65
91
micro AST
18
TIME AND MANAGEMENT
GENERAL CHARACTERISTICS
TECHNICAL INFORMATION
CONNECTION DIAGRAMDIMENSIONS (mm)
Front view Side view Diagram
Time switch to manage electric utilities over time between sunrise and sunset time calculated according to
the set geographical area.
Through virtual trippers it’s possible to program one or more night intervals during which the load stays
unactive.
Particularly suitable to light shops, luminous signs, fountains, etc.
The cover on the front of the device allows for the replacement of the depleted battery.
Micro ASTAstronomical time switches
1 Backlit display to visualize programming, time and relay status
2 Container: 1 DIN module
3 Text guide
4 24-hours dial with virtual trippers
5 Cover for battery replacement
DIGITAL ASTRONOMICAL TIME SWITCHES
• Power supply: 230 V AC 50/60 Hz
• Available programming:
- P1 xed with possibility of night-switch OFFs of minimum 30 minutes
• Sunrise and sunset times are calculated according to phone prex (for Italy) or
geographical coordinates
• Display of the calculated sunset/sunrise times
• Correction of sunrise and sunset time: ± 120 minutes
• Automatic summer time update
• Manual override of the relay (temporary or permanent)
• Battery life: 4 years (replaceable just removing the cover)
• Depleted battery signal
• Relays switching only with power supply
Code Model Description n. relays
VE762300 Micro AST Astronomical time switch with simplied programming 1
Program
• switch ON and switch OFF always visible
• night switch OFF have a minimum
duration of 30 minutes
• each switch ON/OFF of load occurs
exactly at the calculated sunset-sunrise
time (resolution per minute)
P1 ON
OFF
Sunset Sunrise
REFERENCE STANDARDS
Compliance with Community Directives:
2014/35/EU (LVD) • 2014/30/EU (EMCD)
is declared with reference
to the following standards:
EN 60730-2-7
Power supply 230 (-15% ÷ +10%)V AC
Frequency Hz 50 / 60
Absorption VA 5.5
W 1
Output 1 relay normally open
Capacity at 250 V AC 16 (10)A
Battery life 4 years (Lithium battery CR-1632)
Charge reserve (for battery replacement) 1 minute
Switchings in case of power failure NO
Programming resolution for night-switch OFFs 30 minutes
Operating precision ± 1 second/day at 25°C
Operating temperature -20 ÷ +50°C
Storage temperature -10 ÷ +70°C
Operating humidity 20÷90% non condensing
Container 1 DIN module
Degree of protection IP20
CONNECTABLE LOADS
Incandescent 2000 W
Fluorescent (compensated) 250 VA
Low voltage halogen 1000 VA
Halogen (230 V~) 2000 W
Low consumption (CFL) 200 VA
Low consumption (Downlights) 200 VA
Led 25 VA
1 2
3
4
5
MICRO AST-ENG-201903


Produktspezifikationen

Marke: Vemer
Kategorie: Schalten
Modell: Micro AST

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer Micro AST benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalten Vemer

Bedienungsanleitung Schalten

Neueste Bedienungsanleitung für -Kategorien-