Velbus VMBEL4 Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Velbus VMBEL4 (10 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂĽr 32 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/10
E -L GLASS CONTROL MODULES USER MANUAL DGE IT
v01 1/ 10 www.velbus.eu
EDGE-LIT GLASS CONTROL MODULES
VMBEL1 / VMB 2 / VMBEL EL4 / VMBELO
USER MANUAL
E -L GLASS CONTROL MODULES USER MANUAL DGE IT
v01 2/ 10 www.velbus.eu
Table of Contents
1 Characteristics .................................................................................................................... 3
1.1 General characteristics .......................................................................................................................................................................................... 3
1.2 Specific characteristics of the VMBELO .......................................................................................................................................................... 3
1.3 Specific characteristics of the VMBELO .......................................................................................................................................................... 3
2 How to…? ............................................................................................................................ 4
3 Operating the VMBEL1, VMBEL2 and VMBEL4 ....................................................... 6
3.1 Buttons ...................................................................................................................................................................................................................... 6
3.2 Cleaning mode .................................................................................................................................................................................................. 6
4 Operating the VMBELO ................................................................................................... 7
4.1 Overview and general use ................................................................................................................................................................................... 7
4.2 Operating the thermostats on the VMBELO ........................................................................................................................................... 8
4.3 The VMBELO configuration menu .............................................................................................................................................................. 9
E -L GLASS CONTROL MODULES USER MANUAL DGE IT
v01 3/ 10 www.velbus.eu
1 CHARACTERISTICS
1.1 GENERAL CHARACTERISTICS
• 1, 2 or 4 touch keys (depending on the model)
• dual and multi-button operation
o dual operation: short press activates one function, long press activates another. The duration for long press
can be set at 1, 2, or 3 seconds.
Example: short press is ON, long press for the same button is OFF.
o multi-button operation: a new function is activated every time the button is pressed. Depending on the
model, a series of 4 (VMBEL4) up to 7 (VMBEL1) functions can be set.
Example: setting the ventilation speed with a single button. Press once to set low speed, press twice to set medium
speed, press three times for high speed, press four times to turn OFF. Press again to restart the cycle.
• a built-in temperature sensor and thermostat operation (only usable when the side LEDs are off)
o every glass control module can be used to measure the temperature in the room as well as for heating and
cooling control. The target temperature and operating mode (frost protection, day, night or comfort) can be
selected through manual operation or program steps. The thermostats of other glass control modules can be
displayed and operated (max. 12 modules) on a VMBELO (with OLED screen).
Example: a residence has a glass control module in every room, allowing for manual as well as automatic
operation of both heating and cooling. An extra thermostat is no longer necessary.
• automatic operation via program steps
o most functions can be performed automatically at specific times (daily, weekly, only on weekdays, only on
weekends, etc.). The selected time can be fixed (specific time of day), or linked to sunrise and sunset times.
Example: automatically raise the blinds at sunrise.
o buttons can be (temporarily) locked so they cannot be operated
Example: during working hours the buttons in the private area of a doctor’s office are temporarily locked so patients
cannot operate them inadvertently. Naturally this functionality can be activated or deactivated manually at the
press of a button.
o heating and cooling can also be automated via program steps
Example: on weekdays the heating is set to day mode every morning between 6.30 and 8.30 am and every evening
between 4 pm and 10.30 pm. Outside these hours night mode is activated automatically. On the weekends a
different program is used. The temperature can be adjusted as necessary by pressing a button.
• high and low temperature alarms (4 in total) (only usable when the side LEDs are off)
o when the temperature is higher or lower than a specific value, a specific action can be performed.
Example: when the temperature exceeds 25°C the blinds are lowered automatically. Conversely, when the
temperature is lower than 19°C they are raised automatically.
• the color and intensity of the RGBW leds on the sides can be configured in VelbusLink and modified by actions and
program steps (for ambient lighting as well as feedback lighting)
1.2 SPECIFIC CHARACTERISTICS OF THE VMBELO
• the following can be displayed on the OLED screen of the VMBELO:
o up to 8 pages of 4 push buttons. A name and/or icon can be displayed for each
o a clock page with date and time, both of which can be adjusted
o for every connected glass control module (max. 12) a thermostat page with the current temperature, mode
(day, night, frost protection, ...), target temperature and other information on heating and cooling. Every
thermostat can also be operated (set to day/night/comfort/frost protection; temporarily raise or lower the
temperature, ...)
o consumption of connected pulse counters (total, day total and, for kWh counters, current consumption). (For
more details please consult the documentation of the VMB7IN 7-channel input module)
o readouts of connected analog sensors (VMBMETEO, and VMB4AN sensors)
• the OLED screen has a screensaver to save energy and prevent damage to the screen. In screensaver mode the screen
can either be dimmed or completely turned off, with a configurable delay
• the OLED screen can also be used for the configuration of various settings concerning the clock and the thermostat
(cfr. “The VMBELO configuration menu” p. 9).
1.3 SPECIFIC CHARACTERISTICS OF THE VMBELO
• motion detector for indoor use


Produktspezifikationen

Marke: Velbus
Kategorie: Nicht kategorisiert
Modell: VMBEL4

Brauchst du Hilfe?

Wenn Sie Hilfe mit Velbus VMBEL4 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Velbus

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-