Ventev TW-HCEN-FLP Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Ventev TW-HCEN-FLP (3 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
www.ventev.com/infra sales@ventev.com 800.851.4965
Universal Flush Mount
Ceiling Enclosure Installation
Instructions for Installation
1) To install the flush mount, cut an opening into the
ceiling drywall as shown in Figure 1. (TIP: Drill
holes at the corners of the cutout and cut between
the holes.) The chamfered corners of the profile
are necessary to allow the lid to completely cover
the cutout.
Figure 1. Figure 2.
2) Loosen the thumbscrews on the backplate of the base
assembly and remove.
3) Rotate the clamp arms in so they are against
the base as shown. With the base held close
to the ceiling opening, route the ethernet cable
through the knockout hole in the base. A
Romex connector is supplied to securely clamp
the cable to the enclosure.
Figure 3. Figure 4.
4) Insert the base into the ceiling opening, making sure
that the sides of the base with the clamp arms are in
line with the 11 ¼” sides of the opening.
www.ventev.com/infra sales@ventev.com 800.851.4965
Universal Flush Mount
Ceiling Enclosure
5) Holding the base in the ceiling, turn the 4 plastic
screws with a screwdriver until the drywall is
clamped between the clamp arms and the base
flanges.
6) For the Cisco Low Profile Universal Bracket, install
using the included #8-32 screws (QTY 4) . Additional
AP mounting options shown in Figure 6B.
Figure 5. Figure 6A.
Meraki MR 33 & 42 Cisco Universal Bracket Optional T Bar Bracket
Figure 6B.
Sheet metal screws (Qty 4) are provided to attach other AP brackets.
www.ventev.com/infra sales@ventev.com 800.851.4965
Universal Flush Mount
Ceiling Enclosure
7) Install the access point to the AP Bracket. Cisco AP
shown below for reference.
8) Hold the AP with backplate close to the base in the
ceiling and connect the ethernet cable. Orient the
backplate so that the notch in the backplate lines up
with the cable grip. With AP and backplate held against
the base, fasten backplate to base using a Phillips
head screwdriver and captive screws.
Figure 7. Figure 8.
Figure 9.
9) Complete the installation by attaching the cosmetic
cover to the base by fastening with captive security
head screws. (A security bit is supplied). Plastic
screw head covers are also provided to cover
the screws, if desired.

Produktspezifikationen

Marke: Ventev
Kategorie: niet gecategoriseerd
Modell: TW-HCEN-FLP

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ventev TW-HCEN-FLP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Ventev

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung für -Kategorien-