SLAVE dimmer 120 V~ 60 Hz for incandescent lamps 40-500 W electronic
transformers 40-300 VA, CFL lamps 10-200 W, LED lamps 3-200 W, control from
universal MASTER dimmer with load adapter, protection fuse, installation on
DIN rails (60715 TH35), occupies 4 modules size 17.5 mm. For nautical scope.
MOSFET+TRIAC microprocessor technology, works in both LE (Leading Edge) and TE (Trailing
Edge) modes, equipped with protection fuse, can be installed on DIN rails (60715 TH35). It does
not require connecting to the busbar, but the sync signal from a MASTER dimmer for DIN rails
01985.120. No buzzing whatsoever.
IMPORTANT: Lamps controllable from a single master or slave dimmer must all be the same.
All controllable loads must be declared DIMMERABLE by the manufacturer. Check the type
of compatible dimmering on the lamp package: LE (Leading Edge) or TE (Trailing Edge). If it is
not specified, the lamp can operate in both modes (chosen at the discretion of the installer).
CHARACTERISTICS.
ā¢ī Ratedīsupplyīvoltageīmains:ī120īV~,ī60īHz
ā¢ī Dissipatedīpower:ī7.4īWī
ā¢ī Terminals:īN neutral, load, phase, synchronizationL S
ā¢ī ProtectionīfuseītypeīF5AH250V
ā¢ī SLAVEīdimmersīneedīaīsynchronismīsignalītoīfunction
ā¢ī Softīstart:ī ensuresīgradualīlightingīfromī zeroītoī maximumī orīpresetīlightingīlevels.ī Thisīwayī
the life of a lamp is increased by reducing stress on the filament and prevents light flash.
ā¢ī Flashīstart:ī usedī withī compactī fluorescentīlamps,ī ensuresī thatī theī lampsī areīswitchedī onī
correctly, reducing any difficulties to a minimum.
ā¢ī Softīend:īīslowlyībringsītheīloadīdownīfromīonītoīoff.
ā¢ī Lightingīlevelīisīsavedīwhenīturnedīoffī(unlessīthereīisīaīblackout);
ā¢ī LeadingīEdgeī mode:ī ī usedīwithī incandescentī lamps,ī compactī fluorescentīlampsīandī LEDī
compatible lamps, as well as
L
type electronic transformers.
ā¢ī TrailingīEdgeī mode:īī usedīwithī compatibleī loadsīsuchīasī fluorescentīlamps,īLEDīlampsī orī
C
type electronic transformers.
ā¢ī Protectionīagainstīshort-circuitingīwhenīturningīonīwithīflashingīblow-outīindicator.
ā¢ī Thermalīprotectionīwithīflashingīblow-outīindicator.
ā¢ī InstallationīonīDIN rails (60715 TH35) , occupies 4 modules of 17.5 mm.
CONFIGURATION.
WARNING: When connecting MASTER-SLAVE, the SLAVE must be configured (using the
dip-switches) in the same operating mode as the MASTER.
The dimmer 01986.120 can be configured by the two dip switches which are accessible from
theīfront:
INSTALLATION RULES.
Installation should be carried out in compliance with the current regulations regarding the instal-
lation of electrical systems in the country where the products are installed.
ā¢ī Itīshouldībeīusedīinīplacesīatīaītemperatureīofībetweenī-5Ā°Cīandī+45Ā°C.
ā¢ī Theīlampsīconnectedītoītheīmasterīorīslaveīmustīallībeītheīsame.
ā¢ī Notīsuitableīforīcontrollingīmotorsī(e.g.īfans,īventilators).
ā¢īTheīratedīpowerīlevelīshouldīneverībeīexceeded.
Controllable loads LE TE
40 to 500 W 40 to 300 W
10 to 100 W 10 to 200 W (Max 5 lamps) (Max 10 lamps)
3 to 100 W 3 to 200 W (Max 5 lamps) (Max 10 lamps)
Electronic transformers
for halogen lamps
40 to 300 W
(Max 3 transformers type
L
)
40 to 300 W
(Max 5 transformers type
C
)
Dimmering with Leading Edge mode Dimmering with Trailing Edge mode
ā¢ī Overloading,ī powerī surgesī andī short-circuitsī mayī irreparablyī damageī dimmers.ī Beforeī
installation check the circuit carefully and eliminate any of the above causes.
