Instructions electronic Paxos Advance double lock keypad lock
MANY THANKS!
You have chosen a product tested according to EN1143- 1.
A Swiss quality product with VdS-tested security .
Please read these instructions carefully before operating your safe!
Opening the lock
"CLOSE" position
= "OPEN" position
ï‚· First turn the opening handle anti-clockwise in the closed position (horizontal). This will release
the bolt.
 Press Enter and the display will show ‘date, time and secured’. Press Enter again and the
display will show ‘Open menu’.
 Press Enter and the display will show ‘code lock 1......’. Enter code OCa1 11 22 33 10 or code
OCb1 11 22 33 20 and confirm by pressing Enter.
 The message ‘Lock 1 opening’ will be displayed, followed by ‘lock opened’ and ‘code lock 2
......’. Enter code OCa2 12 22 33 10 or code OCb2 12 22 33 20 and confirm by pressing Enter.
‘Lock 2 opening’ will be displayed, followed by ‘Locks open, open bolt’. Now the opening
handle can be pushed down to open the safe door. Display will show ‘Unlock ’ as well as the ed
date and time.
ï‚· The CLR button can be used if a mistake is made while entering the code or if you want to go
one step back in the menu while programming.
Closing the lock
ï‚· Close the safe door. Turn the opening handle anti-clockwise into the closed position
(horizontal). The lock closes automatically and is therefore secured.
Important information:
The Paxos Advance lock system (double-lock version) contains 2 user codes and 1 master code.
Up to 95 staff codes can also be defined per lock. The following factory codes are pre-
programmed:
The following codes changed: The following codes changed: must be can be
Lock 1:
User code 01 : 11 22 33 10 Master code 00 (OCa1) (MA1): 11 99 88 77
User code 02 (OCb1): 11 22 33 20
Lock 2:
User code 01 :(OCa2) 12 22 33 10 Master code 00 : 12 99 88 77 (MA2)
User code 02 (OCb2): 12 22 33 20 (The lock cannot be opened with the master codes;
they are required for defining the staff codes)
The electronic Paxos Advance high security lock is usually in ‘Sleep mode’ (energy-saving
mode). The lock can be ‘woken up’ by pressing the ENTER button.
Code reprogramming
WARNING: User codes 1 and 2 for locks 1 and 2 must both be reprogrammed, because a
third party could be aware of the factory code and may therefore be able to open
the safe.
User code 01 (OCa1) Lock 1
 When the lock is open, press ENTER, confirm request ‘Code functions’ by pressing ENTER
again
 Select ‘01 OCa1’ using the arrow key and confirm by pressing ENTER
 Display shows ‘change’, confirm by pressing ENTER
ï‚· Enter current code 1 (OCal1) (11 22 33 10 at first use) and confirm by pressing ENTER
ï‚· Enter new code (6-8 digits) and confirm by pressing ENTER
 Re-enter new code and confirm by pressing ENTER. Display shows ‘Code saved’
ï‚· Turn the opening handle upward, the lock closes, test the new code at least 3 times with the
door open
Produktspezifikationen
Marke: | WALDIS |
Kategorie: | Tresore |
Modell: | Premium 1500 Kluis |
Brauchst du Hilfe?
Wenn Sie Hilfe mit WALDIS Premium 1500 Kluis benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Tresore WALDIS
6 Juli 2024
Bedienungsanleitung Tresore
- Tresore FERM
- Tresore Yale
- Tresore Chubb
- Tresore Master Lock
- Tresore Phoenix
- Tresore Salvus
- Tresore SentrySafe
- Tresore SereneLife
- Tresore Clarke
- Tresore Barska
- Tresore Kaso
Neueste Bedienungsanleitung für -Kategorien-
7 Juli 2024
7 Juli 2024
6 Juli 2024
6 Juli 2024
6 Juli 2024
6 Juli 2024
6 Juli 2024
6 Juli 2024
5 Juli 2024
5 Juli 2024