![](https://manualstech.ams3.cdn.digitaloceanspaces.com/html/nl/vimar/01985120/html/bg1.png)
Viale Vicenza, 14 - 36063 Marostica VI Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709
www.vimar.com
MASTER dimmer 120 V~ 60 Hz for incandescent lamps 40-500 W electronic
transformers 40-300 VA, CFL lamps 10-200 W, LED lamps 3-200 W, for LED
electronic power supplies, protection fuse, installation on DIN rails (60715
TH35), occupies 4 modules size 17.5 mm. For nautical scope.
ON/OFF switch and adjustment with two built-in buttons. MOSFET+TRIAC microprocessor
technology, works in both LE (Leading Edge) and TE (Trailing Edge) modes. MASTER function,
protection fuse. The device receives commands directly from the Busbar and is able to control
the load directly. It can also control up to 3 SLAVE dimmers for DIN rails 01986.120.
IMPORTANT: Lamps controllable from a single master or slave dimmer must all be the
same. All controllable loads must be declared DIMMERABLE by the manufacturer. Check
the type of compatible dimmering on the lamp package: LE (Leading Edge) or TE (Trailing
Edge). If it is not specified, the lamp can operate in both modes (chosen at the discretion
of the installer).
CHARACTERISTICS.
ā¢ī RatedīsupplyīvoltageīTPīBusbar:ī29īV
ā¢ī Ratedīsupplyīvoltageīmains:ī120īV~,ī60īHz
ā¢ī AbsorptionīfromīTPīBusbar:ī15īmA
ā¢ī Dissipatedīpower:ī7.8īWī
ā¢ī Terminals:īN neutral, load, phase, L Sīsynchronization,īTPīBusbar
ā¢ī ProtectionīfuseītypeīF5AH250V
ā¢ī Functionsīthatīcanībeīaccomplishedīwithītheīdimmer:
- Switching on, off and dimmering
- Changing absolute brightness
- Actuating/saving scenarios
- Enabling "Flash Start" mode for CFL lamps
- "Ramp" operation
- Switch-off delay and warning function
-īPhaseīcutting:īLE/TEī
ā¢ī Localīcontrols:
Pressingītheī button enables using the local buttons. All messages from the busbar are
ignored.
- Briefly pressing the button ī:īONīcontrol
- Briefly pressing the button ī:īOFFīcontrol
-īPressingīandīholdingīdownītheībuttonī ī:īIncreaseībrightness
-īPressingīandīholdingīdownītheībuttonī :īDecreaseībrightness
In normal operation (that is when the commands are sent over the bus) pressing the buttons
for the outputs is ignored.
ā¢ī Protectionīagainstīshort-circuitingīwhenīturningīonīwithīflashingīblow-outīindicator.
ā¢ī Thermalīprotectionīwithīflashingīblow-outīindicator.
ā¢ī MASTER-SLAVEī function:ī payingī attentionī notī toī exceedī maximumī powerī controllableī byī
each dimmer. A MASTER device can have up to 3 SLAVE dimmers (art. 01986.120) for a
maximumītotalīloadī ofī2000īWī(VA)īcorrespondingītoī500īW/VAīmaxī connectedītoīeachīofī
the 4 devices.
ā¢ī InstallationīonīDINīrailsī(60715īTH35),īoccupiesī4īmodulesīofī17.5īmm.
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE BY-ME
SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL PANEL.
ā¢īFunctionalīunits:ī1;ītheīunitīcanībelongītoīatīmostī4īdifferentīgroups.
ā¢ī Selectingī theī functionalī unitī (configuration):ī duringī groupī creation,ī whenī theī controlī panelī
requiresīpressingītheīdeviceībutton:ī
-īItīisīrecommendedītoīconfigureītheīdeviceīwithītheīloadīOFF;
-īPressītheīCONFībutton,ītheīredīLEDīwillīlightīup;
-ī Withī theī redī LEDī on,ī theī controlī panelī willī configureī theī functionalī unit;ī atī theī endī ofī thisī
operation the red LED will go out.
Controllable loads LE TE
40 to 500 W 40 to 300 W
10 to 100 W 10 to 200 Wī(Maxī5īlamps) (Max 10 lamps)
3 to 100 W 3 to 200 Wī(Maxī5īlamps) (Max 10 lamps)
Electronic transformers
for halogen lamps
40 to 300 W
(Max 3 transformers type
L
)
40 to 300 W
(Maxī5ītransformersītypeī
C
)
Dimmering with Leading Edge mode Dimmering with Trailing Edge mode
INSTALLATION RULES.
Installation should be carried out in compliance with the current regulations regarding the instal-
lation of electrical systems in the country where the products are installed.
ā¢ī Itīshouldībeīusedīinīplacesīatīaītemperatureīofībetweenī-5Ā°Cīandī+45Ā°C.
ā¢ī Theīlampsīconnectedītoītheīmasterīorīslaveīmustīallībeītheīsame.
ā¢ī Notīsuitableīforīcontrollingīmotorsī(e.g.īfans,īventilators).
