Trotec DS-Serie Bedienungsanleitung
Trotec
Sonstige Klimatisierung
DS-Serie
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Trotec DS-Serie (12 Seiten) in der Kategorie Sonstige Klimatisierung. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/12
TRT-BA-EKP-DS-/DH-SERIE-TC220628TTRT02-002-EN
External condensate pump
DS/DH Series
EN
ORIGINAL INSTRUCTIONS
EXTERNAL CONDENSATE PUMP
2 EN
external condensate pump External condensate pump DS/DH series
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................3
Transport and storage...........................................................4
Assembly and installation.....................................................5
Errors and faults....................................................................7
Maintenance ..........................................................................8
Technical annex.....................................................................9
Disposal ...............................................................................11
Notes regarding the instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions via the
following link:
EKP DS/DH
https://hub.trotec.com/?id=42513
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Do not cover the device during operation.
• Do not sit on the device.
• This device is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.
• Insert the mains plug into a properly fused mains socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
EN 3
external condensate pump External condensate pump DS/DH series
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Disconnect the power cable from the mains socket when
the device is not in use.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Never insert any objects or limbs into the device.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
• Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.
Intended use
Only use the device as a condensate pump in combination with
dehumidifiers. The device was designed for continuous
operation and is suited for the following pumping media:
• clear water
• slightly chlorinated or salted water
Improper use
• Do not place the device on wet or flooded ground.
• The device is not suitable for pumping potable water.
• The device is not suitable for increasing the pressure of
existing water supply networks.
• The device must not be used for aggressive, abrasive,
caustic, combustible or explosive pumping media.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands
of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
2. Do not reconnect a defective device to the mains.
Information about the device
Device description
When combined with a dehumidifier, the external condensate
pump can be used for failure-free continuous operation. With its
robust and corrosion-resistant housing it is particularly suited for
combination with the pool dehumidifiers of Trotec's DS and
DHseries, but can also be used with other dehumidifiers without
a hitch.
The fully automatic condensate pump can be installed quickly and
without difficulty and is specifically designed for pumping off
condensation water. It is particularly suited for applications with
long water discharge distances or for a longer permanent drying
of unattended rooms.
The power for the dehumidifier should be supplied via the
condensate pump. To do so, either use the socket of the
condensate pump(6), or directly wire the dehumidifier to the
pump via the connector for direct supply(5). For direct supply, the
internal plug connections and a female connector are ready to
install.
If the condensate cannot be discharged from the dehumidifier
(e.g. due to a clogged line), the condensate pump will switch off
the connected dehumidifier automatically. Once the fault has
been cleared, the dehumidifier will be switched back on (see also
Errors and faults).
The pump is suitable for a pump height of up to 4.3metres.
The device can be mounted to the wall or positioned on the floor
for operation.
Produktspezifikationen
Marke: | Trotec |
Kategorie: | Sonstige Klimatisierung |
Modell: | DS-Serie |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Trotec DS-Serie benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Sonstige Klimatisierung Trotec
14 August 2024
7 August 2024
Bedienungsanleitung Sonstige Klimatisierung
- Sonstige Klimatisierung Bosch
- Sonstige Klimatisierung AEG
- Sonstige Klimatisierung Siemens
- Sonstige Klimatisierung ATAG
- Sonstige Klimatisierung Gira
- Sonstige Klimatisierung Inventum
- Sonstige Klimatisierung Polti
- Sonstige Klimatisierung Vasco
- Sonstige Klimatisierung Vaillant
- Sonstige Klimatisierung Duux
- Sonstige Klimatisierung Honeywell
- Sonstige Klimatisierung Remko
- Sonstige Klimatisierung Junkers
- Sonstige Klimatisierung Zehnder
- Sonstige Klimatisierung Theben
- Sonstige Klimatisierung Stiebel Eltron
- Sonstige Klimatisierung Xavax
- Sonstige Klimatisierung Dimplex
- Sonstige Klimatisierung Buderus
- Sonstige Klimatisierung Edimax
- Sonstige Klimatisierung Argo
- Sonstige Klimatisierung Salus
- Sonstige Klimatisierung SMA
- Sonstige Klimatisierung EasyMaxx
- Sonstige Klimatisierung Elektrobock
- Sonstige Klimatisierung Oregon Scientific
- Sonstige Klimatisierung Elco
- Sonstige Klimatisierung Frigicoll
- Sonstige Klimatisierung HRSolar
- Sonstige Klimatisierung Kaysun
- Sonstige Klimatisierung Mastervolt
- Sonstige Klimatisierung MCZ
- Sonstige Klimatisierung Nefit
- Sonstige Klimatisierung Nuon
- Sonstige Klimatisierung Plugwise
- Sonstige Klimatisierung Premix
- Sonstige Klimatisierung Progenion
- Sonstige Klimatisierung RAINBIRD
- Sonstige Klimatisierung Renusol
- Sonstige Klimatisierung Riello
- Sonstige Klimatisierung Skytech
- Sonstige Klimatisierung Sungevity
- Sonstige Klimatisierung Technea
- Sonstige Klimatisierung ACV
- Sonstige Klimatisierung VC Trade
- Sonstige Klimatisierung Ygnis
- Sonstige Klimatisierung A.O. Smith
- Sonstige Klimatisierung Amfra
- Sonstige Klimatisierung AGPO
- Sonstige Klimatisierung AWB
- Sonstige Klimatisierung Brink
Neueste Bedienungsanleitung für -Kategorien-
5 Oktober 2024
20 September 2024
19 September 2024
18 September 2024
Ygnis TOTALECO TURBO Diversen klimaatbeheersing Bedienungsanleitung
14 September 2024
27 August 2024
27 August 2024
27 August 2024
26 August 2024
26 August 2024