COMPLEMENTS FOR CIVIL SERIES
TECHNICAL INFORMATION
MIRALight indicators
1 Installation on ush-mounting boxes with a height of 45 mm
2 Terminals on the back of the device for power supply connection
Not extractable step marker lamp that turns on and stays on only when the power is on.
Muvy is small and compact to be installed with discretion in the flush-mounting boxes of any room
and is supplied with adapters that allow installation with the plates of the main civil series.
LIGHT INDICATORS
3 models available, which dier in the colour of the light emitted:
green, white, red
The light turns on when the device is powered
Compact size: only 1 module occupied in the ush-mounting box
Adapters that allow adaptability with the main civil series
(see Adaptable plates”) included in the package
Code Model Description Colour Power supply
VE771000 Mira Verde 230 V~Signaling lamp compact size Green
VE771100 Mira Bianca Signaling lamp compact size Opal white 230 V~
VE770900 Mira Rossa Signaling lamp compact size Red 230 V~
Adaptable plates
ABB Mylos series
Ave S44 series
Bticino Axolute series
Bticino Axolute Air series
Bticino Light series
Bticino Living International series
Bticino LivingLight series (LL)
Bticino LivingLight Air series
Bticino Matix series
Gewiss Chorus series
Vimar Arké series
Vimar Eikon series
Vimar Eikon Evo series
Vimar Plana series
For information on the possibility of using dierent plates
contact the technical assistance service
CONNECTION DIAGRAM
DIMENSIONS
(mm)
Front view Side view Diagram
REFERENCE STANDARDS
Compliance with the Community Directives: 2014/35/EU (LVD) and 2014/30/EU (EMCD)
is declared in reference to the following harmonized standards: EN 60598-1 • EN 60598-2-2 • EN 61000-6-1 • EN 61000-6-3
Power supply V AC 230 (-15% ÷ +10%)
Absorption VA (W) 7 (0.5)
Frequency 50/60Hz
Mounting ush
Maximum cables section mm21.5
Operating temperature 0 ÷ 50°C
Storage temperature -10 ÷ +65°C
Operating humidity 20% ÷ 90% RH
non condensing
Protection degree IP40
GENERAL CHARACTERISTICS
External switch: lamp on/o
MIRA-ENG-072019


Produktspezifikationen

Marke: Vemer
Kategorie: Nicht kategorisiert
Modell: Mira

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer Mira benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Vemer

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-