Air King AK965L Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Air King AK965L (12 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/12
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
965 Rev. H 11-18 1 of 12
Exhaust Fan with Heater
Models: AK-965L
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this heater only as described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock, or injury to persons.
b) Operate heater only when grille is installed.
c) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
d) Do not operate any heater after it malfunctions. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
e) Do not use outdoors.
f) Do not insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause and electric shock or fire, or damage the heater.
g) To prevent a possible fire, do not block air intakes or exhaust in any manner.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) For supply connections, use wires suitable for at least 75° C (167° F).
c) Use copper wire only.
d) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
f) A heater has hot and arcing or sparking parts inside. Do not use in areas where
gasoline, paint, or flammable vapors or liquids are used or stored.
g) Ducted fans must always be vented to the outdoors.
h) This unit must be grounded.
i) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
j) This heater is hot when in use. To avoid burns, do not let bare skin touch hot
surfaces.
k) Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
IMPORTANT INSTRUCTIONS: Read all instructions before installing or using
exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR
MOUNT IN A SHOWER STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THIS UNIT IS DESIGNED AND TESTED TO
BE A SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A
SWITCH. IT IS NOT INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT
AND CONTROLLED BY A THERMOSTAT.
Motor is thermally protected.
Electrical Ratings: AK965L - 120V, 60Hz., 15.65A
AKF965 - 120V, 60Hz., 15.20A
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: TO REDUCE THE RISK OF FIRE, DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THE HEATER.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill with Light Lens
4 - Mounting Rails
2 - 2 Function Switches
1 - Quad Wall Plate
1 - Instruction/Safety Sheet
2. Remove the two machine screws holding the light reflector in place. Keep the reflector
and screws in the carton until needed so they do not get damaged or lost (Figure 1).
3. Remove the wire compartment cover by loosening the two screws holding the cover in
place (Figure 2).
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A
SHOWER STALL ENCLOSURE.
4. Choose the location for your unit. To ensure the best air and sound performance, it
is recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be used.
Larger duct sizes will reduce noise and airflow
restrictions. This fan will require at least 7" of clearance
in the ceiling, and will mount through drywall up to 3/4"
thick. The fan can be mounted directly to the joist using
the mounting tabs on the side of the housing or between
16" on center joists using the 4 provided mounting rails.
5. Remove the electrical knockouts using a straight-blade
screw driver .(Figure 3)
SECTION 2
New Construction
1. Mounting Rail Installation: Install the rails on the housing and position the housing next
to the joist. Line up housing so it will be flush with the finished ceiling. Secure the ends
of the rails with screws or nails (not included) to the joists and slide housing into final
position (Figure 4).
www.airkinglimited.com
965 Rev. H 11-18 2 of 12
1a. Mounting Tab Installation: Line up housing so that it will be flush with the finished
ceiling. Position the fan so that the tabs rest flat against the joist and secure with screws
or nails (not provided) to ensure proper installation (Figure 5).
SECTION 3
Existing Construction
1. Mounting Rail Installation: Set housing in position between the joist and trace an outline
onto the ceiling material . Set housing aside and cut opening, being careful not (Figure 6)
to cut or damage any electrical or other hidden utilities. Install the rails on the housing and
position the housing in the previously cut hole so that it is flush with the finished ceiling.
Secure the ends of the rails to the joists with screws or nails (not provided) to ensure proper
installation (Figure 4).
1a. Mounting Tab Installation: Position housing against the joist and trace an outline of the
housing onto the ceiling material . Set housing aside and cut opening, being (Figure 7)
careful not to cut or damage any electrical or other hidden utilities. Place housing next to
the joist and insure that it is flush with the finished ceiling. Secure with screws or nails (not
provided) to the joists (Figure 5).
Figure 4
Housing
Joist
Mounting Rails
Figure 6
Screws
Figure 1
Screws
Figure 2
Wire
Compartment
Cover
Figure 3
Figure 5
Figure 7
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
1. Remove any tape that might be holding the damper in place. Connect the ducting to the
fan’s duct collar and secure in place using tape or screw clamp. Always duct (Figure 8)
the fan to the outside through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: THIS UNIT MUST BE WIRED ON A SEPARATE 20
AMP CIRCUIT.
WARNING: USE APPROPRIATELY SIZED COPPER
CONDUCTORS ONLY RATED FOR AT LEAST 75°C.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Using wiring carrying the appropriate rating, run a dedicated line on a 20 amp service
from the main service panel to an approved wall junction box (not included). Once inside
the junction box, split the hot (black) wire from the home and connect one end to each
of the switches into the terminal marked “COMMON TERMINAL”. Connect the ground
(green or bare copper) wire from the home to the junction box. The neutral (white) wire
from the home is not connected to the switch or junction box, but will be run to the
unit’s wire compartment. Use approved methods for all connections.
