Zodiac Z900 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Zodiac Z900 (22 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war für 34 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/22
H0590800.A - 2017/05
More documents on:
www.zodiac-poolcare.com
Z900
Instruc ons for installa on and use - English
Heat pump
Transla on of the original instruc ons in french EN
1
EN
WARNINGS
• Failure to respect the warnings may cause serious damage to pool equipment or cause serious injury, even death.
• The appliance is intended to be used only for swimming pools and spas; it must not be used for any purpose other than that for
which it has been designed.
• It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) people who have
previously received the instruc ons for use. All persons not mee ng these criteria must not approach the appliance in order to
avoid exposure to dangerous elements.
• Keep the appliance out of the reach of children.
• The device must be installed by a qualifi ed technician according to the manufacturer’s instruc ons and in compliance with local
regula ons. The installer is responsible for installa on of the equipment and for compliance with na onal installa on regula ons.
Under no circumstances can the manufacturer be held liable in the event of failure to comply with applicable local standards.
• Incorrect installa on and/or use may cause serious damage to property or serious injuries (possibly resul ng in death).
• Any equipment, even carriage and packing paid, travels at the consignee's risk. The consignee should enter any reserva ons in
wri ng on the carrier’s delivery note, if there is any evidence of transport damage (and confi rm them by recorded delivery le er
to the carrier within 48 hours). In the event of a device containing coolant fl uid that has been pped over, issue your reserva ons
to the carrier in wri ng.
• If the appliance suff ers a malfunc on, do not try to repair it yourself; contact a qualifi ed technician.
• Refer to the warranty condi ons for details of the permi ed water balance values for opera ng the appliance.
• Elimina ng or shun ng one of the safety devices automa cally voids the warranty, as does the replacement of parts using parts
not manufactured by ourselves.
• Do not spray insec cide or any other chemical (infl ammable or non-infl ammable) in the direc on of the appliance, as this may
damage the body and cause a fi re.
• Heat pump, fi ltra on pump and fi lter appliances are compa ble with all types of water treatment.
• Do not touch the fan and/or moving parts or insert a rod or your fi ngers in the vicinity of the moving parts while the appliance is
in opera on. The moving parts may cause severe injury, including death.
• The electrical supply to the appliance must be protected by a dedicated 30 mA diff eren al residual current protec on device,
complying with the standards and regula ons in force in the country where it is installed.
• Do not use an extension cord to plug the appliance into; plug it directly into a proper wall socket or outlet.
• Before carrying out any opera ons, check that:
- The voltage indicated on the maker's plate of the appliance corresponds to the mains voltage,
- The power grid is adapted to the power requirements of the appliance, and is properly grounded.
- The plug (where applicable) is suitable for the socket.
• In the event of abnormal func on or the release of odours from the appliance, turn it of immediately, unplug it from its power
supply and contact a professional.
• Before any access to the appliance for any required service or maintenance, ensure that it is switched off and disconnected from
the power supply. In addi on to any other equipment connected to the appliance, and that the hea ng priority (where applicable)
is deac vated.
• Do not disconnect and reconnect the appliance to the power supply when in opera on.
• Do not pull on the power cord to disconnect it from the power supply.
• Do not a empt to carry out any service or maintenance with wet hands or while the appliance is wet.
• Clean the terminal board or the power supply socket before connec on.
• For any component or sub-assembly containing a ba ery: do not recharge or dismantle the ba ery, or throw it into a fi re. Do not
expose it to high temperatures or direct sunlight.
• In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.
• Do not immerse the appliance in water (with the excep on of cleaners) or mud.
• Do not discharge R410A or R407C fl uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered by the Kyoto
Protocol, with a Global Warming Poten al (GWP) = 2088 for R410A (Direc ve EC 842/2006).
• According to French decree No. , if the appliance has more than 5teq CO2 of refrigerant gas (refer to manufacturer 2015-1790
specifi ca ons), the cooling circuit must be checked for leakage at least once a year. This opera on must be carried out by a cer fi ed
cooling appliance specialist.
The heat pumps comply with Direc ve 2014/68/EU (PED) via Annex III, Module D1, and cer fi ed as such by the third-party,
independent No fi ed Body, ICIM No. 0425.
Addi onal considera ons in rela on to this Direc ve
Installa on and maintenance
The unit may not be installed close to combus ble materials, or the air duct inlet of an adjacent building .
With some devices, it is essen al to fi t protec on grids if the unit is installed in an area with uncontrolled access.
During installa on, troubleshoo ng and maintenance, pipes may not be used as steps: the pipe could break under the weight, spilling
refrigerant and possibly causing serious burns.
