Barska AX11780 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Barska AX11780 (2 Seiten) in der Kategorie Gewölbe. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
See reverse side for more information
5/13
BC344
1. INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
2. FINGERPRINT REGISTRATION
IMPORTANT:
The safe is in Factory Default mode, ANY fingerprint can
open the safe. Only successful registered fingerprint can
terminate Factory Default mode
1. With safe door open, press and release Initialization
Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint – repeat steps 1 - 2
3. TEST A REGISTERED FINGERPRINT
1. With safe door open, turn Handle (H) counter clockwise to
lock the safe
- Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should not open
2. If the Handle (H) turned with a non-registered fingerprint,
registration was unsuccessful; and safe remains in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION
3. Press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should open
4. CLOSE/OPEN SAFE DOOR
CLOSE: Close door
- Turn Handle (H) counter clockwise to lock the safe
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
5. BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
– RELEASE the Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
followed by 1 beep – RELEASE the Initialization Button
6. OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided Allen wrench
2. Insert Emergency Key into key access, push and turn key
counter clockwise, and turn Handle (H) clockwise to open
the safe
NOTE: Store Emergency Keys in a secure place, NOT inside
of the safe
7. OPEN SAFE WITH EXTERNAL BATTERY PACK
Use this option when internal batteries are low
1. Insert 4 AA batteries
2. Plug into External Battery Access (J)
3. Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
8. DELETE ALL STORED FINGERPRINTS /
RESET TO FACTORY DEFAULT MODE
1. Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
2. Press and release Wake-Up Button (F) a few times until no
beeps are heard
3. Press and HOLD the Initialization Button (A)
- Re-insert batteries, on the 4th battery you will hear 1
beep, followed by 2 consecutive beeps indicating safe is
in Factory Default mode
4. RELEASE Initialization Button (A)
5. Repeat steps 1-3 if a total of 3 beeps are not heard
6. Restore Battery Compartment (B) cover
7. All fingerprints stored in the safe have been deleted
NOTE: The safe is in Factory Default mode, ANY fingerprint
can open the safe
F
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
F. Wake-Up Button
G. Logo Plate and Emergency
Key Access
H. Handle
I. External Battery Pack
(batteries not included)
J. External Battery Access
* Actual model may vary
A
B
C
D
E
G
HH
HJ
I
L
o
c
k
U
n
l
o
c
k
WARNING
- New Safe is in Factory Default mode, ANY fingerprint
can open the safe. Only successful registered
fingerprint can terminate Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe remains in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
Read all instructions before using this safe.
User’s Manual for Biometric Safe
F
BARSKA warrants this new safe to be free of original defects in
material and/or workmanship under normal use for a period of twelve
(12) months from the date product is received by purchaser. This
warranty does not include damage caused by improper installation or
maintenance. Damage from misuse, abuse, accident (such as
dropping), normal wear and tear, fire, flood, or acts of nature. Damage
from service or repairs other than those performed by BARSKA.
Labor, cost and shipping charges for the removal and replacement of
defective parts beyond the initial twelve-month warranty period. All
transportation and shipping charges. Removing or altering the seal
under any circumstances will automatically void the warranty.
This warranty is limited to original purchaser and is not transferable.
This warranty applies only to products purchased in the United States.
Please email info@barska.com or call 1.888.666.6769 for Return
Merchandise Number (RMA#) before any returns. The RMA number
must appear on the outside of the shipping package. Product must be
packed carefully and sturdily in its original packaging to prevent
damage in transit and returned freight pre-paid to:
BARSKA OPTICS
Repair Department
855 Towne Center Drive
Pomona, CA 91767
Please include all of the following when returning BARSKA products
for service and/or replacement:
1. Please write your complete details (Name, Address, Telephone #,
E-mail address, RMA#, etc.)
2. Purchase receipt or Proof of Purchase. (Original/Copy)
3. A brief explanation of the defect.
4. A Check/Money Order of to cover inspection, shipping$90.00
and handling.
*Please allow 6-8 weeks for delivery.
BARSKA will examine and test returned product and repair or replace
defective part(s) or units with new part(s) or a new unit if necessary
within the warranty period. Purchaser is required to remit to $90.00
BARSKA for return shipping and handling at time product is returned.
If repair is required after warranty period expiration, purchaser will be
charged for replacement parts and return shipping.
