SCX25A
OVERVIEW
The SCX25A is a professional studio condenser microphone with an elegant design
and a patented capsule suspension system. Uniquely shockmounted within an
intricate machined brass ring, the SCX25A capsule is completely isolated from
the mic body and electronics. By successfully minimizing acoustic reflections and
diffractions, the SCX25A delivers a pure, open-air sound with exceptional detail
and realism.
With a smooth uniform frequency response from 20 Hz - 20 kHz, the SCX25A is very
consistent when responding to on and off-axis signals, exhibiting excellent phase
coherence and minimal proximity effect. The SCX25A has a wide cardioid polar
pattern which enables the sound engineer the opportunity to blend the sound of
the instrument or vocal with the sound of the room. Other features include a
one-inch (25 mm) gold vapor capsule, miniaturized electronics and an extremely
small footprint. The SCX25A will handle SPL in excess of 135 dB and will provide
up to 20 dB of ambient noise rejection. For a lower output option, the SCX25ALO is
available with a max SPL limit of 150 dB and a sensitivity of 4.9 mV/Pa.
In addition to vocals, the SCX25A is ideally suited to capture acoustic instruments
such as piano, guitar, vibes, woodwinds, brass, percussion toys, drum overheads, choir,
orchestra and symphony sectionals.
The SCX25A is manufactured with a precision machined brass body, innovative
capsule suspension system, steel mesh grill, black multi-layer class A’ liquid finish and
gold plated XLR connector.
MODEL VARIATIONS
SCX25ALO - Low output SCX25A
SCX25AMP - Matched pair
SCX25APS - Piano Miking system
SUPPLIED ACCESSORIES
Metal adapter to accommodate 3/8” mic stands
CASEWOOD - Foam lined wooden case
DCLIP - Heavy-duty nylon molded snap on clip
OPTIONAL ACCESSORIES
APS2 - Two-channel 48 V phantom power supply. 110 V switchable to 240 V.
Detachable power cord.
DFLEX - Dual pivot rim mounted clip with extra wide butterfly jaws.
STANDKD - Short pedestal stand with telescoping boom arm.
SMT25 - Low profile shock mount system with nylon cable and thumbscrew for
positioning.
PD133 - Optional two-layer mesh pop diffuser for controlling acoustic plosives.
CBL20 - 20’ premium XLR-XLR balanced mic cable. Quad conductor, twisted pair with
braided shield for conductivity. 6 mm PVC jacketed.
P1 - Carrying pouch.
Studio Condenser
Microphone
SCX25A
FEATURES
· Premium large diaphragm studio microphone for
studio or live sound
· Delivers pure open air sound
· Shock mounted capsule suspension system
· Designed, machined, assembled and tested in
the USA
· 3 year warranty
APPLICATIONS
·Piano
·Acoustic instruments
·Drum overheads
·Ambient room mic
·Studio, lead, and backing vocals
·Voice over
·Choir
·Orchestra
CASEWOOD DCLIP APS2 DFLEX STANDKD SMT25 PD133 CBL20 P1
Hi
Lo
FREQUENCY RESPONSE
POLAR PATTERNS
ARCHITECT AND ENGINEER SPECIFICATIONS
The microphone shall be of the condenser type with a cardioid polar pattern.
The microphone shall operate on 48-52 volts phantom power and the nominal
output impedance shall be equal to 200 ohms at 1 kHz. The microphone shall
have a sensitivity of 28 mV / Pa at 1 kHz. The microphone shall have a maximum
SPL level of ≥135 dB with a THD of 0.5%. The microphone shall have a fine steel
mesh grill and a body machined of brass with dimensions of 21 mm diameter at
the base, 51 mm in diameter at the widest point on the grill and 148 mm in length.
OPERATION AND MAINTENANCE
The SCX25A is a low impedance microphone and should be plugged into a “mic
level” input on your console, mixer, or recording device. The SCX25A requires
phantom power and will NOT operate without phantom power voltage (48
Volts recommended) which is available on most professional mic preamps and
mixing devices. If phantom power is not available on your equipment, use a
phantom power supply such as the Audix APS2.
Avoid plugging or unplugging the microphone from a PA system unless the
channel is muted or the volume of the system turned down. Failure to do so may
result in a loud “popping noise which could seriously damage the speakers in
the PA system or studio monitors.
The SCX25A is manufactured to exacting specs with road worthy construction.
However, the capsule is highly sensitive and should be handled with care.
Avoid extreme temperatures and be sure to store your microphone in the case
provided when not in use. Moisture of any kind can adversely affect the sound
and performance of your microphone.
