Ardo BASIC-F50INOX Bedienungsanleitung

Ardo Dunstabzugshaube BASIC-F50INOX

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Ardo BASIC-F50INOX (24 Seiten) in der Kategorie Dunstabzugshaube. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
COOKER HOOD
U S E R I N S T R U C T I O N S
DUNSTABZUGSHAUBE
G E B R A U C H S A N W E I S U N G
HOTTE PER CUISINE
M A N U E L D  U T I L I S AT I O N
G E B R U I K S A A N W I J Z I N G
AFZUIGKAP
M A N U A L D E U T I L I Z AC I Ó N
CAMPANA EXTRACTORA
M A N U A L D O U S U Á R I O
CAPPA ASPIRANTE
M A N U A L E D  U S O
VENTILATOR
B R U K E R V E I L E D N I N G
B R U G E R V E J L E D N I N G
LIESITUULETIN
O D H G I E S C R H S E W S
OKAP
I N S T R U K C J E U Z Y T K O W N I K A
ODSAVAC
N AV O D NA P O Ù Z I T Ì E
PARAELSZIVÓ
H A S Z N Á L AT I Ú T M U T A T Ó
GB
D
F
NL
E
I
P
S
N
GR
RUS
PL
CZ
H
FIN
DK
COIFA ASPIRANTE
SK
ARE
ODSÁVAC PÁR
N Á V O D NA P O U  I T I E
3LIK0092
480
45
240
150
45
C
21
A
B
Z
395
520
23
max 80 cm
G
F
1Mt.
D
90°
A
A
G
F
L
D
90°
90°
L
2Mt.
Fig.2 Fig.3
Fig.1
2
ENGLISH
GENERAL
Carefully read the following impor tant information regarding
installation safety and maintenance. Keep this information booklet
accessible for further consultations.
The appliance has been designed as a exhausting version
(external exhaust) or as a filter version (internal air recycle) cooker
hood.
SAFETY PRECAUTION
1. ake care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the air in the
environment and are supplied by other than electrical energy, as
the cooker hood removes the air from the environment which a
burner or fireplace need for combustion.
The negative pressure in the environment must not exceed 4 Pa
(4 x 10 -5 bar).
Provide adequate ventilation in the environment for a safe
operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
2. WARNING!!
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch the light bulbs after appliance use
C) Flambè cooking is prohibited underneath the cooker hood
D) Avoid free flame, as it is damaging for the filters and a fire
hazard
E) Constantly check food frying to avoid that the overheated
oil may become a fire hazard
F) Disconnect the electrical plug prior to any maintenance.
INSTALLATION INSTRUCTIONS
• Electric Connection
The appliance has been manufactured as a class II, therefore no
earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indicated on
the description label. Where a plug is provided, the cooker hood
must be installed in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between
contacts, in line with the electrical load and local standards, must
be placed between the appliance and the network in the case of
direct connection to the electrical network.
• The appliance must be installed at a minimum height of 650 mm
from an cooker stove.
If a connection tube composed of two parts is used, the upper
part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor
used to circulate hot air or for evacuating fumes from other
appliances generated by other than an electrical source.
ATTENTION: should the lamps not work, make sure they are well
tightened.
MOUNTING OF THE HOOD IN THE LOWER PART OF AN
HANGING CUPBOARD
Drill 4 holes of 6 mm. diameter at the bottom of the hanging cupboard
as showed in the drawing fig.1.
Fit the hood in the cabinet with 4 screws, which are appropriate to that
kind of cupboard.
The appliance is provided with 2 air outlets, one which is in the upper
part and the other on the back. Both of them can be used according to
your requirements. A connecting ring (C), which to join the connecting
pipe to,and a cover (A) to close the air outlet, which is not used, are
supplied.
3
MOUNTING OF THE HOOD ON THE WALL
Drill 4 holes on the wall, which correspond to the position (B-Z) of the
drawing fig. 1.
Hang the hood on the 2 holes by using the screws and dowels with
expanding plug ,which are aprropriate for that kind of wall (ex.
concrete, plasterboard etc.)
Fix definitely the hood through the 2 security holes (Z).
CHANGING FROM EXHAUSTING HOOD TO FILTERING ONE
In order to make this change, demand a set of carbon filters to your
dealer. Active carbon filters are necessary to depurate the air, that will
be released in the room. Filters are not washable; they cannot be
regenerated and have to be replaced at most every 4 months. The
saturation of the activated charcoal depends on the more or less
prolonged use of the hood, on the type of cooking and on the regularity
of cleaning the grease filter. The filter (D) has to be applied to the
aspirating group, which is inside the hood hiting the centre of the group
with it and turning it of 90 degrees until the stop click is heard to lock
it. Remove the grill (G) to carry out this operation. Close with the
appropriate covers the upper and back air outlets; turn the small lever
(L) from the position (A) to the position (F). In this way the hood is
ready for the filtering function.
USE AND MAINTENANCE
• It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes
after cooking is terminated in order to completely eliminate cooking
vapours and odours.
The proper function of the cooker hood is conditioned by the regularity
of the maintenance operations, in particular, the active carbon filter.
• The anti-grease filters capture the grease particles suspended in the
air, and are therefore subject to clogging according to the frequency of
the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the filter
at a maximum of 2 months by carrying out the following instructions:
- Remove the filters from the cooker hood and wash them in a solution
of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes. This
is not cause for customer complaint nor replacement of panels.
• The active carbon filters purify the air that is replaced in the
environment. The filters are not washable nor re-useable and must be
replaced at maximum every four months. The saturation of the active
carbon filter depends on the frequency of use of the appliance, by the
type of cooking and the regularity of cleaning the anti-grease filters.
• Clean the fan and other surfaces of the cooker hood regularly
using a cloth moistened with denatured alcohol or non abrasive
liquid detergent.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.
ENGLISH


Produktspezifikationen

Marke: Ardo
Kategorie: Dunstabzugshaube
Modell: BASIC-F50INOX

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ardo BASIC-F50INOX benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dunstabzugshaube Ardo

Bedienungsanleitung Dunstabzugshaube

Neueste Bedienungsanleitung fĂźr -Kategorien-