Vemer DUET-D Bedienungsanleitung

Vemer Schalter DUET-D

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Vemer DUET-D (1 Seiten) in der Kategorie Schalter. Dieser Bedienungsanleitung war für 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
USER MANUAL
ANALOG TIME SWITCH WITH TRIPPERS
Read carefully all instructions
The DUET-D, DUET-ED and time switches control any electrical installation by means DUET-W
of daily (Duet-D/Duet-ED) or weekly (Duet-W) programs. For models DUET-D and DUET-W
the cover on the front of the device makes it possible to replace the battery when it is run down.
They are designed for household and similar operation with normal pollution levels.
SAFETY WARNINGS
1) The device must be installed and activated by qualified personnel, following the
connection diagrams provided in this manual scrupulously
2) After installation, it must be made impossible to access the terminals without
specific tools
3) Before accessing the connection terminals, verify that the leads are not live
4) Do not connect or power the device if any part of it is damaged
5) The device must be installed and activated in compliance with current electric
systems standards
6) Do not use the device for purposes other than those indicated.
Code Model Description
VP879100 DUET-D
Daily analog time switch with power reserve
VE785600 DUET-ED
Daily analog time switch without power reserve
VE125100 DUET-W
Weekly analog time switch with power reserve
TECHNICAL CHARACTERISTICS
• Power supply: 230 V~ 50/60 Hz
• Switching capability: 16 (4) A 250 V~
• Power consumption: 0,5 W
• Operating accuracy: ± 1 second/day at 23°C
• Type of dial: 48 pins
• Minimum time of functioning:
- DUET-D/DUET-ED: 30 minutes
- DUET-W: 3,5 hours (210 minutes)
• Switching accuracy:
- DUET-D/DUET-ED: ± 5 minutes
- DUET-W: ± 35 minutes
• Manual control by 3 positions selector:
- Permanent disconnected0
- Automatic operationA
- Permanent connectedI
• Power reserve: 150 hours (NiMH rechargeable battery – replacing)
only on DUET-D and DUET-W
• Operating temperature: -10 °C ÷ +45 °C
• Protection class: II
• Protection category: IP20
• 2 DIN modules container
PROGRAM
• Lift the transparent cover
• Move all the setting pins towards the interior of the sphere (contact 3-2 remains closed)
• Move the setting pins corresponding to the desired switch on times outwards, in which contact
3-1 remains closed. Each pin corresponds to 30 minutes of functioning for Duet-D/Duet-ED
and 3,5 hours for Duet-W
• The number of pins outwards determines the time of functioning
• Rotate the minute hand clockwise until the index and hands indicate the current time
• Close the transparent cover
• Power the device
• Manual mode: 3 positions are available with the selector.
BATTERY REPLACEMENT
• To replace the battery (only on and DUET-D DUET-W):
- disconnect the power supply
- remove the battery holder
- replace the battery
- connect the power supply
• Use V80H batteries only.
• Throw away the run down batteries in compliance
with current regulations on the disposal of armful waste.
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared in reference to the harmonized standard:
• EN 60730-2-7
DIMENSIONS
CONNECTION DIAGRAMS
BATTERY REPLACEMENT
ISCOM047-1910
DESCRIPTION
16(4) A/230 V~
Battery cover
Index
Programming dial
Manual selector
Incandescent 3000 W
Fluorescent 1200 VA
Low voltage halogen 2000 VA
Halogen (230 V~) 3000 W
Low consumption lamp (CFL 1000 VA
Low consumption lamp (CFL 900 VA
Led 200 VA
Mod. DUET-D
Mod. DUET-ED
Mod. DUET-W


Produktspezifikationen

Marke: Vemer
Kategorie: Schalter
Modell: DUET-D

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer DUET-D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalter Vemer

Bedienungsanleitung Schalter

Neueste Bedienungsanleitung für -Kategorien-