Worcester GB162-100 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Worcester GB162-100 (12 Seiten) in der Kategorie Durchlauferhitzer und Boiler. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
UK/IE
User instructions
Wall hung gas-fired condensing boiler
Worcester Commercial Boiler Series
GB162-50/65/80/100
6 720 648 726-000.1TD
For central heating systems and indirect fed domestic hot water
6720813172 (2015/04)
preface
6720813172 (2015/04)2
preface
Please read these instructions carefully
These instructions are applicable to the Worcester, Bosch Group boiler
model stated on the front cover only.
These instructions apply in the UK/IE only and must be followed except
for any statutory obligation.
After installation please leave this User instruction Manual, Installation,
Commissioning and Servicing Instructions and completed Benchmark
Checklist with the user.
Dedicated to heating comfort
Thank you for purchasing a Worcester GB162 gas-fired condensing
boiler manufactured by Worcester, Bosch Group. The company prides
itself on manufacturing boilers to the strictest quality control standards
throughout every stage of production.
Worcester, Bosch group has led the field in innovative boiler design and
performance for over 50 years. This heritage means all our products are
of exceptional quality and proven reliability.
The Worcester commercial range in particular is extremely energy
efficient, offering you economical running costs and value for money.
There is also the reassurance of our no-nonsense 2 years parts and
labour guarantee.
Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . . 2
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Energy efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Overview of the BC10 basic controller . . . . . . . . . . . . . . . . . . . 4
5 Service Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6 Maintaining your Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7 Explanation of the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8 Operating the heating system . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8.1 Menu structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8.1.1 Normal Operation menu . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8.1.2 Manual Operation menu . . . . . . . . . . . . . . . . . . . . . . . . . . 6
9 Extreme Cold Weather . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
10 Display information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.1 Display readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.2 Display codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.2.1 Fault or Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10.3 Identifying and resetting faults . . . . . . . . . . . . . . . . . . . . 9
11 Tips on energy saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
12 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
13 Your Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 Key to symbols and safety instructions
1.1 Key to symbols
Warnings
Keywords indicate the seriousness of the hazard in terms of the
consequences of not following the safety instructions.
NOTICE indicates that material damage may occur.
CAUTION indicates that minor to medium injury may occur.
WARNING indicates that serious injury may occur.
DANGER indicates possible risk to life.
Important information
Additional symbols
1.2 safety precautions
INTENDED USE
This boiler is only to be used to heat heating system water and for the
domestic hot water (DHW) supply e. g. in residential and light
commercial properties. It can also be integrated into a cascade system
(where several boilers are interconnected).
The boiler has been factory-fitted with the BC10 basic controller and the
“Universal Burner Automat 3” (UBA 3).
Warnings in this document are framed and identified by
a warning triangle which is printed on a grey
background.
Electrical hazards are identified by a lightning symbol
surrounded by a warning triangle.
Important information in cases where there is no risk of
personal injury or material losses is identified by the
symbol shown on the left. It is bordered by horizontal
lines above and below the text.
Symbol Meaning
a step in an action sequence
a reference to a related part in the document or to other
related documents
a list entry
a list entry (second level)
Table 1
General Information
6720813172 (2015/04) 3
If you smell gas!
Call the National Gas Emergency Service on:
0800 111 999
Extinguish any naked flames
Do not smoke or strike matches
Do not turn electrical switches on or off
Open doors and windows
Keep people away from the affected area
Turn off the gas control valve at the meter
Boiler Operation
This boiler must only be operated by a responsible adult who has been
instructed in, understands and is aware of the boiler's operating
conditions and effects.
Combustible and Corrosive Materials
Chemically aggressive substances can corrode the boiler and invalidate
any warranty.
Do not store or use any combustible materials (paper, thinners,
paints etc.) inside or within the vicinity of the boiler.
Fittings and Modifications
Only a competent engineer in accordance with the Gas Safety
(Installation and Use) Regulations can remove the outer case and carry
out any work.
Do not open the appliance.
Any misuse or unauthorised modifications to the boiler, flue or
associated components and system will invalidate the warranty.
Do not modify the boiler or flue system in any way.
Worcester, Bosch Group accepts no liability arising from any such
actions. This does not affect your statutory rights.
CE label
The appliance complies with the basic requirements of the relevant
European directives.
Conformity has been substantiated by the proper documents which -
together with the declaration of filed with the conformity - are
manufacturer.
Abbreviations
CH (boiler) flow = Central Heating flow
CH return = Central Heating return
DHW outlet = Domestic Hot Water warm outlet
MCW inlet = Mains Cold Water inlet
UBA 3 = Universal Burner Automat 3.
2 General Information
Servicing
The boiler must be serviced regularly by a competent, qualified
person, such as a Worcester service engineer or other Gas Safe
registered engineer.
Always use original spares, to help maintain the economy, safety and
reliability of the boiler and have the Service Record completed in the
Installation Checklist.
3 Energy efficiency
The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Ensure that the service engineer completes the Service
Record after each service.
The Installation Checklist and service interval record can
be found at the rear of the Installation, Commissioning
and Servicing Instructions.
Product data Symbol Unit 7736700642 7746900822 87470248 87470250
Product type GB162-50
G20
GB162-65
G20
GB162-80
G20
GB162-100
G20
Condensing boiler Yes Yes Yes Yes
Rated heat output Prated kW 47 61 82 95
Seasonal space heating energy efficiency ηs% 93 92
Energy efficiency class A A
Useful heat output
At rated heat output and high temperature regime 1)
1) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
P4kW 46.6 60.5 82.0 94.5
At 30 % of rated heat output and low temperature regime 2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P1kW 15.4 20.1 26.6 31.6
Useful efficiency
At rated heat output and high temperature regime 1) η4% 87.3 87.3 88.2 88.4
At 30 % of rated heat output and low temperature regime 2) η1% 97.3 97.3 97.3 98.3
Auxiliary electricity consumption
At full load elmax kW 0.045 0.073 0.100 0.145
At part load elmin kW 0.021 0.019 0.024 0.027
In standby mode PSB kW 0.008 0.004 0.008 0.008
Other items
Standby heat loss Pstby kW 0.085 0.082 0.082 0.082
Ignition burner power consumption Pign kW 0.000 0.000 0.000 0.000
Emissions of nitrogen oxides NOx mg/kWh 15 36 42 49
Sound power level, indoors LWA dB(A) 54 60
Table 2 Product data for energy consumption


Produktspezifikationen

Marke: Worcester
Kategorie: Durchlauferhitzer und Boiler
Modell: GB162-100

Brauchst du Hilfe?

Wenn Sie Hilfe mit Worcester GB162-100 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Durchlauferhitzer und Boiler Worcester

Bedienungsanleitung Durchlauferhitzer und Boiler

Neueste Bedienungsanleitung für -Kategorien-