).
Paying attention to the polarity, connect the inputs controlling the engine
control panel. Depending on the control panel, will be necessary to connect
one or two inputs. The controller output O1 is destined for control in the open
/ stop / close mode. The O2 output is an auxiliary output, applicable in the
control panel requiring a connection stop circuit when the motor works, or
may be used as an additional function, e.g. "wicket" if the control panel is
equipped with this functionality.
control with ÎĽWiFi technology
from any place in the World
CONNECTION DIAGRAM
If the motor has electromechanical limits switch, it is possible to receive
feedback from the controller, indicating the position of the motor in the
positions "Open" (intermediate position) "Closed". To do this, connect one of
the pins IN1 of the controller to the connector of the motor control panel
which indicates the closed position of the motor (usually FTC, SWC, FC) on the
other hand the second of the pins should be connected to the corresponding
common signaling. One of the IN2 input pins should be connected to the
connector indicating the open position of the motor (usually FCO, SWO, FA),
while the other one should be connected to the corresponding common
signaling. The connection polarity of the controller inputs is not signicant.
IN1
5 - 24V
IN2
12-24V
AC/DC
PWR
O2
made in
Europe
O1
12 - 24V
S1 S2
push-button
It is necessary to connect the right pin of the given output
(O1 / O2) so that it has a higher potential than the left pin.
In case of an inverted connection, due to the internal
construction, it will connect the output which may cause
the movement of the motor even without control it. In this
situation, it is necessary to reverse the pair of wires
connected inside output.
Pay attention to the maximum output current
capacity - the control current cannot exceed 20mA
per output. Overloading the output will cause
irreparable damage to the controller.
Information advanced for installers in relation to the
output polarity, when is connected to engines control
panels for which the scheme is not available.
3ACCESS POINT AND WIFI NETWORK SETTINGS
Once you turn on the controller for the rst time, you can proceed to its
further conguration. Being connected to the WiFi network emitted by the
device, in the control panel of the wBox application select the device, then go
to “Settings” (icon at the top-right corner of the screen).
You can change the name of the device that is displayed in the wBox
application. In addition, you can change the name and password of its
generated WiFi network. Remember that changing the network name or
password will disconnect the device immediately after you click the "Save"
button, so re-connect to the device using the newly assigned network name
and password.
You can add the controller to your home WiFi network to control it through
this home network or from anywhere in the World. To do this, in the "Connect"
settings section, select a network name from the list and press "Connect". If is
required, enter the WiFi network password. During the connection of the
controller to your home network, the phone / tablet may disconnected from
the network. In this case, you will need to reconnect your phone / tablet to the
controller network.
Please remember that in order to control the device outside the local WiFi
network, from anyplace in the World by using the wBox application, the
option "Remote access enabled" in the controller settings must be set to "Yes".
Once you've nished conguring the WiFi network, you can disconnect your
phone/tablet from the controller network and connect your mobile device
directly to your home WiFi network. The control from the wBox application
will work the same way as when the phone / tablet is connected to the
controller network. If the user leaves the local network, for example, leaving
home or using the mobile data, the wBox application will signal this state as
"Remote mode". In this case, the devices can be controlled, but for security
reasons settings are not available.
Go to "Settings" (icon in the upper right corner of the screen), go to the "Gate
settings" section and select the appropriate option in the "Gate type" eld.
Then, depending on your control panel, select the function of the second
(auxiliary) output. After saving the settings, go to the main panel by clicking
the arrow in the upper left corner. Test the controller work of by clicking the
gate / door icon - the control panel should force the motor to move.
In the "Gate settings" section, in the eld "Address (URL) of the MJPEG stream"
you can enter the URL stream of the camera IP which supervise the motor.
Download the free wBox application. If you have an Android mobile device,
you will nd the application in the Play Store. For iOS devices the application is
in the App Store.
By using your mobile phone or tablet, connect it to the device wireless
network. To do this, enter to your smartphone or tablet settings, then go to
setting of the WiFi network and nd the network name "gateBox-xxxxxxxxxx”
where xxxxxxxxxx is the serial number of the device. Connect to this network.
Turn on the wBox application. A device will appear at the top of the screen. To
add it to the application, click on "+" on the right side of the name. To pre-
congure the controller, click on the default device name.
2 FIRST START
You can also set the conguration using the web browser
of your phone / tablet. After connecting to the wireless
network of the controller, turn on the browser and go
website www.blebox.eu
The meaning states of the limits detected in the IN1 / IN2
