VänEE V160E65RT Bedienungsanleitung

VänEE Airco V160E65RT

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für VänEE V160E65RT (6 Seiten) in der Kategorie Airco. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
®
U Dnit escription
Fresh Air System - 150 CFM
parts motor erv core/ /
F
a
b
r
i
q
u
é
a
u
M
a
d
e
i
n
CANAD
A
CANAD
CANAD
CANAD
CANADA
A
A
A
controls
The industry’s most advanced residential fresh air system, created to offer a
universal platform specifically designed and improved to make contractors
life easier and more profitable while delivering constant superior air
quality.
product specifications subject to change without notice .
Polypropylene crossflow core with polymeric membrane and
aluminum covers, impact resistant, non washable
Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm)
MERV 8 grade washable standard filter (included)
Optional MERV 13 grade filter part no. V242851
Compatible with the Tandem transition (part no. 14690)
(recommended for installations producing up to 110 CFM
only)
ERV
Top ports: V160E65RT
SRE of 76% at 0°C (18 L/s, 36 CFM) and SRE of 71% at 0°C
and 56% at -25°C (31 L/s, 66 CFM)
Ports size: 6 in.
Recirculation defrost
Corrosion resistant galvanized steel door and cabinet
One-piece molded insulation shell, no air leakage
(expanded polystyrene; UL 94 HF-1 certified)
Virtuo constant airflow and auto-balancing device
(patent pending)
Motorized dampers (no additional backdraft dampers required)
No drain required
Recirculate air within the dwelling with recirculation mode
using a main wall control
6’ power cord
Unit electrical characteristics:120 volts, 60 Hz, 2.4 A, 163 W
core
Filters
options
There are 3 optional main controls and 2 optional auxiliary
controls available. Refer to Wall Control specification sheet for
more information.
aUtomatic
a D v a n c e D
toUchscreen
20-40-60
DelUxe
Thanks to the Virtuo Air Technology™, the airflow calibration
and auto-balancing are achieved quickly and maintained
throughout the life of the product
Select the desired CFM (from 35 to 150 CFM, 17 to 71 L/s)
using the proven integrated LCD screen. The airflow is then set
up automatically
Integrated electronic airflow measurement device with real
time LCD
Integrated diagnostic tool
Equipped with PMSM ECM motors for a very low power
consumption
Suspended installation (chains included)
OR
Wall-mount installation (universal brackets included)
installation with 2 brackets
installation with 4 brackets
35 to 150 CFM (17 to 71 L/s) @ 0.2 in. w.g.
35 to 142 CFM (17 to 67 L/s) @ 0.4 in. w.g.
DehUmiDistat
1
Airflow performances associated with MERV 13 optional filter are not HVI certified. However, from tests performed by the manufacturer, such
performances are not affected by the use of this filter.
FRESH AIR
TO BUILDING
EXHAUST AIR
TO OUTSIDE
EXHAUST AIR
FROM BUILDING
FRESH AIR
FROM OUTSIDE
8" (20.32 CM)
CLEARANCE REQUIRED
IN FRONT OF DOOR
FOR MAINTENANCE
19/8"
(48.58 CM)
219/16"
(54.77 )CM
1¼"(3.18 CM)
207/16"
(51.91 )CM
SCREW
FIXATION
18¾" (47.63 )CM
21" (53.34 CM)
16" (40.64 CM)
16/8" (40.96 )CM
11/8"
(28.26 CM)
11/8"
(28.26 CM)
3/16" (9.37 CM) 3/16" (9.37 )CM
VK0126A
4/8" (10.48 )4/ CM8" (10.48 )CM
4½" (11.43 )4½" (1 CM1.43 )CM
21½"
(54.61 )CM
6 p"orts imensions op orts D (t p )
Total assembled weight: approx .37 lb. (16.8 kg) (core included)
Shipping weight: approx. 44 lb. (20 kg)
DeFrost ystem s
d iscretion
(Factory
setting)
o t *utdoor emperature
-5°c -15°cto
23°f 5°fto
-15°c -27°cto
