Zoeller M267 Bedienungsanleitung
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Zoeller M267 (8 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war fĂĽr 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/8
1
© Copyright 2017 Zoeller
® Co. All rights reserved.
SECTION: 5.10.300
FM0600
1217
Supersedes
0916
SINGLE PHASE SYSTEM
GENERAL
Pump motor shall be hermetically sealed, submersible type
operating in a high quality dielectric oil for cooling the windings
and for lubrication of the motor bearings and ceramic-carbon shaft
seal. Single phase motor shall have internal automatic resetting,
thermal overload protection. Construction shall be of ______ cast
iron with 100% baked-on powder coated epoxy îšżnish for corrosion
resistance and longer casting durability (or ______ cast bronze).
All fasteners and external metal parts shall be of stainless steel.
Impeller shall be of vortex non-clog design. (Addition noted below.)
Check applicable series:
______ 264 (.4 HP) model pump shall have a P.S.C. motor. Cast
iron switch case, motor housing and pump housing with
plastic impeller and base.
______ 266 (1/2 HP) model pump shall have a split phase motor
with current sensing, starting relay enclosed in switch
housing. Cast iron switch case, motor housing and pump
housing with plastic impeller and base.
______ 267 (1/2 HP) model pump shall have a split phase motor with
current sensing, starting relay enclosed in switch housing.
______ 270 (1 HP) cast iron series pump shall have a permanent
split cpacitor motor with capacitor enclosed in the upper
housing attached to the pump. The impeller shall be cast
bronze. Motor housing shall be cast iron.
______ 4270 (1 HP) cast iron series pump with double carbon/
ceramic shaft seals shall have a permanent split capactior
motor with capacitor enclosed in the upper housing attached
to the pump. The impeller shall be cast bronze. Motor
housing shall be cast iron. The lower seal cavity shall be
oil îšżlled.
SPECIFICATIONS
SEWAGE/SUMP SIMPLEX SYSTEM
ZOELLER COMPANY SUBMERSIBLE OR DEWATERING PUMPS
CAST IRON SERIES
SIMPLEX SYSTEM
Furnish a Zoeller nonautomatic submersible pump(s), Model ______ Single Seal or Model ______ Double Seal, ______ a simplex
control panel or ______ a combination starter. Pumps shall have a capacity of ______ GPM against a Total Dynamic Head of ______
feet. Motor Specication: ______ Voltage, ______ Cycles, ______ Phase, ______ HP. Discharge to be ______ 2” NPT or ______ 3”
NPT or ______ 4” ange (404/4404, 405/4405). Cord length to be ______ feet. Pump shall be mounted on rail system with NPT
______ or ange ______ discharge. Pumps will pass ______ 2” solids (264, 266, 267, 270/4270, 282/4282, 284/4284, 292/4292,
293/4293, 294/4294, 295/4295) or ______ 3” solids (404/4404, 405/4405). Pumps shall be ______ UL Listed, ______ CSA approved,
______ SSPMA certiîšżed, ______ State of Wisc. approved, ______ other (Specify ____________________________________).
______ 282 (1/2 HP) cast iron series pump shall have a permanent
split capacitor motor with run capacitor enclosed in the
upper housing attached to the pump. Impeller and motor
housing shall be cast iron. The motor housing shall be
îšżnned for extra cooling capability.
______ 284 (1 HP) cast iron series pump shall have a permanent
split capacitor motor with run capacitor and, on automatic
units, a magnetic contactor enclosed in the upper housing
attached to the pump. Impeller and motor housing shall
be cast iron. The motor housing shall be îšżnned for extra
cooling capability.
______ 4282 (1/2 HP) ______4284 (1 HP) cast iron series pump with
double carbon/ceramic shaft seals shall have a permanent
split capacitor motor with run capacitor enclosed in the
upper housing attached to the pump. Impeller and motor
housing shall be îšżnned for extra cooling capability. The
lower seal cavity shall be oil-îšżlled.
______ 292 (1/2 HP) _____293 (1 HP) _____294 (1/2 HP) _____295
(2 HP) cast iron series pump shall a permanent split capacitor
motor with capacitor and, on automatic units, a magnetic
contactor enclosed in the upper housing attached to he
pump. The impeller shall be cast iron. Motor housing shall
be cast iron and îšżnned for extra cooling capability.
