INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
DANGER
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS... ........................................................................2
ALL RIGHTS RESERVED 2 ..........................................................
SPECIFICATIONS................ 3 ......................................................
SAFETY
SAFETY DEFINITIONS ..............................................................4
SAFETY SYMBOLS 4
SAFETY INSTRUCTIONS ..........................................................5
SAFETY LABELS .......................................................................7
CO SENSOR ..............................................................................8
CONTROL PANEL CO AUTO-SHUTOFF 8 ..................................
COMPONENTS
CONTROL PANEL COMPONENTS ...........................................9
GENERATOR COMPONENTS 10 ................................................
CARTON CONTENTS ..............................................................11
ASSEMBLY
INITIAL OIL FILL.......................................................................11
FUEL .........................................................................................12
OPERATION
GENERATOR LOCATION 13 ........................................................
GROUNDING....................... 13 ....................................................
HIGH ALTITUDE OPERATION .................................................13
BREAK-IN PERIOD ..................................................................14
FREQUENCY OF USE .............................................................14
BEFORE STARTING THE GENERATOR 14 ................................
STARTING THE ENGINE .........................................................14
STOPPING THE ENGINE ........................................................14
ECO MODE ..............................................................................15
AC CIRCUIT BREAKERS ........................................................15
OVERLOAD RESET .................................................................15
POWER MANAGEMENT .........................................................16
EXTENSION CORDS 17 ...............................................................
PARALLEL OPERATION 18 ..........................................................
TRANSPORTING .....................................................................18
MAINTENANCE
MAINTENANCE SCHEDULE 19 ...................................................
MAINTENANCE REPLACEMENT PARTS 19 ...............................
ENGINE SERVICE COVER .....................................................19
AIR FILTER MAINTENANCE 19 ...................................................
ENGINE OIL LEVEL CHECK 20 ...................................................
ENGINE OIL CHANGE 20 .............................................................
SPARK PLUG MAINTENANCE 21 ................................................
SPARK ARRESTOR SERVICE ................................................21
STORAGE ................................................................................22
DRAINING THE FUEL TANK ...................................................22
VALVE CLEARANCE 23 ...............................................................
TROUBLESHOOTING 24 .............................................................
EXPLODED VIEWS
EXPLODED VIEWS............ 25 .....................................................
SCHEMATICS
SCHEMATICS...........................................................................31
ESPAÑOL ..............................................................................32
FRANÇAIS .............................................................................56
Westinghouse Outdoor Power Equipment, LLC | 3
SPECIFICATIONS
Speciî·”cations
Running Watts: 3000
Peak Watts: 3700
Rated Voltage: 120V
Rated frequency: 60 Hz
Phase: Single phase
Total Harmonic
Distortion: ≤ 3%
Engine Displacement: 150 cc
Starting Type: Recoil
Fuel Capacity: 1.26 Gallon (4.8 L)
Fuel Type: 87–93 octane*
Oil Capacity: 0.53 US qt (0.5 L)
Oil Type: 10W-30
Spark Plug: 97109 (F7RTC)
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Floating neutral
Voltage Regulator: Digital
Alternator Type: Permanent magnet
Maximum Ambient
Temperature: 104°F (40°C)
Certications: • EPA
• CARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
NOTICE
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must always
be operated outdoors in a well-ventilated area and away
from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scanning the following QR code with your smartphone
camera. You will be directed to the mobile registration
link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-
free warranty coverage.
INTRODUCTION


Produktspezifikationen

Marke: Westinghouse
Kategorie: Generator
Modell: WH3700iXLTc

Brauchst du Hilfe?

Wenn Sie Hilfe mit Westinghouse WH3700iXLTc benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Generator Westinghouse

Bedienungsanleitung Generator

Neueste Bedienungsanleitung für -Kategorien-