Adastra UA90 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Adastra UA90 (8 Seiten) in der Kategorie Empfänger. Dieser Bedienungsanleitung war für 21 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
UA-series
Compact 100V mixer-amplifiers
Item ref: UA 953.183 30 UK
UA 953.186 60 UK
UA 953.189UK 90
User Manual
Version 1.2
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warran ty
UA UA , UA User Manual 30, 60 90
Introduction
Thank you for choosing an Adastra UA-series mixer-amplifier as part of your public address system.
This unit is designed to offer high quality, dependable service for mobile and installed systems.
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating applianc es
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, water ingress or other damage, consult qualified service personnel
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or electric shock, do not expose any components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the cas refer all servicing to qualified service personnel. e
Safety
Check for correct mains voltage and condition of IEC lead before connecting to power outlet
Use double insulated speaker wire with adequate current rating for 100V speaker connections
Only use 1 type of output i.e. do not mix or combine these outputs on a single zone 8Ω or 100V –
Do not connect 8Ω speakers to the 100V terminal or 100V speakers to the 8Ω terminal
Do not allow any foreign objects to enter the case or through the ventilation grilles
Placement
Keep out of direct sunlight and away from heat sources
Keep away from damp or dusty environments
For rack-mounting, use the supplied accessories and ensure adequate support
Ensure adequate airflow and do not cover cooling vents at the front and rear of the amplifier
Ensure adequate access to controls and connections
Cleaning
Use a soft cloth with a neutral detergent to clean the casing as required
Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
Do not use strong solvents for cleaning the unit
UA UA , UA User Manual 30, 60 90
Rack mounting
The UA series amplifiers can be mounted into a 19 rack cabinet using the supplied rack accessories.
As shown below, the 2 joining brackets link a pair of UM series amplifiers together to form a full-width 1U
rack-mount pair. One rack ear can be mounted at each end for xing to the rack strip. fi
Wall or under counter mounting
The rack mounting accessories can al be attached so that the so
amplifier can be mounted against a wall or under a counter or
work surface. To do this, mount the rack ears with the tabs
aligned with the top of the housing to provide mounting holes
to screw the amplifier to the underside of a work surface or
against a wall with the controls visible vertically.
Front panel
Rear panel
1.
CH1 volume control
6.
MASTER volume control
2.
CH2 volume control
7.
CH1 XLR/Jack input
3.
CH3 volume control
8.
3.5mm stereo AUX input
4.
LINE 4 volume control
9.
Power and Audio output indicators
5.
AUX volume control
10.
IEC power inlet and fuse holder
11.
Power on/off switch
12.
100V and 8 speaker output terminals
13.
L 4 RCA input INE
14.
CH3 6.3mm and screw terminals input
15.
CH2 6.3mm and screw terminals input
16.
CH1 Phantom-Mic/Line-Vox DIP switches
17.
LINE OUT RCA outpu t
18.
CH2/CH3 Mic/Line DIP switches
19.
CH1 screw terminals input
20.
24V MUTE terminals


Produktspezifikationen

Marke: Adastra
Kategorie: Empfänger
Modell: UA90

Brauchst du Hilfe?

Wenn Sie Hilfe mit Adastra UA90 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Empfänger Adastra

Bedienungsanleitung Empfänger

Neueste Bedienungsanleitung für -Kategorien-