Tripp Lite SmartPro SMART750USBTAA Bedienungsanleitung
Tripp Lite
UPS
SmartPro SMART750USBTAA
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Tripp Lite SmartPro SMART750USBTAA (24 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war fĂĽr 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/24
Owner’s Manual
1111 W. 35th Street Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • www.tripplite.com
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
Storage & Service 7
Warranty Registration 7
SmartPro®USB UPS Systems
Copyright © 2006 Tripp Lite. All rights reserved. SmartPro
®is a registered trademark of Tripp Lite.
Español 8
Français 16
WARRANTY
REGISTRATION:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
Not suitable for mobile applications.
200609033 93-2616 SMARTUSB UPS OM.qxd 9/14/2006 3:01 PM Page 1
Important Safety Instructions
2
UPS Location Warnings
• Install the UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, keep the indoor temperature between between 32º F and 104º F
(0Âş C and 40Âş C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect the UPS directly to a properly grounded AC power outlet. Do not plug the UPS
into itself; this will damage the UPS.
• Do not modify the UPS plug, and do not use an adapter that would eliminate the ground
connection.
• Do not use extension cords to connect the UPS to an AC outlet. The warranty will be
void if anything other than Tripp Lite surge suppressors are used to connect the UPS
to an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life-support applications in which a malfunction
or failure of a Tripp Lite UPS System could cause failure or significantly alter the
performance of a life-support device.
• Do not connect surge suppressors or extension cords to the output of the UPS. This may
damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• The UPS does not require routine maintenance. Do not open the UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burns from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the
UPS or batteries. Do not short or bridge the battery terminals with any object. Use tools
with insulated handles. Battery replacement should be performed only by authorized
service personnel using the same number and type of batteries (Sealed Lead-Acid). The
batteries are recyclable. Refer to your local codes for disposal requirements or in the
USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-822-8837) or visit
www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS
System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at
www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery
for your UPS.
• Do not attempt to add external batteries.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings will
void the warranty.
200609033 93-2616 SMARTUSB UPS OM.qxd 9/14/2006 3:01 PM Page 2
3
Quick Installation
Connect the UPS to
an electrical outlet.
Make sure the outlet does not share a circuit
with a heavy electrical load such as an air
conditioner or refrigerator.
Plug a computer, monitor
and/or other equipment into
the UPS system.
The UPS is designed to support only
computer equipment. Connecting high power
draw equipment such as household appliances
or laser printers to outlets providing UPS
battery backup will overload the UPS. Special
outlets (clearly labeled on the rear panel)
provide surge-only (not battery backup)
protection designed for laser printers and
other high power draw equipment.
“UPS/Surge” receptacles are used to provide
connected equipment with AC line power
during normal operation and battery power
during blackouts and brownouts. They also
protect equipment against damaging surges
and line noise. Connect the computer and
monitor to the “UPS/Surge” receptacles.
Select UPS Operating Mode.
Press the ON/OFF button to toggle the UPS
between the ON (“ ” LED lit) and the OFF
(“ ” LED not lit) modes.
3
2
1
NORM DELAY
1
2
3
200609033 93-2616 SMARTUSB UPS OM.qxd 9/14/2006 3:01 PM Page 3
Produktspezifikationen
Marke: | Tripp Lite |
Kategorie: | UPS |
Modell: | SmartPro SMART750USBTAA |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Tripp Lite SmartPro SMART750USBTAA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS Tripp Lite
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
2 Oktober 2024
29 September 2024
19 September 2024
10 September 2024
8 September 2024
30 August 2024
16 August 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS APC
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung fĂĽr -Kategorien-
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
11 Oktober 2024
5 Oktober 2024