inputs (it mean which of the IN1 or IN2 inputs indicates the
closed position and which the open position) can be
changed in the controller settings menu in the option
"Replace inputs".
The limit state is detected if there is a current owing
between the IN1 connectors and between the IN2 does
not. Analogously, the opposite state will be detected when
there is no current owing between the IN1 connectors,
and will ow between the IN2 connectors. Any other
conguration of the current ow is equivalent to the
motor position beyond the limit positions. Inputs IN1 and
IN2 have no specic polarity, they are galvanically isolated
from the rest of the controller. The range of allowable
voltages on the individual input pairs is 12 - 24V AC / DC.
Information advanced for installers regarding inputs,
when is connected to a motor control panel for which is
not available diagram.
After making sure that the device is connected in accordance with the
diagram and that there are no metal components near the controller which
may accidentally cause short-circuit, start the device by turning on the power
(turning on the mains fuse or connecting the power cord to the power outlet).
In case you need to make changes in the advanced controller settings,
click on "Show advanced" button. Will appear additional options.
In the "Gate output type" eld, the output behavior can be changed between
the normally open output (NO - when the output is not shorten) or normally
closed (NC - in other words the contact pair is shorten, opens when the user
presses the control button). It is also possible to adjust the duration of the
impulse in the output - between 0.1 sec. to 15 seconds - after a single press of
the control button. The option "Outputs swap" allows you to correct the order
of pairs of wires without switching them again, for example when the gate
control wire has been connected to the O2 output instead of under O1.
Go to the main panel by clicking the arrow in the upper left corner. If the
motor position sensor circuit has been connected, test the gate work - click on
the gate / door icon, the control panel should force the motor to move. Note
the blue border around the icon. If the motor is in an intermediate position,
the icon's border will be half blue and half gray. The limit position in the
"Open" state is indicated by a gray border and in the "Closed" state by a blue
border.
If you need to change the advanced settings of the controller associated with
the inputs, return to the controller settings, go to the "Gate settings" section
and then click the "Show advanced" button. Will appear additional options. If
despite the correct wiring, the controller can not detect the motors position,
is possible to change the detection method of the limit switches connected to
IN1 / IN2 inputs. If the state of the motor position is detected inversely, i.e. the
motor is physically in the closed position and the visualization indicates that it
is open, it means that the pairs of wires in the IN1 / IN2 inputs have been
changed, so the option should be changed in the eld "Inputs swap (IN1, IN2)"
to "Enabled".
ADDITIONAL INFORMATION
SOFTWARE UPDATE
To update the software in the controller, connect it to your home WiFi network
(see "Access Point and WiFi Network Settings" section) which is connected to
the Internet. Go to “Settings” (icon at the top-right corner of the screen) and
click the "Get new rmware" button in the nal section on settings. Wait about
1 minute, do not close the interface and don’t perform other actions. The
device will download the latest software. The software version number,
hardware version and device identier can be read at the bottom of the
settings screen.
4ACCESS MANAGEMENT
Return to the controller settings. In the "Access management" section, you can
also create accounts for the gate users. This provides additional protection for
access to the controller. If you create users, the option of adding a controller to
the wBox application and its control will be available only after entering the
correct login and password.
To add a new user, in the "Access management" section, press the "Add"
button and then ll in the new window the "User name" and "Password" elds
and press the "Save" button. If at least one user account is added, the
controller will require logging each time the controller is added to the wBox
application. Only after logging in the controller, it will be possible to control
the motor.
made of polyurethane composition not
containing halogens, self-extinguishing for
thermal class B (130 °C)
12 - 24V AC / DC
20 mA
2
logical
12 - 24V AC / DC
yes
< 2 W
2
open collector, pulse
IP20
TECHNICAL SPECIFICATIONS
direct connection (as Access Point),
Wi-Fi connection via a standard router,
connection with access from any location
in the world (requires only access
to the Internet)
Apple iPhone, Apple iPad, iPad Mini,
Android, computers and mobile devices
supporting HTML5
2.4 GHz
ÎĽWiFi, compatible with WiFi, 802.11g
bi-directional, encrypted
for more information visit our website
www.blebox.eu
or send us an email to: info@blebox.eu
support is available at support@blebox.eu
housing
supply voltage
energy consumption
number of outputs
type of outputs
maximum load
communication standard
transmission type
mode
number of inputs
inputs type
voltage range
galvanic isolation
protection level
radio frequency
compatible devices


Produktspezifikationen

Marke: Blebox
Kategorie: Nicht kategorisiert
Modell: gateBox

Brauchst du Hilfe?

Wenn Sie Hilfe mit Blebox gateBox benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Blebox

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-