______ 4292 (1 HP) _____4293 (1 HP) _____4294 (1-1/2
HP) _____4295 (2 HP) cast iron series pump with double
carbon/ceramic shaft seals shall have a permanent split
capacitor motor enclosed in the upper housing attached to
the pump. The impeller shall be cast iron. Motor housing
shall be cast iron and îšżnned for extra cooling capability.
The lower seal cavity shall be oil îšżlled.
SINGLE SEAL 264 266 267 270 282 284 292 293 294 295 404 405
DOUBLE SEAL 4270 4282 4284 4292 4293 4294 4295 4404 4405
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
Visit our web site:
zoellerpumps.com
2
© Copyright 2017 Zoeller
® Co. All rights reserved.
______ 404 (2 HP) _____405 (3 HP) cast iron series pump shall
have a permanent split capacitor motor with capacitor
enclosed in the upper housing attached to the pump.
Impeller and motor housing shall be cast iron. The motor
housing shall be îšżnned for extra cooling capability.
______ 4404 (2 HP) _____405 (3 HP) cast iron series pump with
double carbon/ceramic shaft seals shall have a permanent
split capacitor motor with capacitor enclosed in the upper
housing attached to the pump. The impeller and motor
housing shall be cast iron. The motor housing shall be
îšżnned for extra cooling capability. The lower seal cavity
shall be oil îšżlled.
AUTOMATIC CONTROL - INTEGRAL FLOAT TYPE
Single phase pump shall have an integral mechanical oat switch,
which shall require no adjustment, nor require additional equipment
for operation.
AUTOMATIC CONTROL PIGGYBACK
VARIABLE LEVEL FLOAT SWITCH
A Zoeller _____ Piggyback Variable Level Float Switch with a
îšżfteen (15) foot SJOWA cord and molded plug shall be furnished
to control a nonautomatic pump. Control shall be constructed of
durable plastic and be omnidirectional. Control shall be fastened
to discharge pipe with plastic tie mounting strap and shall require
no extra wiring. (Addition Noted Below.)
Check applicable control:
_____ 10-0032 (115 V/Max. 15 Amps) or _____ 10-0033
(230 V/Max. 15 Amps), ____ 10-0034 (115 V/Max. 13 Amps)
or _____ 10-0035 (230 V/Max. 13 Amps) (For use on 115 V
or 230 V, 1 Phase, nonautomatic Zoeller pump.) Designed
for automatic pump operation with the appropriate voltage
and horsepower, single phase, Zoeller pump.
_____ 10-0229 (115 V/Max. 1 HP) or _____ 10-0230 (230 V/Max.
2 HP) (For use on 115 V or 230 V, 1 Phase, nonautomatic
Zoeller pump.) Double oat system shall have an adjustable
pumping range. Pumping range shall be a minimum of
one (1) inch to a maximum of forty-eight (48) inches.
SIMPLEX CONTROL PANEL
A Zoeller __________Simplex Control Panel shall be furnished
to control a nonautomatic pump. The panel shall have a NEMA
4X enclosure, pump run indicator light, high water alarm, selector
switches, oat switches, and UL label.
_____ 10-0123 120 V/1 Ph and 15 max. amps
_____ 10-0124 208-230 V/1 Ph and 15 max. amps
_____ 10-0323 115-208-230 V/1 Ph and 15 max. amps
_____ 10-0125 115-208-230 V/1 Ph and 20 max. amps
THREE PHASE SYSTEM
(FOR USE WITH 3 PHASE PUMPS)
GENERAL
Pump motor shall be hermetically sealed, submersible type,
operating in a high quality dielectric oil for cooling the windings
and for lubrication of the motor bearings and ceramic-carbon shaft
seal. Pump motor shall have external magnetic contactor and
overload protection. All fasteners and external metal parts shall
be of stainless steel. Impeller shall be of vortex non-clog design.
(Addition noted below).
_____ 266 (1/2 HP) _____ 267 (1/2 HP) series shall have a 4-pole
squirrel cage induction motor.
_____ 282 (1/2 HP) _____ 284 (1 HP) series shall have a 4-pole
squirrel cage induction motor. The motor housing shall be
îšżnned for extra cooling capability.
_____ 4282 (1/2 HP) _____ 4284 (1 HP) cast iron series pump
with double carbon/ceramic shaft seals shall have a 4-pole
squirrel cage induction motor. Impeller and motor housing
shall be cast iron. The motor housing shall be îšżnned for
extra cooling capability. The lower seal cavity shall be oil-
îšżlled.