2. Run wiring from wall switches carrying the appropriate rating. One neutral (white), one
ground (green or bare copper), and four hot (black, red, blue, yellow leads connected
to the switch, one for each function). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make
the connection to the fan’s receptacles.
3. Connect the white wire from the house to the four white wires from the fan. Connect
one hot (black) wire from the wall switch to the black wire from the fan (this is the fan
control). Connect second hot (red) wire from the wall switch to the red wire from the
fan (this is the heat control). Connect the third hot (blue) wire from the wall switch to
the blue wire from the fan (this is the main light control). Connect the fourth hot (yellow)
wire from the wall switch to the yellow wire from the fan (this is the night light control).
Connect the ground wire from the house to the green wire from the fan . Use (Figure 9)
approved methods for all connections.
www.airkinglimited.com
965 Rev. H 11-18 3 of 12
4. Reinstall the wire compartment cover by sliding the tabs at the bottom of the cover into
the slots in the housing. Make sure all wires are tucked inside of the compartment and
are not being pinched or showing through. Reinstall the two screws removed in of Step 3
SECTION 1 (Figure 10) Preparing the Unit .
SECTION 6
Completing the Installation
1. Insert the plug from the heating unit into the receptacle marked“HEAT”, and the plug
from the fan into the receptacle marked “VENT”( (Figure 11).
2. Remove grill from carton and open light lens area by pushing in on the two tabs of the
light lens and pulling outward from lens. The lens will swing open on the connector bars.
DO NOT remove the lens from the grill (Figure 12).
3. Install light reflector into grill by lining up the posts on grill with the holes in light reflector
(Figure 13). Raise light reflector and grill up to housing and insert plug from light into
receptacle marked “LIGHT” (located on the side of the wire compartment) and insert plug
from night light into receptacle marked “NIGHT LIGHT”(Figure 11).
Figure 8
Figure 10
Slot
Light
Tab
Figure 11
Vent
Heater
Figure 9 Supply from house
Blue
Ground (Green
or Bare)
Fan
Green
Switch Black
Neutral (White)
By others
Switch
Black Red
Yellow
Figure 12
Connector
Bar
Tabs
Post
Hole
Post
Figure 13
Produktspezifikationen
Marke: | Air King |
Kategorie: | Heizung |
Modell: | AK965L |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Air King AK965L benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Heizung Air King
5 August 2024
2 August 2024
21 Juli 2024
17 Juli 2024
Bedienungsanleitung Heizung
- Heizung Aduro
- Heizung Sinbo
- Heizung AFK
- Heizung Infiniton
- Heizung Clatronic
- Heizung Domo
- Heizung Emerio
- Heizung Tristar
- Heizung Basetech
- Heizung Hama
- Heizung HP
- Heizung Nedis
- Heizung Philips
- Heizung SilverCrest
- Heizung Sunbeam
- Heizung Cotech
- Heizung Profile
- Heizung Quigg
- Heizung Adler
- Heizung Beper
- Heizung Bestron
- Heizung Camry
- Heizung Guzzanti
- Heizung Princess
- Heizung Trisa
- Heizung Bosch
- Heizung Parkside
- Heizung Vonroc
- Heizung AEG
- Heizung Ambiano
- Heizung Ardes
- Heizung Bauknecht
- Heizung Caso
- Heizung Concept
- Heizung Electrolux
- Heizung Fagor
- Heizung Gorenje
- Heizung Jata
- Heizung Klarstein
- Heizung Koenic
- Heizung Lervia
- Heizung Rommelsbacher
- Heizung Solis
- Heizung Teesa
- Heizung Unold
- Heizung Bomann
