Bionaire BOH1501W Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Bionaire BOH1501W (44 Seiten) in der Kategorie Heizungen. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/44
English 2
Deutsch/German 4
Français/French 7
Español/Spanish 9
Nederlands/Dutch 12
Svenska/Swedish 14
Suomi/Finnish 16
Norsk/Norwegian 18
Polski/Polish 21
EKKHNIKA/Greek 23
česky/Czech 26
Magyar/Hungarian 28
РУССКИЙ/Russian 31
Italiano/Italian 33
Português/Portuguese 36
Dansk/Danish 38
INSTRUCTION MANUAL
BENUTZERHANDBUCH
MANUEL D’UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIEHANDLEIDING
BRUKSANVISNING
KÄYTTÄJÄN OHJEKIRJA
BRUKERHÅNDBOK
INSTRUKCJA OBSŁUGI
NÁVOD K OBSLUZE
HASZNÁLATI UTASÍTÁS
PYKOBOДCTBO ПО ЭКСПЛУАТАЦИИ
MANUALE DI ISTRUZIONI
MANUAL DE INSTRUÇÕES
BRUGERVEJLEDNING
OIL FILLED
RADIATORS
pure indoor living
MODELS# BOH1501, BOH2001
BOH1501W, BOH2001W
© 2009 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All rights reserved. Distributed by
Holmes Products (Europe) Ltd., 1 Francis Grove, London SW19 4DT, United Kingdom. Printed in PRC
© 2009 Sunbeam Products, Inc. faisant affaires sous le nom de Jarden Consumer Solutions. Tous droits réservés.
Distribué par Holmes Products (Europe) Ltd., 1 Francis Grove, London SW19 4DT, United Kingdom. Imprimé en RPC
Belgium: +32 38 70 86 86
Czech Republic: +420 48 513 03 03
Finland: +358 98 70 870
Germany: +49 89 5480195-0
Hungary: +36 1 37 17 970
Latvia +371 7514081
Lithuania +370 (52) 772388
Netherlands: +31 793 41 77 71
Poland: +48 22 847 8968
Russia: +7 095 334 82 21
Slovakia: +421 41 723 47 09
Spain: +34 902 051 045
Holmes Products (Europe) Ltd.
1 Francis Grove
London SW19 4DT
England
Fax: +44 (0)20 8947 8272
Email: enquiriesEurope@jardencs.com
Website address: www.bionaire.com
UK - Free phone Customer Service Helpline – 0800 052 3615
Holmes Products France
1015, Rue du Maréchal Juin
Z.I Vaux - Le - Pénil
77000 Melun – France
Phone: +33 1 64 10 45 80
Fax: +33 1 64 10 02 32
FRANCE - SERVICE CONSOMMATEURS
SPR-030309 P/N: 128112 Rev. A
BOH1501-I_IB_REV.qxd:BPH1515I06MLM1.qxd 3/19/09 11:55 AM Page 6
BOH1501/2001
Fig. 1
Fig. 2
A
B
C
E
F
G
L
H
I
J
0
1
2
3
Fig. 3
D
L
G
K
M
N
O
BOH1501-I_IB_REV.qxd:BPH1515I06MLM1.qxd 3/19/09 11:55 AM Page 3
2 3
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety
precautions should always be taken including
the following:
1. Before connecting the heater, check that the
voltage indicated on the rating plate
corresponds to the main voltage in your
home/office.
2. WARNING: In order to avoid overheating,
do not cover the heater ( ) Reference to
product.
3. DO NOT position the heater directly under a
power socket.
4. DO NOT use this heater in the immediate
surroundings of a bath, a shower or a
swimming pool.
5. If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
agent or similarly qualified person in order to
avoid hazard. The heater contains no user
serviceable parts. Should the product suffer
damage or breakdown, it must be returned to
the manufacturer or their service agent.
6. Under the environment with electrical fast
transient, the product may malfunction.
