INSTALLATION AND
OPERATING INSTRUCTIO NS
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS
tralPool Pumps As
CTX Series, E Series
BX Series & FX Series
www.astralpool.com.au
sales@astralpool.com.au
Inst243 AstralPool Pump Instructions V - 07 20
2
Inst243 AstralPool Pump Instructions V - 07 20
3
GENERAL
A high performance, high head pump ideally suited for the modern pool or spa with extensive equipment such as
chlorinators, heaters and in îoor cleaning.
Note:
The appliance is not intended for use by young children or inîrm person without supervision. Please ensure that young
children are supervised to ensure that they do not play with the appliance.
FEATURES
- Continuous duty rated motor
- Precision reinforced moulded high head impeller, giving extra performance
- Single piece moulded body for added strength and longer life
- Rapid priming diîuser quickly corrects loss of water îow
- Quick and easy disassembly for servicing
- Large capacity basket with easily removed lid
FX PUMPS FLOW RATES
Inst243 AstralPool Pump Instructions V - 07 20
4
E-SERIES PUMPS FLOW RATES
CTX PUMPS FLOW RATES
Inst243 AstralPool Pump Instructions V - 07 20
5
BX PUMPS FLOW RATE
INSTALLATION OF BX, CTX & E SERIES PUMPS
E-SERIES
CTX SERIES
Inst243 AstralPool Pump Instructions V - 07 20
6
FX SERIES
BX SERIES
Inst243 AstralPool Pump Instructions V - 07 20
7
A. Plan position of pump so that it will be:
1. Free of water îooding, such as in a sump, garden hollow, ditch or at the bottom of a bank.
2. On a stable base so that:
a) The pump is not left suspended by its îttings, causing a leak or failure with loss of wate r.
b) Movement through vibration is restricted
c) No strain is put on attaching pipe or other expensive equipment
3. Accessible for maintenance and easily removed for service.
4. Breathing space. Pump should not be crowded which will prevent cooling airîow from fan. Overheating due
to lack of cooling voids warranty.
5. Within reach of power point without extension cables as plugs liable to corrosion, shorting, etc .
6. At a minimum height of suction lift of water from pool surface to pump inlet.
B. For best pump performance keep suction pipe length as short as possible with minimum number of bends and use
50mm PVC suction pipe for 750W (1.0hp) to 1700W (2.0 hp). On 3.0 hp models a 65mm or 2 x 50mm suctions
should be used.
C. Minimum pipe diameters should be used on the following pumps.
40mm - E 140, E190, E230, CTX180
50mm - E 290, CTX280, CTX360, CTX400, CTX610, BX1.0, BX1.5, BX2.0, BX3.0
D. Secure the barrel unions supplied into the attaching pipe work, using approved priming îuid and solvent cement as
normal practice, coating both surfaces. NOTE: Always wear protective gloves when handling and using glue and
priming îuid. Ensure no excess adhesive runs into the union proper aîecting the sealing or removal abilities.
Allow 24 hours to dry before starting pump.
E. Install isolation valves before the pump section and after equipment if the pump is below the water level of the
pool.
F. For pump installations 500mm above water level, it generally requires a foot valve at the pool or check valve in the
suction line. Suction lines must be installed below water level until just in front of pump location and vertical riser
used to reach pump inlet. AstralPool pumps are rated to a maximum head of 25 meters however refer to your
pump s data plate for actual achievable pressure. â
G. All pumps will operate quieter and perform more eîciently if a straight length of 450mm pipe is plumbed
horizontally into the front of the pump.
H. Water temperature not to exceed 45 degrees C.
I. Pumps must be either
- supplied by an isolating transformer, or
- supplied through a residual current device (RCD) with a rated residual operating current not
exceeding 30mA.
INSTALLATION OF FX SERIES PUMPS
A. Plan position of pump so that it will be:
1. Below the pool or spa water level unless pump is primed to be a secondary pump.
2. Free of water îooding, such as in sump, garden hollow, ditch or at bottom of bank with run oî.
3. On a stable base so that:
a) The er. pump is not left suspended by its îttings, causing a leak or failure with loss of wat
b) Movement through vibration is restricted.
c) No . strain is put on attaching pipe or other expensive equipment
4. Accessible for maintenance.
5. Easily removed for service.
6. Breathing space Pump should not be crowded which will prevent cooling airîow from fan. Overheating .
due to lack of cooling voids warranty.