_____ 292 (1/2 HP) _____ 293 (1 HP) _____294 (1-1/2 HP)
______295 (2 HP) series shall have 2-pole squirrel cage
induction motor. Impeller shall be cast iron. The motor
housing shall be îšżnned for extra cooling capability.
_____ 4292 (1/2 HP) _____4293 (1 HP) _____4294 (1-1/2 HP)
______4295 (2 HP) cast iron series pump with double
carbon/ceramic shaft seals shall have 2-pole squirrel cage
induction motor. The impeller shall be cast iron. Motor
housing shall be cast iron and îšżnned for extra cooling
capability. The lower seal cavity shall be oil-îšżlled.
_____ 404 (2 HP) _____405 (3 HP) series shall have 4-pole
squirrel cage induction motor. Impeller and motor housing
shall be cast iron. The motor housing shall be îšżnned for
extra cooling capability.
_____ 4404 (2 HP) _____4405 (3 HP) cast iron series pump with
double carbon/ceramic shaft seals shall have 4-pole squirrel
cage induction motor. The impeller and motor housing shall
be cast iron. The motor housing shall be îšżnned for extra
cooling capability. The lower seal cavity shall be oil-îšżlled.
SIMPLEX CONTROL PANEL
A Zoeller ______ Simplex Control Panel with three control switches
shall be furnished to control a nonautomatic pump. The panel shall
have a NEMA 4X enclosure, pump run indicator light, high water
alarm, selector switches, and a UL label. Panel will be sized for
Zoeller Model ______, ______ Volt, ______ Cycle, ______ Phase,
______ HP, ______ FLA pump.
CONTROL SWITCHES
A Zoeller Float Switch shall be furnished to operate control circuit.
Float shall be omnidirectional and include a 20’ SJOWA cord and
plastic tie mounting strap.
3
© Copyright 2017 Zoeller
® Co. All rights reserved.
ACCESSORIES/MISCELLANEOUS
UNICHECK
_____ 30-0021 (Clamp Union Valve) (2 inch) full ow check
valve, rated at 4.3 PSI (10 feet TDH) at 130 °F shall be
furnished to îšżt 2 inch ABS, PVC, CPVC, steel or copper
piping. Unicheck shall have valve body and seat of PVC
plastic and shall be assembled with thru bolts. Gasket
and apper shall be neoprene with brass backing plates.
Unicheck shall include two (2) neoprene unions and four
(4) stainless steel clamps and fasteners.
_____ 30-0151 (Compression Union Valve) 2 inch IPS full ow
check valve. Rated at 4.3 PSI (10 feet TDH) at 130 °F
shall be furnished to îšżt 2 inch ABS, PVC, CPVC, steel or
copper piping. Valve body and seat shall be of cast iron.
Gasket and apper shall be neoprene with brass backing
plates and stainless steel rivet. Unicheck shall include two
(2) neoprene unions and four (4) stainless steel clamps
and fasteners.
_____ 30-0020 (2 inch) or _____30-0030 (3 inch) IPS full ow
compression union check valve shall be furnished. Unicheck
body and compression end îšżttings shall be constructed of
PVC. Flapper and end seals shall be Buna-N. Valve shall
include no metallic parts. Pressure rated at 4.3 PSI (10
feet THD) at 130 °F.
_____ 30-0152 (2 inch) or _____30-0160 (3 inch) cast iron full
ow check valve with female N.P.T. Rated at 50 PSI (115
feet TDH) at 130 °F. Neoprene polyester reinforced apper
with cast iron and brass backing plates and stainless steel
fastener.
_____ 6030-0203 (4 inch) anged cast iron check valve. Rated at
200 PSI pressure. Ductile iron body, and cover with Buna
-N in reinfunced disc.
_____ Tri-check®/Combo, 30-0101 or 30-0103.
OPTIONAL ALARM SYSTEM
An audible high water alarm system shall include a Zoeller
_____ 10-4012 (115 V / 1 Ph) APak® complete with tethered oat
and NEMA 1 plastic enclosure (cord and plug). Solid state
and warning light and horn, which can be manually turned
off. cCSAus Certiîšżed on complete alarm system.
