Getting Started
1. Remove safe from packaging and remove Manual and
all accessories that came with the safe.
2. Insert emergency key into key access, and turn
clockwise to unlock and open the safe.
3. Unscrew battery compartment and insert 4 AA
batteries. (Bolts are extended). Do not mix old and
new batteries.
4. Place any fingerprint on scanner. Few beeps will be
heard and red flashes will be seen, then bolts will
retract, the safe will open.
Note: If safe opens with few beeps and red flashes, this
means safe is in factory default mode: ANY Fingerprint
can open the safe.
Fingerprint Registration
1. With safe open and bolts retracted, press and release
initialization button located inside the safe and place
desired finger on fingerprint scanner.
Successful Registration
2 beeps will be heard and 2 green flashes will be seen.
Unsuccessful Registration
2 quick beeps will be heard along with red flash.
Test Registered Fingerprint
1. With safe door open, press “0” on keypad to extend
the bolts, the safe is locked.
2. Press “0” to wake up safe and place Registered
Fingerprint on the scanner. If safe bolts retract and 2
beeps and green flash is seen, it means the
registration was successful. If safe opens with several
beeps and red flash is seen then registration was
unsuccessful. Follow steps under Fingerprint
Registration to register safe.
Pin Code Registration
1. Enter Current Pin Code (Default Pin Code:
“12312312312”) then immediately press “3” on keypad,
both red and green light should be seen.
2. Enter new desired Pin Code 4 – 11 digits. If less than
11 digits, press initialization button on the back of the
safe to finish. 1 long beep will be heard and green light
will be seen.
Note: Pin Code CANNOT start with “0”
See reverse side for more information 8/15
BC443
WARNING
Test Registered Pin Code
1. With safe door open, press “0” on keypad to extend
the bolts, the safe is locked.
2 Enter Registered Pin Code. If there are beeps and
green light flashes, bolts retract then registration was
successful. If there are two short beeps and red light
flashes, bolts do NOT retract then registration was
unsuccessful. Follow steps under Pin Code
Registration to register desired Pin Code.
Close / Open Safe Door
Open Safe Door with Fingerprint
Press “0” on keypad to wake up the safe and place
Registered Finger on the scanner. Safe should open.
Open Safe Door with Pin Code
Enter Registered Pin Code and safe should open.
Closing Safe Door
Please push door against the body of the safe and press
“0” on keypad. Bolts should extend and Safe door is now
locked.
Silent Mode
Sound Off
Press and hold initialization button until 1 beep is
heard along with green flash. Sound is now disabled.
Note: Door Open Alarm will not beep when safe is in
silent mode, but green light will flash once every
4 seconds.
Sound On
Press and hold initialization button until 1 beep is
heard along with green flash.
Door Open Alarm
Safe will start beeping 1 min after safe door has been
opened. Please close safe door or turn safe to silent
mode to turn off alarm.
* Actual model may vary
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
User’s Manual for Biometric Keypad Safe
Read all instructions before using this safe
- Safe can be opened by either Fingerprint, PIN code,
and/or Emergency Keys.
- If user resets the safe to Factory Default mode: ANY
fingerprint and Factory Default PIN code can open
the safe.
- If safe is in factory default mode Red flash will be seen
along with several beeps when accessing the safe.
- Register BOTH Fingerprint and PIN code to disable
factory default mode.
- Register at least two different fingerprints and test a few
times before closing the safe door.
- Test with a non-registered fingerprint. If the safe opens,
the safe is still in Factory Default mode.
- Avoid leaving safe door open and unattended; it will allow
unauthorized individuals to add their fingerprints and/or
reprogram the safe, gaining full access to the safe and
the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the safe,
test registered fingerprints every 6 months.
E. Indicator Lights
F. Emergency Key Access
G. Key Pad
G
A
B
D
E
C
F
Resetting the Safe
Take all the batteries out of the safe, press and hold
the initialization button inside the safe while
re-inserting the batteries, keep holding initialization
button until 3 beeps are heard and green flash is seen.
Test Safe to See if it is Reset
With Fingerprint Press “0” on keypad and place any
fingerprint on fingerprint scanner. Few beeps will be
heard and red flashes will be seen, then bolts will
retract, the safe will open.
With Pin Code Press “12312312312” on keypad, beep
will be heard and green flash will be seen, the bolts
will retract and safe should open.
Low Battery Warning
An alarm sound and red flash will be seen when trying to
access safe. Safe may allow access still, but batteries should
be replaced as soon as possible.
Note: Can use 9v battery as an external power source. Place
9v battery under fingerprint module, touching the metal
contacts under the fingerprint module. Safe should power up,
if not switch the polarity of the 9v battery.
Care and Maintenance
- To maximize the security and performance of the safe, keep
Fingerprint Scanner clean; use a dry cloth to remove any
smudges or prints off the Fingerprint Scanner after
each use.
- Test registered fingerprints and PIN code every 6 months.
- Keep liquids away from the control panel. Spills on the
control panel will cause damage and possibly electric shock.
- Secure safe in a proper area to prevent from falling and
causing damage or injury.
- DO NOT disassemble the product. For all repairs, contact
BARSKA Customer Service.
- DO NOT use chemicals or cleaning agents to clean
the safe.
User’s Manual for Biometric Keypad Safe
Read all instructions before using this safe
Mounting Instructions
The safe may be mounted to a wall or floor. Be aware of
the load bearing. Failure to do so can result in personal
injury and/or damage to property. Use appropriate tools
when performing work and always use eye protection.
