1. – IMPORTANT SAFETY INSTRUCTIONS SAVE
THESE INSTRUCTIONS!
In general
Please read the documentation supplied with this product first, so that you are familiar with the
safety signs en directions before using the product.
This product is designed and tested in accordance with international standards. The equipment
should be used for the designated application only.
Warning – These servicing instructions are for use by qualified
personnel only. To reduce the risk of electric shock, do not
perform any servicing other than that specified in the operating
instructions unless you are qualified to do so.
WARNING: ELECTRIC SHOCK HAZARD
The product is used in conjunction with a permanent energy source (battery). Input and/or output
terminals may still be dangerously energized, even when the equipment is switched off. Always
disconnect the battery before carrying out maintenance or servicing the product.
The product has no internal user serviceable components. Do not remove the front plate or -
operate the product if any panels have been removed. All servicing must be undertaken by
qualified personnel.
Please read the installation instructions in the installation manual before installing the equipment.
This is a Safety Class I product (supplied with a protective grounding terminal). The chassis must
be grounded. A grounding point is located on the outside of the product. Whenever it is likely that
the grounding protection has been damaged, the product must be turned off and secured against
unintended operation; please contact qualified service staff.
The AC output is isolated from the DC input and the chassis unless the unit is equipped with a
Ground Fault Circuit Interrupter (GFCI). Units with a GFCI have AC output neutral
connected to chassis inside the device by default. A qualified installer should check this
connection since it is necessary for the GFCI to function properly. Local regulations may
require a true neutral. In this case one of the AC output wires must be connected to the chassis,
and the chassis must be connected to a reliable ground. Please note that a true neutral is
needed to ensure correct operation of an earth leakage circuit breaker.
Ensure that the equipment is used under the correct ambient conditions.
Never operate the product in a wet or dusty environment.
Never use the product where there is a risk of gas or dust explosions.
Ensure there is adequate free space (10 cm) for ventilation around the product and check that the
ventilation vents are not blocked.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Use of an attachment not recommended or sold by the marine unit manufacturer may result in a
risk of fire, electric shock, or injury to persons.
2
2. Description
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• l Apple and Android smartphones, tablets and other devices (VE.Direct to B uetooth Smart
dongle needed)
Fully configurable
• Low battery voltage alarm trip and reset levels
• - - Low battery voltage cut off and restart levels, or Dynamic Cut off
• - Output voltage 210 245 V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring
Battery voltage utput voltage, load indicator, AC O , alarms
Proven reliability
The full bridge toroidal transformer topology has proven its reliability over many years.with
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, filament lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value. It will switch on and check every few seconds, adjustable, if the load has increased again.
Remote on/off connector
A remote on/off switch can be connected to a two-pole connect or or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
A red and a green LED indicate inverter operation and status of the different protections.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax
features a very short switchover time (less than 20 milliseconds) so that computers and other
electronic equipment will continue to operate without disruption.
Available with different output sockets
Schuko, UK (BS 63), AU/NZ (3112) or IEC-13 -320 (male plug included)


Produktspezifikationen

Marke: Victron Energy
Kategorie: Nicht kategorisiert
Modell: Phoenix 250VA

Brauchst du Hilfe?

Wenn Sie Hilfe mit Victron Energy Phoenix 250VA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Victron Energy

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-