7. Within reach of power point without extension plugs liable to corrosion, shorting, etc.
B. For best pump performance keep suction pipe length as short as possible with minimum number of bends and
use 50mm PVC suction pipe for 750W (1hp) or larger pumps.
C. Minimum pipe diameters should be used on the following pumps:
40mm - FX140, FX190, FX 250
50mm - FX29 FX340, FX520 0,
D. Secure the barrel unions supplied into the attaching pipe work, using approved priming îuid and solvent
cement as normal practice, coating both surfaces. NOTE: Always wear protective gloves handling and using
glue and priming îuid. Ensure no excess adhesive runs into the union proper aîecting the sealing or removal
abilities. Allow 24 hours to dry before starting pump.
E. Install isolation valves before the pump section and after equipment .
Inst243 AstralPool Pump Instructions V - 07 20
8
F. All pumps will operate quieter and perform more eîciently if a straight length of 450mm pipe is plumbed
horizontally into the front of the pump.
G. Water temperature not to exceed 45 degrees C.
H. AstralPool pumps are rated to a maximum head of 25 meters however refer to you pumps data plate for actual
achievable pressure.
I. Pumps must be either
- supplied by an isolating transformer, or
- supplied through a residual current device (RCD) with a rated residual operating current not
exceeding 30mA.
3 PHASE PUMP INSTALLATION
Only a qualiîed Electrician may connect or disconnect this pump to or from a power supply. The Pump must be connected
by means of îxed wiring (to AS/NZS 3000:2007) so that the IP rating is maintained when doing so. Electrician must check
the direction of rotation of the pump at the time of installation, refer to arrow on the seal plate to conîrm correct rotation.
Required size Power Cable for Power connection,
Minimum 3 x 1.5 sq mm cable 600/1000v with Min 1.5mm Dia conductors and with a Min Outer Diameter of 9.0mm to a
Maximum Diameter 10.5mm dia to be used.
The Pump is not suitable for îex and plug connection.
1. Connect power to motor.
2. Ensure that pump is empty of all water.
3. Momentarily apply power to motor and check rotation direction of motor matches that of the arrow located on the
rear of the pump seal plate.
4. If motor is rotating in the opposite direction to arrow on pump, correct phase wiring.
5. Once rotation is correct, îll pump with water, prime as described below and test pump operation.
OPERATION OF BX, CTX & E SERIES PUMPS
1. Prime pump if hair and lint pot is dry as follows Close oî valve on suction line if present. Remove lint pot lid. Fill â
lint pot and chamber with water. Replace and secure lint pot lid and seal.
2. Open all valves, allowing fluid to îow through pump.
3. Switch on power to pump.
4. If some îow of water does not establish within one half minute, switch oî and prime pump again. If pump does
not prime within 3 attempts, check all suction connections for sealing. If these are satisfactory, a check or foot
valve is required to hold water for prime.
5. If the water îow through pump is always tedious to obtain at start-up after cleaning the lint basket, then an
examination of the system to establish a reason and correct the cause is recommended. Eg. Check valve, air leaks,
faulty seal, cracked lint pot lid, etc.
6. A non return valve is supplied loose in the basket of the pump (CTX and E Series only). To install, place between
the outlet barrel union tail and the discharge of the pump. The non return valve should be located so that the flap
can swing upwards into the union tail. The non return valve should be installed on spas equipped with cartridge
îlters, any time multiple pumps are operating oî one suction or return line or any installation where a back îow of
water may occur when the pump is shut down. The non return valve will reduce the performance of the pump
slightly.
Notes: The pump is not intended for use by young children or inîrm persons without supervision. Please ensure that young
children are supervised to ensure that they do not play with the pump.
To avoid a safety hazard, the supply cord if damaged, must only be replaced by AstralPool, or its service agent or a suitably
qualiîed person.
OPERATION OF FX SERIES PUMP
1. Open all valves, allowing fluid to îow through pump.
2. If an air lock occurs and no water appears to îll pump housing once the valves have been opened, release outlet
barrel union slowly until a small amount of water escapes from the pump then re-tighten.