_____ 10-0126 (115 V / 1 Ph) High level Alarm complete with NEMA
4X enclosure, alarm bell, Alarm light, Silence switch, and
sensor oat switch with 15’ cord. Entire unit is UL Listed
and CSA Certiîšżed.
_____ 10-0623 (115 V / 1 Ph) High Level Alarm rated for Indoor/
Outdoor use per UL 864. The alarm will include an alarm
horn, alarm light, silence and test buttons, and a 15’ oat
switch.
_____ 10-0682 (115 V /1 Ph) deluxe high level alarm rated for
indoor/outdoor use per UL 864. The alarm will include an
alarm horn, alarm light, silence and test buttons, a 20’ oat
switch, 6’ power cord, and watertight connectors.
SUMP BASIN
A Zoeller IAPMO _____ polyethylene basin, .200 inch thick, .949
G/CC dense, or Zoeller _____ îšżberglass basin, 3/16 inch thick, .058
pounds/cubic feet dense, _____ inches inside diameter by _____
inches deep shall be furnished. The basin shall include _____ four
(4) inch cast iron caulk inlet hubs with anticorrosion coating. The
center-line of the hub(s) shall be located nine (9) inches from the
top of the basin. The basin shall also include a .115 inch thick steel
sump cover. An optional pump installation plate can be provided
on covers twenty-four (24) inches in diameter or larger. Optional
anti-otation ring can also be provided. Also included shall be a
neoprene seal for pump cord, neoprene seal for vent and discharge
ange, foam cover seal and plated steel fasteners. Cover shall
include a _____ inch vent and a _____ inch discharge ange with
mounting hardware.
PIPING & POWER WIRING
All piping shall be rigid and permanent in nature and shall be
furnished and installed by the contractor. A Unicheck shall be installed
in the discharge pipe. A 3/16 inch vent hole shall be drilled in the
discharge pipe below the check valve and pit cover to purge the
system of trapped air. Power wiring shall be supplied by electrical
contractor. Power wiring for pumping system and alarm system
shall be connected to separate circuits.
EXTRA DUTY
Where conditions require, specify extra duty for adverse conditions.
HIGH TEMPERATURE PUMPS
For applications up to 200 °F continuous operation, specify High
Temperature Zoeller Pump Co. models. See literature on High
Temperature pumps, FM2811, FM1923 and FM0807, for additional
information.
PUMP DISCONNECTS AND RAIL SYSTEMS
Where conditions, due to safety, health and the economy of
maintenance require pump disconnects or rail systems specify:
____ 39-0002, 2” Disconnect (Non-pump Supporting)
____ 39-0004, 2” NPT Rail System (Non-pump Supporting)
____ 39-0128, 2” x 2” Z-Rail Disconnect System, all Ductile Iron
Construction
____ 39-0129, 2” x 2” Z-Rail Disconnect System, Ductile Iron
Construction w/ SS Upper Rail Bracket
____ 39-0122, 3” x 3” Z-Rail Disconnect System, all Ductile Iron
Construction
____ 39-0123, 3” x 3” Z-Rail Disconnect System, Ductile Iron
Construction w/ SS Upper Rail Bracket
The Z-Rail® Disconnect System is a pump support assembly
consisting of a disconnect îšżtting, rail plate & guide and utilizes two
3/4” rail pipes that guide the pump into and out of the basin. The
assembly components are made of ductile iron with an optional 304
SS upper rail support bracket.Used in concrete, steel or îšżberglass
basins, it allows for the installation or removal of the pump from the
basin at ground level without entering the basin. The disconnect
îšżtting has a machined îšżt with an O-ring seal that holds up to 160
psi, being able to support pumps weighing up to 300 lbs. The 3/4”
rail pipes are provided by the installer, being either galvanized
steel or SS pipe.
____ 39-0094, 3” x 3” Flanged Rail System, connected horizontally,
powder coated cast iron and îšżtted with a SS support bracket.
2” schedule 40 rail pipes are provided by others.
____ 39-0016, 4” x 4” Flanged Rail System, connected horizontally,
powder coated cast iron and tted with SS rail brackets. 2”
schedule 40 rail pipes are provided by others.
Produktspezifikationen
Marke: | Zoeller |
Kategorie: | pomp |
Modell: | M267 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Zoeller M267 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Zoeller
24 August 2024
24 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp GĂĽde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp ZĂ©fal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung fĂĽr -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024