Installaon Instrucons
Contemporary and Stylish
Keep instrucons for future reference
Glen Dimplex Australia proudly supports the acvies of Landcare Australia through its membership of the AHHA
B500
B800
CONTENTS
1. INSTALLATION ................................................................... 1
1.1. IMPORTANT INFORMATION .................................... 1
1.2. INSTALLING THE HEATER ......................................... 2
1.2.1. Posioning the Heater 2 ........................................
1.2.2. Standard Installaon ........................................... 2
1.2.3. Corner Installaon 2 ..............................................
1.2.4. Floor Protector .................................................... 2
1.3. REDUCING CLEARANCES TO COMBUSTIBLES .......... 3
1.4. INSTALLING THE FLUE .............................................. 3
1.5. INSTALLING THE BAFFLE PLATE ............................... 4
1.6. INSTALLING THE FIRE BRICKS 5 ..................................
1.7. TECHNICAL DRAWINGS 6 ...........................................
1. INSTALLATION
1.1. IMPORTANT INFORMATION
The unit must be installed according to all manufacturers’
instrucons included in manual. The manufacturer is not this
liable for installaons that do not meet the requirements
outlined in this manual.
Most building regulatory authories in Australia require any
wood heater installaon to comply with Installaon Standard
AS/NZS 2918. Dierent states and councils may have varying
regulaons. Check local building regulaons before installing
the appliance.
All Blaze wood heaters have been tested to ensure they will
meet the appropriate safety standard requirements if the
instrucons in this manual are followed. As the safety and
emissions performance can be aected by altering the
appliance, no modicaons are allowed without wrien
permission from the manufacturer.
WE RECOMMEND THAT THE INSTALLATION OF YOUR BLAZE
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLER.
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING
CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
THE INSTALLATION INSTRUCTIONS IN THIS MANUAL
APPLY TO THE BLAZE B50 AND B80 FREE-STANDING 0 0
WOOD HEATER MODELS.
THEY HAVE BEEN TESTED FOR EMISSIONS AND
EFFICIENCY AND COMPLY ACCORDING TO AS/NZS 4012 &
AS/NZS 4013.
1.2. INSTALLING THE HEATER
1.2.1. Posioning the Heater
Review the necessary clearances specied in this secon
before considering where to posion the heater.
Also check the praccability of installing the ue system in
relaon to any obstrucng roof beams before posioning the
heater.
The clearance distances can only be reduced if the
surrounding walls are made of non-combusble material such
as stone, brick or concrete. If non-combusble material,
distance can be reduced to 100 mm. Alternavely, shielding of
the wall(s) can reduce clearances (refer to next secon for
more detail).
Clearances to combusble surfaces vary depending on the
type of ue shielding used, and if oponal side shields have
been added to the heater.
1.2.2. Standard Installaon
Dimensions given in the table and image below represent the
minimum clearance (in millimetres) to combusble materials.
A = Minimum oor protector width
B = Minimum oor protector depth from door opening
X = Rear clearance
Y = Side clearance
Dimensions (mm)
X
Y
A
B
125
350
900
300
125
300
1000
400
1.2.3. Corner Installaon
Dimensions given in the table and image below represent the
minimum clearance (in millimetres) to combusble materials.
A = Minimum oor protector width
B = Minimum oor protector depth from door opening
Z = Corner clearance
Dimensions (mm)
Z
A
B
100
900
300
100
1000
400
1.2.4. Floor Protector
Unless the heater will be standing on a heat resistant oor
such as concrete slab with slate or les, it will be necessary to
provide a oor protector.
The minimum required dimensions for the oor protector are
shown in the previous secons. It may be desirable, for
example aesthec reasons, for the oor protector to be larger
than these minimum dimensions.
The oor protector shall be constructed of non-combusble
material no less than 15mm thick and with a thermal
conducvity not greater than 0.33W/m °K, eg. compressed
cement sheet.
The oor protector may be laid directly on the combusble
oor.
For more details and variaons on oor protectors refer to
AS/NZS 2918 Clause 2.2, 3.3.1, & 3.3.2.