When servicing the appliance, the composi on and state of heat carrying fl uid must be checked, as well as the absence of any
refrigerant.
During the annual unit sealing test in accordance with applicable legisla on, the high and low pressure switches must be checked to
ensure that they are securely fastened to the coolant circuit and that they cut-off the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around cooling components.
Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi ng the temperature and pressure
sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high pressures with the
consequent risk of severe scalding.
Troubleshoo ng
All soldering work must be carried out by a someone qualifi ed to do so.
Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.
Leak detec on, pressure test:
- never use oxygen or dry air, risk of fi re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informa on plate,
- the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A) in the case the device is
equipped with the op onal pressure gauge.
The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1’’5/8. A cer fi cate as indicated in
§2.1 in compliance with standard NF EN 10204 will be requested from the supplier and fi led in the facility's technical documenta on.
Technical data rela ve to the safety requirements of the various applicable direc ves must be indicated on the informa on plate.
All this informa on must be recorded in the unit's installa on manual, which must be kept in the technical fi le of the unit: model,
code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturer’s address, refrigerant and weight,
electrical parameters, thermo-dynamic and acous c performances.
Recycling
This symbol means that your appliance should not be disposed of with other rubbish. It should be selec vely sorted so that it
can be re-used, recycled or transformed. If it contains any substances that may be harmful to the environment, these will be
disposed of or neutralised.
Contact your retailer for recycling informa on.
Produktspezifikationen
Marke: | Zodiac |
Kategorie: | Pumpe |
Modell: | Z900 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Zodiac Z900 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe Zodiac
21 Mai 2023
21 Mai 2023
21 Mai 2023
21 Mai 2023
Bedienungsanleitung Pumpe
- Pumpe Crivit
- Pumpe SilverCrest
- Pumpe SKS
- Pumpe Quigg
- Pumpe Makita
- Pumpe Parkside
- Pumpe Vonroc
- Pumpe Siemens
- Pumpe Powerfix
- Pumpe Trotec
- Pumpe Outwell
- Pumpe Einhell
- Pumpe Bartscher
- Pumpe Telestar
- Pumpe Tacklife
- Pumpe Ultimate Speed
- Pumpe Eheim
- Pumpe Eurom
- Pumpe Hyundai
- Pumpe Fuxtec
- Pumpe Metabo
- Pumpe Kärcher
- Pumpe Güde
- Pumpe Biltema
- Pumpe Fieldmann
- Pumpe Enermax
- Pumpe Michelin
- Pumpe Florabest
- Pumpe Germania
- Pumpe Zipper
- Pumpe EUFAB
- Pumpe Jabsco
- Pumpe Sanibroyeur
- Pumpe Batavia
- Pumpe Topeak
- Pumpe Hayward
- Pumpe Milwaukee
- Pumpe Toolcraft
- Pumpe Osram
- Pumpe Bestway
- Pumpe AL-KO
- Pumpe Gardena
- Pumpe Verto
- Pumpe Powerplus
- Pumpe Cannondale
- Pumpe Lezyne
- Pumpe Neptun
- Pumpe Sicce
- Pumpe Danfoss
- Pumpe Hozelock
- Pumpe Ozito
- Pumpe Ferroli
- Pumpe Nibe
- Pumpe Sun Joe
- Pumpe Fluke
- Pumpe Generac
- Pumpe Lavorwash
- Pumpe Oase
- Pumpe OKAY
- Pumpe Plantiflor
- Pumpe Velda
- Pumpe Waldbeck
- Pumpe AstralPool
- Pumpe T.I.P.
- Pumpe Heissner
- Pumpe DAB
- Pumpe Baracuda
- Pumpe Rule
- Pumpe JANDY
- Pumpe Park Tool
- Pumpe Lifan
- Pumpe Elpumps
- Pumpe For_Q
- Pumpe Simpson
- Pumpe Pontec
- Pumpe BluGarda
- Pumpe Grundfos
- Pumpe Superior Pump
- Pumpe Zoeller
- Pumpe SHURflo
- Pumpe Ergotools Pattfield
- Pumpe Ebara
- Pumpe Basement Watchdog
- Pumpe Madimack
- Pumpe Barwig
- Pumpe Wayne
- Pumpe SANDPIPER
- Pumpe Zehnder Pumpen
Neueste Bedienungsanleitung für -Kategorien-
26 Juni 2024
26 Juni 2024
26 Juni 2024
26 Juni 2024
25 Juni 2024
14 Juni 2024
4 Juni 2024
4 Juni 2024