USER TIPS
The correct side: Note that the front of the microphone element is on the same
side as the printing. This side of the microphone should be facing towards the
sound source.
The SCX25A is a world class recording microphone with very high output and
sensitivity. Therefore, it is not intended to be used at very close range, especially
with instruments that produce high sound pressure levels. For high SPL, use
SCX25ALO.
For acoustic instruments: In general, the working range should be
from 1-2 feet, depending on the instrument and room acoustics
For voice: the minimum distance is 8-10 inches for a single voice.
For group vocals: Place microphone 2-3 feet away.
For piano: For live performance and live recordings, it is sometimes
recommended to use the short stick or closed lid in order to minimize the
surrounding instruments from “bleeding” into the piano mics. In these cases, it
is suggested to use the Audix DFLEX mounting clips which enable the SCX25A
to be mounted right on to the rail of the piano. The mics can be positioned
horizontal to the sound board, typically one towards the front of the keyboard
and one towards the rear of the keyboard over the bass strings.
Further miking techniques may be found at www.audixusa.com.
ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
www.audixusa.com
503.682.6933 Fax: 503.682.7114
Audix Corporation 9400 SW Barber St. Wilsonville, OR 97070
ver 3.0 04-16
PRODUCT REGISTRATION: Please register your product online at www.audixusa.com/docs_12/about/product_registration.shtml.
SERVICE AND WARRANTY:
This microphone is under warranty for a period of 3 years to be free of defects in material and workmanship. In the event of a product failure due to materials or
workmanship, Audix will repair or replace said product at no charge with proof of purchase. Audix does not pay or reimburse shipping costs for warranty repairs or returns. The warranty excludes
any causes other than manufacturing defects, such as normal wear, abuse, environmental damage, shipping damage or failure to use or maintain the product per the supplied instructions. No
Implied Warranties: All implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose are hereby excluded. The liability of Audix, if any,
for damages relating to allegedly defective products shall be limited to the actual price paid by Dealer for such products and shall in no event include incidental or consequential damages of
any kind. Should your microphone fail in any way, please contact the Audix Service department at 503.682.6933. A Return Authorization is required before returning any product. OTHER THAN
THIS WARRANTY, AUDIX MAKES NO WARRANTIES, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS, THE USE OF THE PRODUCTS, THE PERFORMANCE OF THE PRODUCTS. AUDIX SHALL
NOT BE LIABLE FOR SPECIAL INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES ARISING FROM OR BASED ON THE SALE, USE, STORAGE OR DISPOSAL OF THE PRODUCTS, AUDIX’S
SERVICE WORK, BREACH OF WARRANTY, BREACH OF CONTRACT. NEGLIGENCE, OR ANY OTHER THEORY OF LIABILITY, EVEN IF AUDIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
DIMENSIONS (mm)
SPECIFICATIONS
SCX25A
Transducer Type
Condenser
Frequency Response
20 Hz - 20 kHz
Polar Pattern
Cardioid
Output Impedance
200 ohms
Sensitivity
28 mV / Pa @ 1k
Equivalent Noise Level
14 dB (A-weighted)
Signal to Noise Ratio
80 dB
Maximum SPL
≥135 dB
Dynamic Range
121 dB
Power Requirements
48-52 V phantom
Connector
3-pin XLRm
Polarity
Positive pressure on diaphragm
produces positive voltage on
pin 2 relative to pin 3 of output
XLR connector
Materials / Finish
Machined Brass / Black Finish
Weight
244 g / 8.6 oz
Length
148 mm / 5.8 in


Produktspezifikationen

Marke: Audix
Kategorie: Nicht kategorisiert
Modell: SCX25A
Produktfarbe: Schwarz
Übertragungstechnik: Kabelgebunden
Höhe: 148 mm
Energiequelle: Gleichstrom
Typ: Instrumenten-Mikrofon
Geräteschnittstelle: XLR-3
Gehäusematerial: Messing
Mikrofon-Frequenz: 20 - 20000 Hz
Ausrichtung des integrierten Mikrofons: Kardioide
Tragetasche: Ja
Eingangsspannung: 48 - 52 V
Mikrofongewicht: 244 g
Output Widerstand: 200 Ohm
Stimmenmagnetspuele Typ: Verflüssiger
Mikrofon Signal-to-Noise Ratio (SNR): 80 dB
Äquivalenter Schallpegel: 14 dB
Empfindlichkeit (1kHz): 28 mV/Pa
Mikrofon Dynamikbereich: 121 dB