- Heizung Essentiel B
- Heizung H.Koenig
- Heizung Hendi
- Heizung Korona
- Heizung Melissa
- Heizung OK
- Heizung Russell Hobbs
- Heizung Steba
- Heizung Taurus
- Heizung Tefal
- Heizung Vox
- Heizung Velleman
- Heizung Powerfix
- Heizung Maginon
- Heizung Beurer
- Heizung Cresta
- Heizung Day
- Heizung ECG
- Heizung EMOS
- Heizung König
- Heizung Mesko
- Heizung Telefunken
- Heizung Thomson
- Heizung Black And Decker
- Heizung FERM
- Heizung Ryobi
- Heizung Trotec
- Heizung Mestic
- Heizung BEKO
- Heizung Blaupunkt
- Heizung Boretti
- Heizung Cuisinart
- Heizung Eldom
- Heizung Eta
- Heizung Heinner
- Heizung Hema
- Heizung Koenig
- Heizung Maestro
- Heizung Mio Star
- Heizung Prime3
- Heizung Primo
- Heizung Solac
- Heizung Wilfa
- Heizung Dometic
- Heizung Eureka
- Heizung Alpina
- Heizung Atlantic
- Heizung Candy
- Heizung DeWalt
- Heizung Corberó
- Heizung Einhell
- Heizung Bartscher
- Heizung Lynx
- Heizung Midea
- Heizung NABO
- Heizung Otsein-Hoover
- Heizung Svan
- Heizung Zanussi
- Heizung King
- Heizung Pelgrim
- Heizung Philco
- Heizung FlinQ
- Heizung Eurom
- Heizung Xiaomi
- Heizung Elro
- Heizung Olympia
- Heizung Hyundai
- Heizung Orava
- Heizung Orion
- Heizung Livoo
- Heizung Stanley
- Heizung DCG
- Heizung Easy Home
- Heizung Tectro
- Heizung Crane
- Heizung Atika
- Heizung Güde
- Heizung Perel
- Heizung Scheppach
- Heizung Bimar
- Heizung Stadler Form
- Heizung Rowenta
- Heizung Sencor
- Heizung DeLonghi
- Heizung Piazzetta
- Heizung Vasco
- Heizung Hartig And Helling
- Heizung Reer
- Heizung Maxwell
- Heizung Ariete
- Heizung Fakir
- Heizung Kalorik
- Heizung OneConcept
- Heizung Optimum
- Heizung Rotel
- Heizung Scarlett
- Heizung Superior
- Heizung Ufesa
- Heizung Eberspacher
- Heizung AccuLux
- Heizung Anslut
- Heizung Fenix
- Heizung Calor
- Heizung Cecotec
- Heizung Westfalia
- Heizung Zephir
- Heizung Vaillant
- Heizung Termozeta
- Heizung Qlima
- Heizung Dyson
- Heizung Bionaire
- Heizung Duracraft
- Heizung Duux
- Heizung Haverland
- Heizung Honeywell
- Heizung Remko
- Heizung Suntec
- Heizung Zibro
- Heizung Junkers
- Heizung Dedra
- Heizung Carson
- Heizung Zehnder
- Heizung Livington
- Heizung MSW
- Heizung Maxxmee
- Heizung Broan
- Heizung Ecron
- Heizung MPM
- Heizung Thermex
- Heizung Krüger
- Heizung ROWI
- Heizung Imetec
- Heizung Logik
- Heizung Team
- Heizung Fluval
- Heizung SuperFish
- Heizung Burley
- Heizung Remeha
- Heizung Stiebel Eltron
- Heizung Truma
- Heizung Brandson
- Heizung Toolland
- Heizung JML
- Heizung Heller
- Heizung Proline
- Heizung Delta
- Heizung Dimplex
- Heizung Heidenfeld
- Heizung Sonnenkönig
- Heizung Eurolite
- Heizung Hayward
- Heizung Noirot
- Heizung Gre
- Heizung Mora
- Heizung Milwaukee
- Heizung Aktobis
- Heizung Heylo
- Heizung Toyotomi
- Heizung CasaFan
- Heizung Baxi
- Heizung Tesy
- Heizung Tepro
- Heizung Vivax
- Heizung EWT
- Heizung Bestway
- Heizung Zelmer
- Heizung Mesa Living
- Heizung Kogan
- Heizung Royal Sovereign
- Heizung Innoliving
- Heizung Conceptronic
- Heizung United
- Heizung Argo
- Heizung Casaya
- Heizung HQ
- Heizung Vasner
- Heizung Master
- Heizung Dovre
- Heizung Invicta
- Heizung Enders
- Heizung SPC
- Heizung Alpatec
- Heizung Gutfels
- Heizung Olimpia Splendid
- Heizung SereneLife
- Heizung Sygonix
- Heizung Vitek
- Heizung AKO
- Heizung Longvie
- Heizung SHX
- Heizung Danby
- Heizung Sogo
- Heizung Eberle
- Heizung Alde
- Heizung Danfoss
- Heizung Fantini Cosmi
- Heizung Kent