5°f -17°fto
-27°c and less
-17°f and less
cfm a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
0 to 59
25 6 5 714 13
60 to 104
25 6 5 715 14
105 and more
15 6 5 9 710
* Outdoor temperature is read by a thermistor located inside the unit, next to fresh air from
outdoor port.
p o t *lus utdoor emperature
-5°c -15°cto
23°f 5°fto
-15°c -27°cto
5°f -17°fto
-27°c and less
-17°f and less
cfm a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
0 to 59
25 7 7 814 12
60 to 104
25 7 7 815 13
105 and more
15 7 7 9 810
* Outdoor temperature is read by a thermistor located inside the unit, next to fresh air from
outdoor port.
NOTE: There is a 10-minute additional defrost every 5 defrost cycles.
NOTE: There is a 10-minute additional defrost every 5 defrost cycles.
Power cord
Terminals Drain
Latches
HomeshieldTM Defrosting System
Defrost is activated at a temperature
of -5°C (23°F) and lower as specified
within the table. No negative
pressure is created by air exhausted
to the outdoors since the air is
recirculated into the house, helping
to prevent any backdraft.
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville, Québec, Canada J2C 7W9 vanee.ca 800-567-3855
Project: Remarks
Location:
Part no.:
Qty.:
Submitted by: Date:
®
F can Urves with irtUo v
Thanks to Virtuo Air TechnologyTM, no need to balance the unit manually. Both PMSM motors are controlled by an artificial intelligence
performing 120 readings per minute then processing this information to maintain the requested airflow.
For typical installation, Virtuo will ensure a balanced ventilation at every selected speed regardless of the weather conditions, the type of
connection, the variable speed furnace/AHU, the stack effect, the filter clogging and so on. This results in peace of mind for installers and
users knowing that the unit will always remain balanced and that it will maintain its maximum heat/energy recovery efficiency.
static
pressure
(p )a
s
tatic
pressure
( . . .)in w g
net
supply
airflow
(l/ )s
n et
supply
airflow
( )cfm
gross
airflow
supply
(l/ )s
gross
airflow
supply
( )cfm
gross
airflow
exhaust
(l/ )s
gross
airflow
exhaust
( )cfm
25 72 73 730.1 153 155 155
50 0.2 72 7271 150 153 153
75 0.3 69 70 70146 148 148
100 0.4 68 6867 142 144 144
125 0.5 65 66 66138 140 140
150 0.6 63 133 136 13664 64
175 0.7 62 6261 129 131 131
200 0.8 58 59 59123 125 125
225 0.9 56 119 57 57121 121
250 531.0 112 54 54114 114
275 1081.1 51 52 52110 110
300 48 49 491.2 102 104 104
energy erFormance p
r seqUirements anD tanDarDs
CSA C22.2 No. 113 compliant (safety)
UL 1812 compliant (safety)
Could be installed in compliance with CSA F326
Performance tested in accordance with CSA C439 Standard
Compliant with Prop 65
supply
temperature n aet irflow power
c onsumed
watts
s ensible
recovery
efficiency
a djusted
sensible
recovery
efficiency
apparent
s ensible
e *ffectiveness
l atent
recovery /
m oisture
transfer
°C °F l/s cfm
heating
0 32 38 78% 0.6518 15 76% 81%
0 32 66 25 73% 75% 0.5731 71%
0 32 65 62% 68% 69% 0.48138 122
-25 66 56% 58% 0.51-13 31 61 74%
35 95 40 - - 75% 0.6719 16
35 95 66 26 - - 69% 0.6031
35 95 - - 0.5164 136 125 54%
* Data not certified by HVI.
1108608E
Fan curve not certified by HVI.

Produktspezifikationen

Marke: VänEE
Kategorie: Airco
Modell: V160E65RT

Brauchst du Hilfe?

Wenn Sie Hilfe mit VänEE V160E65RT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Airco VänEE

Bedienungsanleitung Airco

Neueste Bedienungsanleitung für -Kategorien-