Westinghouse WGen12000c Bedienungsanleitung

Westinghouse Generator WGen12000c

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Westinghouse WGen12000c (93 Seiten) in der Kategorie Generator. Dieser Bedienungsanleitung war für 66 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/93
USER MANUAL
W 12000Gen c
Portable Generator
Gasoline: 12,000 Running Watts | 15,000 Peak Watts
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.
2 | Westinghouse Outdoor Power Equipment
INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment.
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
INTRODUCTION
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS....................................................................3
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 ................................................................
SAFETY INSTRUCTIONS 5 .......................................................
SAFETY LABELS AND DECALS 7 .............................................
CO SENSOR 8 ............................................................................
ACTION LABEL ........................................................................8
CONTROL PANEL CO AUTO-SHUTOFF 8 ................................
COMPONENTS
GENERATOR COMPONENTS 9 ................................................
CONTROL PANEL COMPONENTS 10 .......................................
DATA CENTER .......................................................................11
MAINTENANCE REMINDERS .............................................. 11
ASSEMBLY
UNPACKING 12 ..........................................................................
CARTON CONTENTS 12 ...........................................................
INSTALL WHEELS AND LIFTING BRACKET 12 ........................
INITIAL OIL FILL 13 ....................................................................
BATTERY INSTALLATION 13 .....................................................
FUEL ......................................................................................14
GROUNDING 14 .........................................................................
OPERATION
GENERATOR LOCATION 16 ......................................................
HIGH ALTITUDE OPERATION ..............................................16
REMOTE START ...................................................................16
BREAK-IN PERIOD 17 ...............................................................
LOW IDLE 17 ..............................................................................
BEFORE STARTING THE GENERATOR 17 ..............................
STARTING THE ENGINE ......................................................17
STOPPING THE ENGINE ......................................................18
FREQUENCY OF USE 18 ..........................................................
AC CIRCUIT BREAKERS 18 ......................................................
POWER MANAGEMENT 19 .......................................................
EXTENSION CORDS 19 ............................................................
ST SWITCH 20 ............................................................................
TRANSPORTING 20 ...................................................................
MAINTENANCE SCHEDULE 22 ................................................
MAINTENANCE REPLACEMENT PARTS 22 ............................
AIR FILTER MAINTENANCE 22 .................................................
ENGINE OIL CHANGE 23 ..........................................................
SPARK PLUG MAINTENANCE 24 .............................................
SPARK ARRESTOR SERVICE ..............................................24
FUEL FILTER 24 .........................................................................
BATTERY MAINTENANCE 25 ....................................................
BATTERY REPLACEMENT 25 ...................................................
STORAGE 25 ..............................................................................
VALVE CLEARANCE 26 .............................................................
TROUBLESHOOTING 27 ...........................................................
EXPLODED VIEWS AND PARTS LISTS
ENGINE EXPLODED VIEW 28 ...................................................
ENGINE PARTS LIST ... ........................................................29
ENGINE PARTS LIST CONTINUED 31 ......................................
GENERATOR EXPLODED VIEW 32 ..........................................
GENERATOR PARTS LIST ....................................................33
... ............................................................................................33
GENERATOR PARTS LIST CONTINUED 34 .............................
... ............................................................................................34
SCHEMATICS
SCHEMATICS 35 ........................................................................
ESPAÑOL .............................................................................36
FRANÇAIS ...........................................................................65
Westinghouse Outdoor Power Equipment | 3
INTRODUCTION
SPECIFICATIONS
Speciî·”cations
Running Watts: 12,000
Peak Watts: 15,000
Rated Voltage: 120/240V
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic
Distortion: ≤ 5%
Engine Displacement: 713 cc
Starting Type: Recoil, Electric Start,
Remote
Fuel Capacity: 10.5 Gallons (40 Liter)
Fuel Type: Unleaded gasoline
87–93 octane*
Oil Capacity: 1.7 US Quart (1.6 Liter)
Oil Type: SAE 10W-30
Spark Plug: TORCH F7TC
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
Battery: 511092
AC Grounding System: Bonded to frame
Voltage Regulator: AVR
Alternator Type: Brushed
Maximum Ambient
Temperature: 104°F (40°C)
Certications: • EPA
• CARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
UPDATES
The latest User Manual for your Westinghouse
generator can be found under our support tab. https://
westinghouseoutdoorpower.com/pages/manuals
Or scan the following QR code with your smartphone
camera to be directed to the link.
NOTICE
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (-15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must always
be operated outdoors in a well-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scan the following QR code with your smartphone
camera to be directed to the mobile registration link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.


Produktspezifikationen

Marke: Westinghouse
Kategorie: Generator
Modell: WGen12000c

Brauchst du Hilfe?

Wenn Sie Hilfe mit Westinghouse WGen12000c benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Generator Westinghouse

Bedienungsanleitung Generator

Neueste Bedienungsanleitung für -Kategorien-