- Heizung Mellerware
- Heizung Evolar
- Heizung EasyMaxx
- Heizung La Nordica
- Heizung Eden
- Heizung Real Flame
- Heizung Hark
- Heizung Ferroli
- Heizung Zibro Kamin
- Heizung Blumfeldt
- Heizung Signature
- Heizung Wamsler
- Heizung Trumatic
- Heizung Starlyf
- Heizung Sun Joe
- Heizung Noveen
- Heizung Swan
- Heizung Soler & Palau
- Heizung Mill
- Heizung Harvia
- Heizung Orbegozo
- Heizung Napoleon
- Heizung Dantherm
- Heizung Vemer
- Heizung Izzy
- Heizung CaterChef
- Heizung Jøtul
- Heizung Haas+Sohn
- Heizung Magma
- Heizung Defy
- Heizung DIO
- Heizung Duro Pro
- Heizung Duronic
- Heizung Ecoteck
- Heizung Emga
- Heizung Etherma
- Heizung Extraflame
- Heizung Fuave
- Heizung Global
- Heizung Grandhall
- Heizung Haceka
- Heizung Handson
- Heizung Heatstrip
- Heizung Jaga
- Heizung Jocel
- Heizung Just Fire
- Heizung Justus
- Heizung Kago
- Heizung Kambrook
- Heizung Kemper
- Heizung Kenmore
- Heizung Kompernass
- Heizung Lavorwash
- Heizung Myson
- Heizung Nefit
- Heizung Nefit-Bosch
- Heizung Nestor Martin
- Heizung Nobo
- Heizung Nordic Fire
- Heizung Plieger
- Heizung Prem-i-air
- Heizung Solamagic
- Heizung SPT
- Heizung SunRed
- Heizung Supra
- Heizung Thermor
- Heizung Grunkel
- Heizung Unical
- Heizung Uniprodo
- Heizung Vornado
- Heizung Waldbeck
- Heizung Wallas
- Heizung Wanders
- Heizung Webasto
- Heizung Zodiac
- Heizung Zymbo
- Heizung WAGAN
- Heizung WestBend
- Heizung AstralPool
- Heizung Argoclima
- Heizung Lasko
- Heizung Hatco
- Heizung Cadel
- Heizung Barbecook
- Heizung Dri Eaz
- Heizung Kunft
- Heizung Becken
- Heizung Nevir
- Heizung Rinnai
- Heizung Blaze
- Heizung Masport
- Heizung Hubbell
- Heizung Escea
- Heizung Ravanson
- Heizung Pacific Energy
- Heizung XPower
- Heizung Lenoxx
- Heizung Neo
- Heizung Jindara
- Heizung NewAir
- Heizung Flama
- Heizung AENO
- Heizung Brivis
- Heizung Chauvet
- Heizung Malmbergs
- Heizung Creda
- Heizung Nectre
- Heizung IXL
- Heizung JANDY
- Heizung Martec
- Heizung Monzana
- Heizung Ionmax
- Heizung Jarden
- Heizung Kaden
- Heizung Neopower
- Heizung Regency
- Heizung Braemar
- Heizung HeatStar
- Heizung PAX
- Heizung GoldAir
- Heizung Arnold Rak
- Heizung Guardian
- Heizung Stenda
- Heizung Ouellet
- Heizung HyCell
- Heizung Gasmate
- Heizung Bromic
- Heizung Rheem
- Heizung Hcalory
- Heizung Clean Air Optima
- Heizung Mr. Heater
- Heizung Haeger
- Heizung Yellow Garden Line
- Heizung Scandia
- Heizung Pureheat
- Heizung Fiap
- Heizung NEO Tools
- Heizung Mirpol
- Heizung Sunheat
- Heizung Gossmann
- Heizung Aerian
- Heizung DCS
- Heizung Quadra-Fire
- Heizung Everdure
- Heizung Blue Rhino
- Heizung Mission Air
- Heizung Create
- Heizung VIESTA
- Heizung Big Ass Fans
- Heizung Brentwood
- Heizung Omega Altise
- Heizung Airo
- Heizung Hortus
- Heizung Radialight
- Heizung TURBRO
- Heizung Ausclimate
- Heizung Thermotec
- Heizung Brixton
- Heizung Euromac
- Heizung Brink
- Heizung TAIDEN
- Heizung Veito
- Heizung Tecno Air System
- Heizung Adax
- Heizung Bromic Heating
- Heizung BeF Home
- Heizung True North
- Heizung Apricus
- Heizung Heatsome
- Heizung Invroheat
- Heizung Wulfe
- Heizung Herschel
- Heizung Arlec
- Heizung EvoHeat
- Heizung Contura
- Heizung Alkari
- Heizung Fire Sense
- Heizung InfraNomic
- Heizung Heat Storm
- Heizung Excelair
- Heizung Heatscope
- Heizung LifeSmart
- Heizung Heat1
- Heizung Kemlan
- Heizung Perfect Aire
- Heizung AustWood
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024