Exhaust Fan with Light
AKLC70 Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualied
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturers guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A
SHOWER STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill with Glass Light Lens
1 - Damper Assembly (attached)
2 - #8 Screws
2 - Lockwashers
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Choose the location for your fan. To ensure the best air and sound performance, it
is recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise
and airflow restrictions. This fan will require at least 6 of clearance in the ceiling or wall, "
and will mount through drywall up to 3/4 thick. The fan can be mounted directly to the "
joist using the mounting tabs on the sides of the housing or between 16” on center joists
using the 4 provided mounting rails.
SECTION 2
New Construction
1. Mounting Rail Installation: Install the rails on the housing and position the housing next
to the joist. Using the gauge on the fan’s housing, line up housing so that it will be flush
with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to
the joists and slide the housing into the final position (Figure 1).
2. Mounting Tab Installation: Using the gauge on the fan’s housing, line up housing so
that it will be flush with the finished ceiling. Position the fan so that the tabs rest flat
against the joist and secure with four nails or screws (not provided) to ensure proper
installation .(Figure 2)
SECTION 3
Existing Construction
1a. Mounting Rail Installation: Set housing in position between the joist and trace an outline
onto the ceiling material Set housing aside and cut opening, being careful not (Figure 3).
to cut or damage any electrical or other hidden utilities. Install the rails on the housing and
position the housing in the previously cut hole so that it is flush with the finished ceiling.
Secure the ends of the rails to the joists with nails or screws (not provided) (Figure 1).
www.airkinglimited.com
6728087 Rev. D 1-16 2 of 12
1b. Mounting Tab Installation: Position housing against the joist and trace an outline of the
housing onto the ceiling material Set housing aside and cut opening, being (Figure 4).
careful not to cut or damage any electrical or other hidden utilities. Place housing next
to the joist and insure that it is flush with the finished ceiling. Secure with four nails or
screws (not provided) to ensure proper installation (Figure 2).
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Connect the ducting to the fan’s duct collar . Secure in place using tape or (Figure 5)
screw clamp. Always duct the fan to the outside through a wall or roof cap.
NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is
designed to only fit one way.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE
IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not require the removal of the
fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the
blower assembly and internal wiring compartment. Both methods are equally effective.
1a. Remove the wire compartment cover screw and place External Wire Compartment:
cover in a secure place .(Figure 6)
Housing
Joist
Mounting Rails
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
5/8"
1/2"
1/4"
3/8"
1b. Internal Wire Compartment: Remove the screw holding the blower assembly in place. Lift
up on the assembly and tilt it at a 45° angle to remove from the housing Remove (Figure 7).
the wire compartment cover screw and place the cover in a secure place (Figure 8).
NOTE: If the fan motor plug is
connected to the fan housing
receptacle, unplug so the
blower assembly can be
completely removed.
2a. Wiring Fan/Light Independently: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and two hot
(black lead connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
2b. From where you have access to inside the fan’s junction box, connect the one white wire
from the house to both the white wire from the fan’s light receptacle and the white wire
from the fan’s exhaust receptacle. Connect the first black wire from the wall switch to the
red wire from the fan’s light receptacle. Connect the second black wire from the switch to
the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire
from the fan’s grounding screw . Use approved methods for all connections.(Figure 9)
3a. Wiring Fan/Light together: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and one hot
(black lead connected to the switch). Secure the electrical wires to the housing w ith an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
www.airkinglimited.com
6728087 Rev. D 1-16 3 of 12
3b. From where you have access to inside the fan’s junction box, connect the one white wire
from the house to both the white wire from the fan’s light receptacle and the white wire
from the fan’s exhaust receptacle. Connect the black wire from the wall switch to both
the red wire from the fan’s light receptacle and the black wire from the fan’s exhaust
receptacle. Connect the ground wire from the house to the green wire from the fan’s
grounding screw Use approved methods for all connections.(Figure 10).
4. Carefully tuck wire back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
SECTION 6
Completing the Installation
1. If the fan’s blower assembly was removed during the wiring process, reinstall the blower
by reversing the directions in in .Step 1b Section 5 Wiring
2. Insert the fan’s plug into the receptacle .(Figure 7)
3. Remove light lens from grill as follows:
Gently twist the light lens counter clockwise to release from the grill AKLC70RCB:
(Figure 11).
AKLC70SLN, AKLC70SLW: (Figure 12) Slide the glass light lens out either side of the grill .
AKLC70SNS, AKLC70DRSB, AKLC701, AKLC702, AKLC703: Unscrew the finial at the top
of the glass light lens. Make sure you support the light lens as you unscrew (Figure 13).
Remove glass light lens from grill by pulling the tension springed hook AKLC70DW:
outward and sliding the glass out of the hooks .(Figure 14)
Figure 6
Screw
Wire
Compartment
Cover
Figure 7
Screw
Wire
Compartment
Cover
Plug
Screw
Figure 9
Supply
from
house
Neutral (White)
Ground (Green or Bare)
Hot
(Black)
Hot (Red)
Figure 10
Supply
from
house Neutral (White)
Ground (Green or Bare)
Hot (Black)
Hot (Red)
Figure 8
Figure 12
Glass Lens
Figure 13
Glass Lens
Finial
Figure 11
Lens


Produktspezifikationen

Marke: Air King
Kategorie: Ventilator
Modell: AKLC701

Brauchst du Hilfe?

Wenn Sie Hilfe mit Air King AKLC701 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ventilator Air King

Bedienungsanleitung Ventilator

Neueste Bedienungsanleitung für -Kategorien-