RM4 06
Rackmount 6-zone Mixer-Amplifier
Item ref: 160 953. UK
User Manual
Version 1.1
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
953.160 User Manual UK
Introduction
Thank you for choosing the Adastra RM4 rackmount 6-zone mixer-amplifier as part of your public address 06
system. This unit is designed to offer high quality, dependable service for mobile and installed systems.
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, water ingress or other damage, consult qualified service personnel
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or electric shock, do not expose any components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
• Check for correct mains voltage and condition of IEC lead before connecting to power outlet
• Use double insulated speaker wire with adequate current rating for 100V speaker connections
• Only use 1 type of output per zone do not mix or combine these outputs on a single zone – i.e. 4Ω, 8Ω or 100V –
• Do not connect speakers to the s 4Ω or 8Ω speakers to the 100V terminal or 100V 4Ω or 8Ω terminal
• Do not allow any foreign objects to enter the case or through the ventilation grilles
Placement
• For rack-mounting, ensure adequate support for the weight of the amplifier
• Ensure adequate air-flow and do not cover cooling vents at the sides of the amplifier
• Ensure adequate access to controls and connections
Cleani ng
• Use a soft cloth with a neutral detergent to clean the casing as required
• Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
• Do not use strong solvents for cleaning the unit
953.160 User Manual UK
Front panel
Rear panel
1.
Media player
19.
USB port
2.
Mic/Line 1 level control
20.
Media playback zone assign buttons
3.
Mic/Line 2 level control
21.
Mic/Line 1 zone assign buttons
4.
Mic/Line 3 level control
22.
Mic/Line 2 zone assign buttons
5.
Auxiliary line input level control
23.
Mic/Line 3 zone assign buttons
6.
Zone 1 output level control
24.
Auxiliary line input zone assign buttons
7.
Zone 1 monitor send button
25.
Zone 4 output level control
8.
Zone 1 output LED indicators
26.
Zone 4 monitor send button
9.
Zone 2 output level control
27.
Zone 4 output LED indicators
10.
Zone 2 monitor send button
28.
Zone 5 output level control
11.
Zone 2 output LED indicators
29.
Zone 5 monitor send button
12.
Zone 3 output level control
30.
Zone 5 output LED indicators
13.
Zone 3 monitor send button
31.
Zone 6 output level control
14.
Zone 3 output LED indicators
32.
Zone 6 monitor send button
15.
Chime button
33.
Zone 6 output LED indicators
16.
Chime output level control
34.
Monitor headphones output
17.
Power indicator
35.
Monitor output level control
18.
SD card slot
36.
Power on/off switch
37.
Voltage selector
47.
Mains power inlet (IEC) and fuse holder
38.
Zone 1 speaker output terminals
48.
Zone 2 speaker output terminals
39.
Zone 3 speaker output terminals
49.
Zone 4 speaker output terminals
40.
Zone 5 speaker output terminals
50.
Zone 6 speaker output terminals
41.
Zones 1-6 line level outputs (RCA)
51.
Monitor line level output (2 x RCA)
42.
Channel 4 Auxiliary input (2 x RCA)
52.
Channel 3 DIP switches (mic/line + phantom)
43.
Chann 3 Mic/Line input (XLR/jack) el
53.
Channel 2 DIP switches (mic/line + phantom)
44.
Channel 2 Mic/Line input (XLR/jack)
54.
Channel 1 DIP switches (mic/line + phantom)
45
Channel 1 Mic/Line input (XLR/jack)
55.
Channel 1 priority switch
46.
Antenna connection
56.
24V emergency mute contacts


Produktspezifikationen

Marke: Adastra
Kategorie: Empfänger
Modell: RM406

Brauchst du Hilfe?

Wenn Sie Hilfe mit Adastra RM406 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Empfänger Adastra

Bedienungsanleitung Empfänger

Neueste Bedienungsanleitung für -Kategorien-