7. DO NOT use this heater with a
programmer, timer or any other device
that switches the heater on automatically,
since a fire risk exists if the heater is
covered or positioned incorrectly.
8. Only touch the heater with dry hands.
9. DO NOT use this heater outdoors.
10. DO NOT position where it can be touched by
children, especially the very young.
11. Allow a safe area around the heater away
from furniture or other objects; at least 50
cm from the top and sides and 200 cm at
the front. The heater is to be placed at least
3m from water source.
12. DO NOT use this heater when it is lying on
its side.
13. DO NOT use the heater in rooms with
explosive gas (e.g. petrol) or while using,
oxygen, inflammable glue or solvent (e.g.
when gluing or varnishing parquet floors,
PVC etc.)
14. DO NOT insert any objects into the heater.
15. Keep the mains cord at a safe distance from
the main body of the heater.
16. If overheating should occur, the built-in
overheating safety device will switch off
the heater.
17. DO NOT place the cord under a rug.
18. The heater cannot be used adjacent to
curtains or combustible material. Curtains or
combustible material may be burned if the
heater was installed incorrectly.
19. This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
20. This heater is filled with a precise quantity of
special oil. Repairs requiring opening of the
oil container are only to be made by the
manufacturer or his service agent who
should be contacted if there is an oil leak;
21 when scrapping the heater, follow the
regulations concerning the disposal of oil.
DESCRIPTIONS (See Fig. 1, 2 & 3)
A. Heated Fins
B. Vents
C. Handle
D. Front Panel
E. Cord Storage
F. Power Cord
G. Front Stand
H. Control Knob
I. Power Light
J. Thermostat Knob
K. Q Shape Screw
L. Casters
M.Foot Plate
N. Wing Nut
O. U-bolt
Technical Specifications
BOH1501/W
Wattage: 1500W
BOH2001/W
Wattage: 2000W
ASSEMBLY INSTRUCTIONS (See Fig. 3)
Please make sure the heater has not been
plugged into any electricity outlet.
Carefully remove heater from box. Some
acessories are packed internally. Please make
sure you have all of the following acessories
prior to throwing away packaging.
1 Foot Plate with 2 casters (M&L), 1 Front Stand (G),
and 1 Q shape Screw (K) and 1 Wing Nut (N).
Note: This unit is for FLOOR USE ONLY.
1. Turn the heater upside down and you will see
one U-bolt (O) with wing nut over the last joint
of the heater.
ENGLISH 2. Unscrew the wing nut (N) from the U-bolt (O).
3. Place one hole of the foot plate (M) to the L
shape of the U-bolt (O) and the other hole of
the foot plate into the other end of the U-bolt,
then screw on the wing nut (N).
4. Place the front stand (G) on the bottom of the
radiators front panel, and secure it with the Q
shape screw (K). This front stand (G) is not
meant to be removed once it is attached to
the bottom of the unit.
5. After installation of the front stand (G) and foot
plate (M) with casters (L) turn the heater the
right way up: the heater is now ready for use.
OPERATING INSTRUCTIONS
(See Fig. 1&2)
1. Set the unit to the OFF (O) position.
2. Plug in heater. The Power Light (I) will
illuminate and remain lit until the heater
is unplugged.
3. Set the Thermostat Knob (J) all the way to
the right.
4. Turn the Control Knob (H) to desired level of heat.
NOTE: When the heater is in use, it is
normal that the heater cycles ON and OFF,
this is to maintain your desired temperature.
After using the heater, turn the Control Knob (H)
to “0” position, turn the Thermostat Knob (J) to
lowest temperature position and unplug the
heater from the socket.
Turn the Control Knob to desired heat setting.
BOH1501/W: 1 -600W, 2 -900W, 3-1500W
BOH2001/W: 1 -800W, 2 -1200W, 3 -2000W
SETTING THE THERMOSTAT
1. Set the Thermostat control all the way to max.
2. When the desired temperature/comfort level is
reached, turn the thermostat control
anti-clockwise to lower position or until the
heater stops operating.
