Arnold Rak OTD 2 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Arnold Rak OTD 2 (20 Seiten) in der Kategorie Thermostat. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/20
57118 05/09 (DJU)
English
German
Russian
Polish
Type OTN2 / OTD2
with room or
floor sensor
ENGLISH . . . . . . . . . . . . . page 3
GERMAN . . . . . . . . . . . . . page 7
RUSSIAN . . . . . . . . . . . . . page 11
POLISH . . . . . . . . . . . . . page 15
3
Technical data
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC ±15% 50 Hz
Max.pre-fuse ........................................16A
Built-in circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-pole, 16 A
Output relay . . . . . . . . . . . . . . . . . . . . . . . .Make contact - SPST - NO
Output .................................Max.16A/3600W
Controlprinciple ...................................ON/OFF
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+0/+40°C
Difference/hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.4°C
Economy temperature . . . . . . . . . . . . . . . . . . . . . . .5°C (2-8°C OTD2)
- control voltage signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC
Frost protection temperature . . . . . . . . . . . . . . . . . . . . . .5°C absolute
- control voltage signal via rectifier diode . . . . . . . . . . . . . . .230 V AC
Rangelimits .....................................min./max.
Sensor fault protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20°C
Ambient operating temperature . . . . . . . . . . . . . . . . . . . . . . .0/+40°C
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H/84, W/84, D/40 mm
Enclosurerating ......................................IP21
The thermostat is maintenance free.
Classification
The product is a Class II appliance (with reinforced insulation) and
must be connected as follows:
Term. 1: Live (L1) 230 V ±15%, 50/60 Hz
Term. 2: Neutral (L2)
Term. 3–4: Max. load 16 A, 3600 W
MICROLINE electronic thermostat for installation in standard wall
box. The thermostat allows the required temperature to be set within
the range 0-40°C. An LED indicates whether heating is active. The
thermostat is suitable for ELKO and NORWESCO systems S-16, RS-
16 and UNI-10. An extra frame is supplied with the unit.
MICROLINE PRODUCT PROGRAMME
OTN2-1991 with floor sensor
OTN2-1999 with built-in room sensor
OTD2-1999 with built-in room sensor and external limitation sensor
CE MARKING
Applied standards
EN 61000-6-3, EN 61000-6-2, EN 60 730-1 and EN 60730-2-9.
The product may only be used if the complete installation complies
with current directives.
The thermostat must only be installed by an authorised electrician.
If the product has been damaged in any way, e.g. during transport, it
must be inspected and checked by authorised personnel before being
connected to the power supply.
The product carries a manufacturer's warranty if installed in
accordance with these instructions and applicable regulations.
Type OTN2 / OTD2 with room or floor sensor English


Produktspezifikationen

Marke: Arnold Rak
Kategorie: Thermostat
Modell: OTD 2

Brauchst du Hilfe?

Wenn Sie Hilfe mit Arnold Rak OTD 2 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermostat Arnold Rak

Bedienungsanleitung Thermostat

Neueste Bedienungsanleitung für -Kategorien-