3. Switch on power to pump.
4. If some îow of water does not establish within one half minute, switch oî and repeat procedure 3 again. If pump
does not prime within 3 attempts, check all valves and jets are in the open position.
Notes: The pump is not intended for use by young children or inîrm persons without supervision. Please ensure that young
children are supervised to ensure that they do not play with the pump.
Inst243 AstralPool Pump Instructions V - 07 20
9
To avoid a safety hazard, the supply cord if damaged, must only be replaced by AstralPool, or its service agent or a suitably
qualiîed person.
MAINTENANCE
AstralPool pumps are designed to operate for extended periods with minimal attention or maintenance. Following are the
periodic maintenance requirements:
1. Keep the lint basket clean empty it regularly. Blocked lint basket or suction pipe and no water îow can cause â
overheating with consequent pipe and pump components failure and meltdown.
2. Apply suitable waterproof grease to the lint pot âOâ ring to ensure positive seal.
3. Ensure electrical passage for cooling airîow to prevent fusing or shock hazards.
4. Maintain clear passage for cooling airîow to prevent overheating of motor.
5. Maintain water in good chemical balance.
6. Do not allow quantities of sand of grit to continuously pass through pump to prevent âsand blastingâ erosions (use
îlter sock in lint basket if sand, etc. is being picked up by vacuum.)
7. Do not over tighten strainer lid. Never use a tool or handle to tighten lid, the lid is designed to prevent this from
happening.
8. Do not add pool salt, chlorine, acid or other chemicals directly to your skimmer. This may result in damage to your
pump and could void your warranty.
Maintenance of your pump
Maintenance Schedule: Your new product incorporates moving parts and withstands high velocity water with
chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and
maintenance. Performing these checks and maintenance will identify parts that have worn and require
repair/replacement before further serious damage is sustained. A small amount of regular care and attention to your
pool equipment will help ensure long life and trouble free performance.
To protect against extremes of temperature, your unit is vented to allow expensive electronics to cool.
Ants and some insects are often attracted to the warmer, dry environment inside the enclosure. We
recommend that, with power turned oî, you spray a surface insecticide on the surfaces surrounding the
control to prevent ant and insect ingress. Repeat every three months or as necessary.
Timing
Maintenance Check
Service action (if required)
Weekly or sooner
Check and empty hair and lint basket
Empty leaves and debris
Three Monthly
Check Lid O ring and inlet/outlet O rings for
leaks
Isolate Pump, turn power oî, clean and
grease O rings or replace if necessary
Three Monthly
Check surroundings for leaves, debris and
îżooding
Check for inserts/ants
Remove debris and rectify if any îooding
Turn oî power to pump,Spray a surface
insecticide on the surfaces around the unit
to prevent ant and insect ingress.
Three Monthly
Check for leaks from underneath pump
Call Service technician, repair or replace
mechanical seal and motor bearings if
necessary
Important note: Regular maintenance is important to ensure long life and trouble free performance of your pool
equipment. If unable to perform the maintenance yourself, contact your local AstralPool oîce who will arrange a trained
service technician to perform the maintenance for you.
Record your Equipment details here for quick reference:
Model No.: ____________________________
Serial No.: ____________________________
Inst243 AstralPool Pump Instructions V - 07 20
10
Electrical SpeciïŹcations
All Astral Pool pumps have double insulation on the water circuit for maximum protection and safety. Pumps manufactured
by Astral Pool use P2 rated capacitors for protection against îre.
Inst243 AstralPool Pump Instructions V - 07 20
11
NOTES:
Inst243 AstralPool Pump Instructions V - 07 20
12
Fluidra Group Australia PTY LTD
219 Woodpark Road
Smithîeld, N.S.W 2164
Australia
ABN 87 002 641 965
Produktspezifikationen
Marke: | AstralPool |
Kategorie: | pomp |
Modell: | CTX 360 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit AstralPool CTX 360 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp AstralPool
18 August 2024
17 August 2024
14 August 2024
13 August 2024
13 August 2024
12 August 2024
11 August 2024
11 August 2024
10 August 2024
10 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp KĂ€rcher
- pomp GĂŒde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp ZĂ©fal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung fĂŒr -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024