BARSKA® Optics shall not be liable for any consequential, incidental
and/or contingent damages whatsoever. We will not pay shipping,
insurance or transportation charges from you to us, or any import
fees, duties and or taxes. This warranty supersedes all previous
BARSKA® Optics warranties.
Biometric Safe
1 YEAR LIMITED WARRANTY
BC325 5/13
9. LOW BATTERY WARNING
1. When the door is closed and 3 repetitive beeps are heard,
and Indicator Lights (E) flash red, it indicates the batteries
are low
2. Replace batteries immediately
- Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
- Insert 4 new AA batteries and restore Battery
Compartment (B) cover
NOTE: All registered fingerprints remain stored
10. CARE AND MAINTENANCE
- To maximize the security and performance of the safe, keep
Fingerprint Scanner (D) clean; use a dry cloth to remove
any smudges or prints off the Fingerprint Scanner after
each use
- Test registered fingerprints every 6 months
- Keep liquids away from the control panel. Spills on the
control panel will cause damage and possibly electric shock
- Secure safe in a proper area to prevent from falling and
causing damage or injury
- DO NOT disassemble the product. For all repairs, contact
BARSKA Customer Service
- DO NOT use chemicals or cleaning agents to clean the safe
11. MOUNTING INSTRUCTIONS
The safe may be mounted to a wall
or floor. Be aware of the load
bearing. Failure to do so can result in
personal injury and/or damage to
property. Use appropriate tools when
performing work and always use eye
protection
Wall Mounting
Do not mount the safe without
anchoring to the wall
- Find the studs in the wall, at your
desired location. Most studs
are 16 inches or 24 inches apart
- Check the wall for concealed wires
or pipes
- Measure the location of the pre-set drill holes; mark their
exact position onto the wall ensuring that the studs or
anything else behind will not interfere
- Drill the appropriate size holes for the anchors you are using
- Carefully press the anchor into the holes at this time
- Mount the safe by running screws from inside of the safe
and securing to anchors; ensure the safe is
mounted securely
Floor Mounting
- Use proper drill tools depending on the type of floor you are
mounting the safe (wood, tile, or concrete)
- Measure the location of the pre-set drill holes; mark their
exact position onto the floor
- Drill the appropriate size holes for the anchors you are using
- Carefully press the anchor into the holes at this time
- Mount the safe by running screws from inside of the safe
and securing to anchors; ensure the safe is
mounted securely
Mounting Holes
* Actual model may vary
Produktspezifikationen
Marke: | Barska |
Kategorie: | Gewölbe |
Modell: | AX11780 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Barska AX11780 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Gewölbe Barska
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
Bedienungsanleitung Gewölbe
- Gewölbe Hama
- Gewölbe Philips
- Gewölbe Guzzanti
- Gewölbe Thule
- Gewölbe Conrad
- Gewölbe FERM
- Gewölbe Topcraft
- Gewölbe Dometic
- Gewölbe Abus
- Gewölbe Olympia
- Gewölbe Yale
- Gewölbe Perel
- Gewölbe Workzone
- Gewölbe Westfalia
- Gewölbe Burg Wächter
- Gewölbe Honeywell
- Gewölbe Filex
- Gewölbe First Alert
- Gewölbe Master Lock
- Gewölbe Phoenix
- Gewölbe Rottner
- Gewölbe Salvus
- Gewölbe SentrySafe
- Gewölbe Juwel
- Gewölbe Toolland
- Gewölbe Kidde
- Gewölbe Royal Sovereign
- Gewölbe SereneLife
- Gewölbe Sygonix
- Gewölbe Fluke
- Gewölbe VARO
- Gewölbe Duralock
- Gewölbe EasySafe
- Gewölbe Fichero
- Gewölbe FireKing
- Gewölbe Jewel
- Gewölbe Kreator-Varo
- Gewölbe M-Locks
- Gewölbe Nauta
- Gewölbe Oxloc
- Gewölbe Protector
- Gewölbe ROMA
- Gewölbe Sentry
- Gewölbe Sistec
- Gewölbe SMC
- Gewölbe Steren
- Gewölbe Technomax
- Gewölbe Avanti
- Gewölbe Olymp
- Gewölbe Challenge
- Gewölbe Suncast
- Gewölbe Kreator
- Gewölbe NOFIRE
- Gewölbe Homak Security
- Gewölbe CAWI
- Gewölbe Rottner Tresor
- Gewölbe Winholt
- Gewölbe Stamony
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
5 Oktober 2024
5 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024