3. The control will now automatically maintain
the pre-set temperature level by turning the
heater ON and OFF.
NOTE: The Power light will remain lit during
operation.
NOTE: It is normal for the heater to cycle ON
and OFF as it maintains the preset
temperature.
ANTI-FROST GUARD INSTRUCTION
If you plug in the heater, it will start working at the
lowest temperature setting (When thermostat
control is in the lowest temperature position, the
temperature will be maintained at 5° C, thus the
heater will be in the off status unless the room
temperature is lower than 5° C. If the room
temperature is lower than 5° C, the heater will
automatically start working and will keep turning
on & off all the time, maintaining its ambient
temperature of 5° C.
NOTE: Unit must be unplugged for it to be
fully off
TIP OVER PROTECTION
When the unit is accidentally knocked over, or
tilts on one side at more than a 45° angle; it
will instantly shut off. To reset, simply place the
heater in an upright position.
STORAGE TIPS
If the heater is not required for long periods, for
example during the summer, it should be stored
at room temperature; in a dry place and
preferably covered to prevent the accumulation
of dust and dirt.
FITTING A REPLACEMENT PLUG FOR
U.K. AND IRELAND ONLY.
If the plug is not suitable for the socket outlets in
your home, it can be removed and replaced by a
plug of the correct type. For correct type and
correct installation please refer to "Installation of
a plug" below.
INSTALLATION OF A PLUG – Applicable to
U.K. and Ireland.
NOTE: If you are in any doubt about wiring
and the installation of the plug. Please
contact a qualified electrician.
NOTE: If a 13A 3-pin plug is fitted, it must be
an ASTA approved plug, conforming to the
BS1363 standard. Replacement 13 amp fuse
must also be BSI or ASTA approved.
The wires in this mains lead are coloured as such:
GREEN & YELLOW - Earth
BROWN - Live
BLUE - Neutral
Please note that the colour of these mains wires
may not correspond with the colour markings
that identify the terminals in your plug.
BOH1501-I_IB_REV.qxd:BPH1515I06MLM1.qxd 3/19/09 11:55 AM Page 2
Produktspezifikationen
Marke: | Bionaire |
Kategorie: | Heizungen |
Modell: | BOH1501W |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Bionaire BOH1501W benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Heizungen Bionaire
12 Oktober 2024
10 Oktober 2024
13 Juli 2024
Bedienungsanleitung Heizungen
- Heizungen Infiniton
- Heizungen Clatronic
- Heizungen Emerio
- Heizungen Tristar
- Heizungen Nedis
- Heizungen SilverCrest
- Heizungen Profile
- Heizungen Adler
- Heizungen Bestron
- Heizungen AEG
- Heizungen Ardes
- Heizungen Gorenje
- Heizungen Jata
- Heizungen Klarstein
- Heizungen Teesa
- Heizungen Vox
- Heizungen Aresa
- Heizungen Thomson
- Heizungen Black And Decker
- Heizungen Trotec
- Heizungen Mestic
- Heizungen Heinner
- Heizungen Maestro
- Heizungen Coleman
- Heizungen Daewoo
- Heizungen Saivod
- Heizungen Eurom
- Heizungen DCG
- Heizungen Rowenta
- Heizungen Sencor
- Heizungen DeLonghi
- Heizungen Scarlett
- Heizungen Anslut
- Heizungen Gemini
- Heizungen Termozeta
- Heizungen Haverland
- Heizungen Honeywell
- Heizungen Logik
- Heizungen Dimplex
- Heizungen EWT
- Heizungen Alpatec
- Heizungen AKO
- Heizungen Beha
- Heizungen LEX
- Heizungen Mellerware
- Heizungen Swan
- Heizungen Orbegozo
- Heizungen Kambrook
- Heizungen Tayosan
- Heizungen Vornado
- Heizungen Clarke
- Heizungen ElectriQ
- Heizungen Holmes
- Heizungen Končar
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024