Tripp Lite SmartRack SRCOOL33K Bedienungsanleitung

Tripp Lite Klimaanlage SmartRack SRCOOL33K

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tripp Lite SmartRack SRCOOL33K (64 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/64
1
Table of Contents
1. Introduction 2
2. Important Safety Instructions 2
3. Features 3
4. Specifications 4
5. Operation 5
6. Troubleshooting 11
7. Preventive Maintenance 12
8. Storage and Service 14
9. Warranty & Warranty Registration 15
Español 17
Francais 33
Русский 49
Self-Contained
Air Conditioning Unit
Models: SRCOOL33K, SRXCOOL33K
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2013 Tripp Lite. All trademarks are the sole property of their respective owners.
WARRANTY
REGISTRATION
Register online today for a chance
to win a FREE Tripp Lite product
www.tripplite.com/warranty
13-11-214-93-3139.indb 1 12/10/2013 10:18:51 AM
2
1. Introduction
2. Important Safety Instructions
Tripp Lite’s SRCOOL33K/SRXCOOL33K is a self-contained air conditioning unit housed in a standard 42U enclosure. The SRCOOL33K/
SRXCOOL33K is optimized for general computer room cooling or supplemental cooling in a large server room. It features an inverter-driven
DC (direct current) variable-speed compressor that delivers high-efciency precision cooling. This helps maintain set temperature without the
traditional method of wasteful On/Off cycling.
A menu-driven, multi-line LCD screen provides on-site monitoring and control of various operating conditions. These operational conditions
can also be monitored and controlled remotely via SNMP, Web, telnet or Modbus.
SAVE THESE INSTRUCTIONS
All sections of this owner’s manual contain instructions and warnings that must be followed during the operation of the products described
in this manual. Read ALL instructions before attempting to operate these products. Failure to comply may invalidate the warranty and cause
serious property damage and/or personal injury.
• Prior to use, the individual user must determine whether this device is suitable, adequate or safe for the use intended. Since individual
applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability ortness of this
device for any specific application.
• The cooling unit operates under pressure. Observe proper safety precautions when operating or servicing the unit.
• Do not operate the unit with any cover, guard, door, or panel removed unless the instructions indicate otherwise.
• Do not run cabling or service utilities in front of the fan outlets.
• Connect the unit directly to a grounded AC power outlet. Failure to do so may cause electric shock or fire. Note: If the unit is hardwired,
the user should ground it according to local regulations.
• The power supply for the unit must be rated as specied on the units nameplate.
• Never modify the unit’s plug or use an adapter if the unit is equipped with an input power cord.
• Comply with all local and national wiring and safety regulations applicable where the unit will be installed, e.g. The National Electric Code
(NEC) in the United States.
• On models with an input cord, never use the cord as a means to turn the unit on or off. A serious electric shock may occur. Always use the
control panel to power the unit on or off.
• Always turn the unit off and disconnect it from the mains input source by unplugging the unit or opening the mains circuit breaker before
performing maintenance.
• Before connecting the unit to a dedicated drainage system, turn it off and unplug it.
• Maintenance should be performed by trained personnel only.
• Do not use thinners, alcohol, detergents or abrasive brushes to clean the unit’s cabinet. These may damage the cabinet.
• Do not operate the unit without the air filter. This may cause dust accumulation that can damage the unit.
• Do not attempt to operate the unit in any room with inadequate air circulation. There must be adequate airflow to the condenser.
• Do not place objects on top of the unit.
• Prior to operation, ensure that:
• The unit has been properly installed in accordance with the procedures detailed in the Installation Manual
• There is no evidence of damage to the unit
• The unit is level and stabilized
• The clearance around the cooling unit complies with local and national codes and regulations as well as the installation manual
• Warning! Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
13-11-214-93-3139.indb 2 12/10/2013 10:18:51 AM
3
3. Features
• 33,000 BTU of cooling power
• Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling
adjustments
• Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads
• Self-contained, zero-maintenance unit atomizes condensate and expels it through the exhaust air stream—no oor drain, water collection
tank, external condenser, refrigerant piping, ductwork or plumbing required when used in typical conditions
• Convenient LCD control panel and network interface enable local and remote monitoring and control of temperature, fan speed, alarms
and logging via front-panel buttons, SNMP, Web, telnet or Modbus
• Row-based airflow path maximizes hot-aisle/cold-aisle efficiency and cooling predictability by supplying cold intake air high in the cold aisle
and removing hot equipment exhaust air low from the hot aisle
• Eco-friendly R410a refrigerant meets environmental standards worldwide
• Nominal 208-240V AC Input, 50/60 Hz frequency compatibility
13-11-214-93-3139.indb 3 12/10/2013 10:18:51 AM


Produktspezifikationen

Marke: Tripp Lite
Kategorie: Klimaanlage
Modell: SmartRack SRCOOL33K
Breite: 599.4 mm
Tiefe: 1084.6 mm
Gewicht: 253100 g
Produktfarbe: Schwarz
Höhe: 1991.4 mm
Verpackungsbreite: 650.2 mm
Verpackungstiefe: 1140.5 mm
Verpackungshöhe: 2143.8 mm
Paketgewicht: 285760 g
Warentarifnummer (HS): 8415.10.3080
Ursprungsland: China
Anzahl Produkte pro Versandkarton: 1 Stück(e)

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite SmartRack SRCOOL33K benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Tripp Lite

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-