ā¢ī Theī dimmerī doesī notī haveī aī mechanicalī circuitībreakerī inī theī mainī circuitī andī soī isī notī
galvanically separated. The circuit load should be considered always powered.
For further instructions see the manual enclosed with the control panel.
CONFORMITY TO STANDARDS.
For MARINE use,īthisīdeviceīhasībeenīsubmittedītoītheīfollowingītests:
IECī60068-2-52ī-īTestīKb:īSaltīmist,īcyclicī(sodium,īchlorideīsolution),
IECī60068-2-6ī-īTestīFc:īVibrationī(sinusoidal)
This device complies with part 15 of the FCCīRulesī(withītheīlimitsīforīaīClassīBīdigitalīdevice).ī
Operationī isī subjectī toī theī followingī twoī conditions:ī (1)ī Thisī deviceī mayī notī causeī harmfulī
interference, and (2) this device must accept any interference received, including interference
that may cause undesidered operation.
FRONT VIEW
CONNECTIONS
MaximumīlengthīofīcablesīconnectingīuniversalīMASTERīdimmerīandīuniversalīSLAVEīdimmer:ī100īm
Connect at least the minimum load required to the universal master dimmer.
A:īIndicatorīLED
B:īDipīswitch
CHANGING FUSE
OFF
1.
Setting
onto TE
Setting
onto LE
Setting onto Flash
instant lighting on maximum
brightness and then it adjusts
linearly to the set brightness
Setting onto Soft
gradual lighting up to the set
brightness
TE
LE
TE
LE
Flash
Soft
Flash
Soft
A
LN
S
N L S
TE Flash
Soft
LE
01986.120
SLAVE
DIMMER
40-500W LE
40-300W TE
120 V~ 60 Hz
B
NLS
NLS
01986.120
SLAVE
TE Fla sh
S oft
LE
DIMMER
120V~
60Hz
40-5 00W LE
40-300 W TE
By-me
NLS
2.
01986.120
01986.12001985.120 01986.120
N L S
TE Flash
Soft
LE
01986.120
SLAVE
DIMMER
40-500W LE
40-300W TE
120 V~ 60 Hz
N L S
TE Flash
Soft
LE
01986.120
SLAVE
DIMMER
40-500W LE
40-300W TE
120 V~ 60 Hz
N L S
01985.120
MASTER DIMMER
120 V~ 60 Hz
40-500W LE
40-300W TE
L
N
Bus
MASTER SLAVE SLAVE
49400503A0 01 1309
VIMAR - Marostica - Italy
Produktspezifikationen
Marke: | Vimar |
Kategorie: | Dimmer |
Modell: | 01986.120 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Vimar 01986.120 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Dimmer Vimar
20 August 2024
18 August 2024
18 August 2024
17 August 2024
16 August 2024
16 August 2024
16 August 2024
15 August 2024
15 August 2024
15 August 2024
Bedienungsanleitung Dimmer
- Dimmer Trust
- Dimmer Cotech
- Dimmer Arendo
- Dimmer Velleman
- Dimmer Eminent
- Dimmer Gira
- Dimmer GE
- Dimmer Tronic
- Dimmer BeamZ
- Dimmer Elro
- Dimmer Steinel
- Dimmer American DJ
- Dimmer TP-Link
- Dimmer ABB
- Dimmer GAO
- Dimmer Hager
- Dimmer Eurolite
- Dimmer JUNG
- Dimmer Sonoro
- Dimmer Merten
- Dimmer GrƤsslin
- Dimmer Intertechno
- Dimmer Homematic IP
- Dimmer Berker
- Dimmer DIO
- Dimmer Handson
- Dimmer InterBar
- Dimmer KlikaanKlikuit
- Dimmer Mercury
- Dimmer Paladin
- Dimmer Peha
- Dimmer Schneider Electric
- Dimmer AMX
- Dimmer Tradim
- Dimmer VAMA
- Dimmer Velbus
- Dimmer Adastra
- Dimmer Eltako
- Dimmer EtiamPro
- Dimmer Chauvet
- Dimmer Chacon
- Dimmer Fibaro
- Dimmer Ltech
- Dimmer Ehmann
- Dimmer Bearware
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
30 September 2024
22 September 2024
15 September 2024
12 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024