Wall Mounting
Do not mount the safe without anchoring to the wall.
- Find the studs in the wall, at your desired location. Most
studs are 16 inches or 24 inches apart.
- Check the wall for concealed wires or pipes.
- Measure the location of the pre-set drill holes; mark
their exact position onto the wall ensuring that the
studs or anything else behind will not interfere.
- Drill the appropriate size holes for the anchors you
are using.
- Carefully press the anchor into the holes at this time.
- Mount the safe by running screws from inside of the
safe and securing to anchors; ensure the safe is
mounted securely.
Floor Mounting
- Use proper drill tools depending on the type of floor you
are mounting the safe (wood, tile, or concrete).
- Measure the location of the pre-set drill holes; mark
their exact position onto the floor.
- Drill the appropriate size holes for the anchors you
are using.
- Carefully press the anchor into the holes at this time.
- Mount the safe by running screws from inside of the
safe and securing to anchors; ensure the safe is
mounted securely.
Biometric Keypad Safe
1 YEAR LIMITED WARRANTY
BARSKA warrants this new safe to be free of original defects in
material and/or workmanship under normal use for a period of twelve
(12) months from the date product is received by purchaser. This
warranty does not include damage caused by improper installation or
maintenance. Damage from misuse, abuse, accident (such as
dropping), normal wear and tear, fire, flood, or acts of nature. Damage
from service or repairs other than those performed by BARSKA.
Labor, cost and shipping charges for the removal and replacement of
defective parts beyond the initial twelve-month warranty period. All
transportation and shipping charges. Removing or altering the seal
under any circumstances will automatically void the warranty.
This warranty is limited to original purchaser and is not transferable.
This warranty applies only to products purchased in the United States.
Please email info@barska.com or call 1.888.666.6769 for Return
Merchandise Number (RMA#) before any returns. The RMA number
must appear on the outside of the shipping package. Product must be
packed carefully and sturdily in its original packaging to prevent
damage in transit and returned freight pre-paid to:
BARSKA OPTICS
Repair Department
855 Towne Center Drive
Pomona, CA 91767
Please include all of the following when returning BARSKA products
for service and/or replacement:
1. Please write your complete details (Name, Address, Telephone #,
E-mail address, RMA#, etc.)
2. Purchase receipt or Proof of Purchase. (Original/Copy)
3. A brief explanation of the defect.
4. A Check/Money Order of cover inspection, shipping and handling.
Charges are as follows:
Biometric Keypad Safe BDK100 - $40.00
Biometric Keypad Safe BDK200 - $40.00
Biometric Keypad Safe BDK300 - $60.00
Biometric Keypad Safe BDK400 - $60.00
*Please allow 6-8 weeks for delivery.
BARSKA will examine and test returned product and repair or replace
defective part(s) or units with new part(s) or a new unit if necessary
within the warranty period. Purchaser is required to remit $40.00 to
BARSKA for return shipping and handling at time product is returned.
If repair is required after warranty period expiration, purchaser will be
charged for replacement parts and return shipping.
BARSKA® Optics shall not be liable for any consequential, incidental
and/or contingent damages whatsoever. We will not pay shipping,
insurance or transportation charges from you to us, or any import
fees, duties and or taxes. This warranty supersedes all previous
BARSKA® Optics warranties.
©2015 BARSKA®
855 Towne Center Drive | Pomona, CA 91767
(t) 888.666.6769 | (f) 909.445.8169 | www.barska.com
Produktspezifikationen
Marke: | Barska |
Kategorie: | Gewölbe |
Modell: | AX12842 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Barska AX12842 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Gewölbe Barska
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
Bedienungsanleitung Gewölbe
- Gewölbe Hama
- Gewölbe Philips
- Gewölbe Guzzanti
- Gewölbe Thule
- Gewölbe Conrad
- Gewölbe FERM
- Gewölbe Topcraft
- Gewölbe Dometic
- Gewölbe Abus
- Gewölbe Olympia
- Gewölbe Yale
- Gewölbe Perel
- Gewölbe Workzone
- Gewölbe Westfalia
- Gewölbe Burg Wächter
- Gewölbe Honeywell
- Gewölbe Filex
- Gewölbe First Alert
- Gewölbe Master Lock
- Gewölbe Phoenix
- Gewölbe Rottner
- Gewölbe Salvus
- Gewölbe SentrySafe
- Gewölbe Juwel
- Gewölbe Toolland
- Gewölbe Kidde
- Gewölbe Royal Sovereign
- Gewölbe SereneLife
- Gewölbe Sygonix
- Gewölbe Fluke
- Gewölbe VARO
- Gewölbe Duralock
- Gewölbe EasySafe
- Gewölbe Fichero
- Gewölbe FireKing
- Gewölbe Jewel
- Gewölbe Kreator-Varo
- Gewölbe M-Locks
- Gewölbe Nauta
- Gewölbe Oxloc
- Gewölbe Protector
- Gewölbe ROMA
- Gewölbe Sentry
- Gewölbe Sistec
- Gewölbe SMC
- Gewölbe Steren
- Gewölbe Technomax
- Gewölbe Avanti
- Gewölbe Olymp
- Gewölbe Challenge
- Gewölbe Suncast
- Gewölbe Kreator
- Gewölbe NOFIRE
- Gewölbe Homak Security
- Gewölbe CAWI
- Gewölbe Rottner Tresor
- Gewölbe Winholt
- Gewölbe Stamony
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
5 Oktober 2024
5 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024