ā¢īTheīratedīpowerīlevelīshouldīneverībeīexceeded.
ā¢ī Overloading,ī powerī surgesī andī short-circuitsī mayī irreparablyī damageī dimmers.ī Beforeī
installation check the circuit carefully and eliminate any of the above causes.
ā¢ī Theī dimmerī doesī notī haveī aī mechanicalī circuitī breakerī inī theī mainī circuitī andī soī isī notī
galvanically separated. The circuit load should be considered always powered.
For further instructions see the manual enclosed with the control panel.
CONFORMITY TO STANDARDS.
For MARINE use,īthisīdeviceīhasībeenīsubmittedītoītheīfollowingītests:
IECī60068-2-52ī-īTestīKb:īSaltīmist,īcyclicī(sodium,īchlorideīsolution),
IECī60068-2-6ī-īTestīFc:īVibrationī(sinusoidal)
Thisīdeviceīcompliesīwithīpartī15īofītheīFCC Rules (with the limits for a Class B digital device).
Operationī isī subjectī toī theī followingī twoī conditions:ī (1)ī Thisī deviceī mayī notī causeī harmfulī
interference, and (2) this device must accept any interference received, including interference
that may cause undesidered operation.
FRONT VIEW
CONNECTIONS
MaximumīlengthīofīcablesīconnectingīuniversalīMASTERīdimmerīandīuniversalīSLAVEīdimmer:ī100īm
Connect at least the minimum load required to the universal master dimmer.
A:īIndicatorīLED
B:īSwitchingīonīandīincreasingībrightness
C:īSwitchingīoffīandīdecreasingībrightness
D:īLEDīandīconfigurationībutton
CHANGING FUSE
OFF
1.
01985.120
MASTER DIMMER
120V~
60Hz
40-50 0W LE
40-300W T E
CONF.
NLS
By-me
NLS
BUS
NLS
2.
01986.12001985.120 01986.120
N L S
TE Flash
Soft
LE
01986.120
SLAVE
DIMMER
40-500W LE
40-300W TE
120 V~ 60 Hz
N L S
TE Flash
Soft
LE
01986.120
SLAVE
DIMMER
40-500W LE
40-300W TE
120 V~ 60 Hz
N L S
01985.120
MASTER DIMMER
120 V~ 60 Hz
40-500W LE
40-300W TE
L
N
Bus
MASTER SLAVE SLAVE
A
B
C
D
BUS TP
LN
S
N L S
01985.120
MASTER DIMMER
120 V~ 60 Hz
40-500W LE
40-300W TE
01985.120
49400502A0īī01īī1309
VIMAR - Marostica - Italy
Produktspezifikationen
Marke: | Vimar |
Kategorie: | Dimmer |
Modell: | 01985.120 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Vimar 01985.120 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Dimmer Vimar
![Vimar](/images/pdf_free.png)
20 August 2024
![Vimar](/images/pdf_free.png)
18 August 2024
![Vimar](/images/pdf_free.png)
18 August 2024
![Vimar](/images/pdf_free.png)
17 August 2024
![Vimar](/images/pdf_free.png)
16 August 2024
![Vimar](/images/pdf_free.png)
16 August 2024
![Vimar](/images/pdf_free.png)
16 August 2024
![Vimar](/images/pdf_free.png)
15 August 2024
![Vimar](/images/pdf_free.png)
15 August 2024
![Vimar](/images/pdf_free.png)
15 August 2024
Bedienungsanleitung Dimmer
- Dimmer Trust
- Dimmer Cotech
- Dimmer Arendo
- Dimmer Velleman
- Dimmer Eminent
- Dimmer Gira
- Dimmer GE
- Dimmer Tronic
- Dimmer BeamZ
- Dimmer Elro
- Dimmer Steinel
- Dimmer American DJ
- Dimmer TP-Link
- Dimmer ABB
- Dimmer GAO
- Dimmer Hager
- Dimmer Eurolite
- Dimmer JUNG
- Dimmer Sonoro
- Dimmer Merten
- Dimmer GrƤsslin
- Dimmer Intertechno
- Dimmer Homematic IP
- Dimmer Berker
- Dimmer DIO
- Dimmer Handson
- Dimmer InterBar
- Dimmer KlikaanKlikuit
- Dimmer Mercury
- Dimmer Paladin
- Dimmer Peha
- Dimmer Schneider Electric
- Dimmer AMX
- Dimmer Tradim
- Dimmer VAMA
- Dimmer Velbus
- Dimmer Adastra
- Dimmer Eltako
- Dimmer EtiamPro
- Dimmer Chauvet
- Dimmer Chacon
- Dimmer Fibaro
- Dimmer Ltech
- Dimmer Ehmann
- Dimmer Bearware
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
![American DJ](/images/pdf_free.png)
30 September 2024
![Elro](/images/pdf_free.png)
22 September 2024
![ABB](/images/logos/abb.png)
15 September 2024
![DIO](/images/pdf_free.png)
12 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024
![Ltech](/images/pdf_free.png)
5 September 2024